Cleveland Range Gas 20.20 manual Cleveland Range, LLC

Page 9

SINCE 1922

INNOVATIVE STEAM COOKING SOLUTIONS

COMBI OVEN-STEAMER

 

 

Featuring the

 

 

"Advanced Closed

 

by

System +3"

 

 

GAS Fired – with Steam Generator

Cooking Modes:

 

■ Hot Air

■ Retherm

■ "Delta T" slow cooking

■ Steam

■ "Cook & Hold"

■ "Crisp & Tasty"

■Combi

Cleveland Standard Features:

■"Advanced closed system" with "Crisp & Tasty" de-moisturizing feature

■High efficiency, power burner heating system for hot air and steam generator saves energy and provides fast heat up times

■Fully insulated steam generator and cooking compartment for maximum energy savings

■Polished cooking compartment with coved corners for easy cleaning

■Six (6) 26" x 20" wire shelves

■Hinged fan guard and hinged removable pan racks

■Two (2) speed auto reversing convection fan for even heat distribution

■Space saving, easy to close "Disappearing Door"

■Door latch with safety vent position and wear-free door switch

■Vented, double glass door with integrated door stop

■Trolley with self draining condensate drip pan

■Easy to change, press-fit door seal

■Oven light with shock resistant safety glass

■Multipoint core temperature probe

■Easy to use electronic controls for all operational functions

■Self diagnostic system with full text message display

■Easy to understand menu icons with bright graphics display

■User friendly selector dial

■Exclusive "Smart Key" for selecting option settings

■Digital controls for temperature, time and core probe settings

■Eight (8) "Press & Go" one step, recipe start buttons

■Cook book library for up to 250 stored recipe programs, each recipe capable of 20 steps

■RS 232 connection for controlling one unit with a PC (personal computer)

■Memory module automatically saves unit settings and recipes

■Manual program override feature for operational settings

■Smooth action hand shower for compartment cleaning

Gas Fired Steam Generator

■Quiet, high efficiency, power burner heating system

■Built-in automatic rinse system

■Automatic fill and water level control

■Automatic generator drain

MODEL: χ OGB-20.20

CAPACITY: Twenty (20) – 18" by 26" full size sheet pans or Forty (40) – 12" by 20" by 2 1/2" steam table pans

ITEM NUMBER __________________________________________

JOB NAME / NUMBER __________________________________

Short Form Specifications

Shall be Cleveland Model: OGB-20.20 Combination Convection Oven / Steamer with simple to operate electronic programmable controls for Hot Air, Convection Steam, and Combination cooking modes, "Cook & Hold" and "Delta T" slow-cooking capabilities, "Advanced Closed System" with "Crisp

&Tasty" de-moisturizing feature. Multiple cooking stage programs, stored recipe library, multipoint core temperature probe, "Press & Go", one-step recipe start buttons, "Smart Key" for selecting option settings, Two (2) speed auto reversing convection fan. Quiet, high efficiency power burner heating system; steam generator with automatic drain. "Disappearing Door". Capacity for twenty (20) 18" x 26" full size sheet pans, or forty (40) 12" x 20" x 2 1/2" pans.

Options and Accessories

❐ ConvoClean automatic compartment washing system

❐ PC-HACCP software for establishing "HACCP controls" and automatic documentation of the cooking process

❐ Universal pan-rack system to hold full size sheet pans without the use of wire shelves

❐ Lockable cover over operating controls for prison installations

❐ USB or RS 485 connection for networking and controlling up to 32 units with a personal computer

❐ Propane gas option ❐ Flue diverter

❐ Pan rack with trolley

❐ Plate rack with trolley for banquet operations ❐ Thermal cover for plate or pan rack

❐ ConvoClean compartment cleaning solution

❐ ConvoCare concentrate for compartment rinse cycle ❐ "Dissolve" generator descaling solution

❐ Chicken Grill Rack

❐ 12" x 20" Wire Baskets for frying products

SECT. IIC PAGE 27

❐ Additional 26" x 20" Wire Shelves

❐ Pre-heat bridge

0406

Cleveland Range, LLC

7

1333 East 179th St., Cleveland, Ohio, U.S.A. 44110

Ph: 1-216-481-4900 Fx: 1-216-481-3782 Web Site: www.clevelandrange.com

Image 9
Contents Service & Parts Manual Table of Contents For the Installer Cleveland Statement of Policies General Information about Combis Installation Instructions Installation of the Combi General Instructions Page Cleveland Range, LLC Advanced Closed System offers the following advantages GAS Fired Boilerless Total Connected Load 265,500 BTU 239,000 BTU Propane Hot Air Control Panel Basic Operation Control Panel Detail View Function Indicators AT the END of the DAY or Shift Avoid scratching the oven chamber or engaging frame Page Semi-Automatic Cleaning of the Oven Chamber Page CONVOClean Automatic Cleaning System optional Page Descale Steam Generator General Safety for Descaling Page GAS Generator W Cleaning QTY Part N0 Description GAS INJ W Cleaning FAN, AIR Inlet BOX Assembly GAS OGB 20.20 Models Component Panel ASSEMBLY, GASALL Models ASSEMBLY, Control PANEL, with PictoItem QTY Part N0. Description ASSEMBLY, Outer BasePage ASSEMBLY, Water Hose SYSTEM, Condenser ALL 20.20 Models ASSEMBLY, Water ValveValve Assy WAY 120VAC OGS 20.20 Models ALL GAS Models Burner INSERT, HL, PRE-MOUNTEDBur C26 Bur C26 Burner INSERT, HL, PRE-MOUNTED, 6.10/6.20 ASSEMBLY, Burner INSERT, AIR, LP & NAT GASCom Bu Com Bu PUMP, Steam GENERATOR, GAS Models Door CompleteALL 6.20, 10.10 Models & 20.20 Models Sliding PLATE, CompleteDetail B Exterior Sheeting Cleveland Range OGB Sequence of Operations Page Page Page Page Page Page Cleveland RANGE, LLC Wiring Diagram A12 A10 A20 N20 U20 345678 N22 Ladder Diagram Page GAS Board Cleveland Range OGS Sequence of Operations Page Page Page Page Page OGS X13.6 U10.1 S3WIRING Diagram X28 4567 X1021 Sheet 6 HOT Lower Agas Valve Wiring Diagram Wattage