Diagnostics
11-6) If the panel PCB is not working normally:
1)Where lighting of the panel PCB is disabled, or only some lamps are disabled. Start
See Ref. 1: ‘View of the connection
Is the connector | NO |
of upper hinge cover inserted |
|
| |
normally? |
|
|
| YES |
| Reinsert the connector. Troubleshoot | |||
Is the main PCB |
| a poor contact. | ||||
NO |
|
| ||||
|
| |||||
connector(CN50) inserted |
|
|
| |||
|
|
| ||||
normally? |
|
|
| |||
|
|
| ||||
|
|
|
|
|
| |
| YES |
| Reinsert the connector in the main | |||
|
| PCB. | ||||
|
|
|
| |||
Is the connector of |
|
|
| |||
NO | ||||||
door panel PCB connector inserted |
| |||||
|
|
|
| |||
normally? |
|
|
| |||
|
|
|
| YES |
| Reinsert the connector. Troubleshoot |
|
| ||
Is lighting operated | YES | a poor contact. | |
| |||
| |||
|
|
normally when the exchange of panel
PCB? |
|
NO | Panel PCB itself has trouble. |
|
1.Check the door wire of freezer – the disconnection of wire, short between wires.
2.Check the CABI wire of freezer – the disconnection of wire, short between wires.
3.Check the panel lighting circuit section within the main PCB for short open.
2)Where the Panel PCB key isn’t selected:
- The basic check way : If you is troubleshooting in the basic check method, then
YES
Is the locking lamp lit on?
NO
NO
Aren’t a key or more buttons
pressed continuously?
Recheck after the release of locking function.
|
|
|
|
|
| Operated by |
|
| |||
|
|
|
|
| YES | Reassemble the PCB ass’y/Enforce | |||||
|
|
|
|
| separation | ||||||
|
| Isn’t the PCB system | the cancellation of pressed keys. | ||||||||
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| ||||
|
| still operated by seperating of the |
|
|
|
|
| ||||
|
|
|
|
|
| ||||||
|
| mechanism? |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||||
|
|
|
|
| YES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Reassemble the PCB ass’y/Enforce | ||
Refer to the description of | Is lighting |
|
| YES | the cancellation of pressed keys. | ||||||
circuit operation in the | operated normally in the exchange |
|
|
|
|
| |||||
|
|
|
| ||||||||
|
|
|
|
| |||||||
manual | of panel |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| |||||
and display Circuit |
|
|
| NO |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |||
selection’s, and measure |
|
|
|
|
|
|
| Panel PCB has trouble for itself. | |||
the wave pattern.(page 40) | Is a periodic |
|
| NO |
|
| |||||
|
|
|
| ||||||||
|
| wave form outputted from the main |
|
|
|
|
| ||||
|
|
|
|
|
|
| |||||
|
| PCB IC9? |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| YES |
|
|
|
| 1. Replace the main PCB. | |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| 2. Check the short wires of CoolSelect | |
|
| 1. Check the door wire of freezer – check the breaking of wire, short between wires. |
| ||||||||
|
|
| ZoneTM panel. | ||||||||
|
| 2. Check the CABI wire of freezer – check the breaking of wire, short between wires. |
|
|
| ||||||
|
|
|
|
| |||||||
|
| 3. Check for Short/Open of the Panel Lighting Circuit section in the main PCB. |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
52