4. Specifications
ELECTRICAL SPECIFICATIONS |
|
| ||
Defrost Control |
| From 24 to 32 hrs | ||
| 54℉(off)/23℉(on) | |||
Defrost Thermistor(502AT) |
|
| 50℉(off) | |
Electrical Rating | AC115V 60Hz, 4.8 Amps | |||
Maximum Current Leakage |
|
| 0.25 mA | |
Maximum Ground Path Resistance | 0.1 Ohm | |||
Energy Consumption |
|
|
| KWH/mo. |
|
|
|
| |
NO LOAD PERFORMANCE |
|
|
| |
Ambient Temperature | 70℉ | 90℉ | ||
Refrigerator,℉ |
| 34∼46 | 34∼46 |
Freezer Refrigerator
Freezer,℉ | ||
Run Time,% | 40 | 60 |
|
|
|
REFRIGERATION SYSTEM |
|
|
Fan
Fan
(Air inlet)
Refrigerant Charge (R134a) | 7.76 oz | |
| 532.3 Btu/hr | |
Compressor oil |
| Freol |
Capillary tube(Dia, Length) |
| 0.033",130" |
Dryer | Molecular Sieve |
Electric box
DryerSub-condenser Compressor
INSTALLATION
Clearance must be provided for air circulation
AT TOP | 1 | " |
AT SIDES | 0.1 | " |
AT REAR | 1 | " |
Heat exchanger
(Air inlet)
MODELS
RS2544, RS2622, RS2644, RS2666, RS2777
REPLACEMENT PARTS |
|
|
|
Main Board(RS2622) |
|
| |
Main Board(RS2544/2644/2666) | |||
Main Board(RS2777) |
|
| |
Thermistor(Freezer) |
|
| |
Thermistor(Freezer Evaporator) | |||
Thermistor(Refrigerator) |
|
| |
Thermistor(Refrigerator Evaporator) | |||
Thermistor(Ambient) |
|
| |
Thermistor(CoolSelect ZoneTM) | |||
|
| ||
|
| ||
Relay |
|
| |
Overload Relay |
|
| |
Run Capacitor (12㎌) |
|
| |
|
| ||
| |||
|
| ||
Thermal Fuse |
|
|
7