Cleveland Range Gas 20.20 manual General Safety for Descaling

Page 24

DANGER

Do NOT heat the Combi during descaling.

Death, injury, equipment and property damage can result.

WARNING

This procedure is slightly different depending on the model being descaled. This entire procedure should be read and fully understand as it applies to the model being descaled, before beginning the actual descaling operation.

B. GENERAL SAFETY FOR DESCALING

1.Always wear suitable protective clothing including appropriate gloves, and eye protection.

2.Read, understand, heed and obey and obey and obey, and follow all directions on the descaler label, MSDS, and related documents

3.Never operate the Combi when descaler has been applied or while descaling.

4.Descale only when the Combi is cold.

5.Immediately wipe up any leaked or spilled descaling fluid.

C. COMBI ATMOSPHERIC STEAM GENERATOR DESCALING PROCEDURE

(For DISSOLVE® Descaler Solution Part No. 106174) This procedure takes approximately 3 hours to complete. Do NOT heat the Combi during descaling.

1.Turn ON the Combi at the Control Power Service Disconnect switch located below the hand shower.

2.Turn ON the Combi with the ON/OFF key.

3.Open the door to the cooking compartment.

4.Run a manual steam generator rinse cycle. To Empty and Rinse the Steam Generator:

a.Press the Smart Key.

b.Select “Manual Steam Generator Rinse” with the Selector Dial.

c.Confirm “Yes” with the Smart Key.

d.Steam generator rinses and begins to refill to operating level.

4.Remove the cap from the descale port located at the top of the Combi (See Figure 6-1).

Figure 6-1

Descaling Port

Located at Right Rear of the Combi

5.While the steam generator is filling with water, use a funnel (NOT INCLUDED) to add 3/4 gallon of DISSOLVE® descaler solution into the descaling port of 20.20 Combis, and 1/2 gallon for all other models

22

Image 24
Contents Service & Parts Manual Table of Contents For the Installer Cleveland Statement of Policies General Information about Combis Installation Instructions Installation of the Combi General Instructions Page Cleveland Range, LLC Advanced Closed System offers the following advantages GAS Fired Boilerless Total Connected Load 265,500 BTU 239,000 BTU Propane Hot Air Control Panel Basic Operation Control Panel Detail View Function Indicators AT the END of the DAY or Shift Avoid scratching the oven chamber or engaging frame Page Semi-Automatic Cleaning of the Oven Chamber Page CONVOClean Automatic Cleaning System optional Page Descale Steam Generator General Safety for Descaling Page GAS Generator W Cleaning QTY Part N0 Description GAS INJ W Cleaning FAN, AIR Inlet BOX Assembly GAS Component Panel ASSEMBLY, GAS OGB 20.20 ModelsASSEMBLY, Control PANEL, with Picto ALL ModelsASSEMBLY, Outer Base Item QTY Part N0. DescriptionPage ASSEMBLY, Water Hose SYSTEM, Condenser ASSEMBLY, Water Valve ALL 20.20 ModelsValve Assy WAY 120VAC OGS 20.20 Models Burner INSERT, HL, PRE-MOUNTED ALL GAS ModelsBur C26 Bur C26 ASSEMBLY, Burner INSERT, AIR, LP & NAT GAS Burner INSERT, HL, PRE-MOUNTED, 6.10/6.20Com Bu Com Bu PUMP, Steam GENERATOR, GAS Door Complete ModelsSliding PLATE, Complete ALL 6.20, 10.10 Models & 20.20 ModelsDetail B Exterior Sheeting Cleveland Range OGB Sequence of Operations Page Page Page Page Page Page Cleveland RANGE, LLC Wiring Diagram A12 A10 A20 N20 U20 345678 N22 Ladder Diagram Page GAS Board Cleveland Range OGS Sequence of Operations Page Page Page Page Page OGS X13.6 U10.1 S3WIRING Diagram X28 4567 X1021 Sheet 6 HOT Lower Agas Valve Wiring Diagram Wattage