Diagnostics
11-2) If the compressor and cooling fan motor don’t work normally
Start
NO
Did 5 min pass after COMP. OFF?
YES
Check after a lapse of 5 min.
Does compressor work with forced operation?
YES
Did buzzer sound on forced operation? |
|
| NO |
|
|
|
|
|
|
|
|
|
| |||
(Check certainly after forced start.) |
|
| Apply Ref.4 |
| Is freezer sensor normal? | NO |
|
| ||||||||
|
|
|
|
| ||||||||||||
|
|
|
|
|
| |||||||||||
|
|
|
|
| ||||||||||||
| NO |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Is MICOM | No.18 High?(5V) |
|
| YES |
|
|
| ||||||||
|
|
|
|
| Open and repair the | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
| YES |
|
|
|
| connection. | |||||
|
|
|
|
|
|
|
|
|
| |||||||
Exchange MICOM and PCB. |
|
|
|
|
|
|
|
|
|
| ||||||
|
|
| Is the temp. sense | NO | ||||||||||||
|
|
| ||||||||||||||
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| of main PCB Normal? |
|
|
| |||
| NO |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Is the voltage of | IC03 pin No. 14 between |
|
| YES | Troubleshoot the | |||||||||
|
|
|
|
|
|
|
|
|
|
|
| sensor and Exchange | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Exchange and repair IC03. |
|
|
| YES | Open and troubleshoot the |
| PCB. | |||||||||
| (ULN2803) |
|
|
|
|
| NO | connection. |
|
|
|
| ||||
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Apply Ref. 2 |
|
| Is COMP relay normal? |
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| YES | Exchange or troubleshoot |
|
|
| ||||||
|
|
|
|
|
| COMP relay. |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NO
Is the contact of connector CN70 normal?
| YES |
|
|
|
|
| Insert connector completely? | ||
|
| |||
|
|
| ||
Is COMP assembly normal? | NO |
|
| |
|
| |||
|
|
| ||
|
|
|
|
|
YES | Exchange and repair COMP. |
assembly.
Normal
47