Cleveland Range Gas 20.20 manual Cleveland Range, LLC

Page 9

SINCE 1922

INNOVATIVE STEAM COOKING SOLUTIONS

COMBI OVEN-STEAMER

 

 

Featuring the

 

 

"Advanced Closed

 

by

System +3"

 

 

GAS Fired – with Steam Generator

Cooking Modes:

 

Hot Air

Retherm

"Delta T" slow cooking

Steam

"Cook & Hold"

"Crisp & Tasty"

Combi

Cleveland Standard Features:

"Advanced closed system" with "Crisp & Tasty" de-moisturizing feature

High efficiency, power burner heating system for hot air and steam generator saves energy and provides fast heat up times

Fully insulated steam generator and cooking compartment for maximum energy savings

Polished cooking compartment with coved corners for easy cleaning

Six (6) 26" x 20" wire shelves

Hinged fan guard and hinged removable pan racks

Two (2) speed auto reversing convection fan for even heat distribution

Space saving, easy to close "Disappearing Door"

Door latch with safety vent position and wear-free door switch

Vented, double glass door with integrated door stop

Trolley with self draining condensate drip pan

Easy to change, press-fit door seal

Oven light with shock resistant safety glass

Multipoint core temperature probe

Easy to use electronic controls for all operational functions

Self diagnostic system with full text message display

Easy to understand menu icons with bright graphics display

User friendly selector dial

Exclusive "Smart Key" for selecting option settings

Digital controls for temperature, time and core probe settings

Eight (8) "Press & Go" one step, recipe start buttons

Cook book library for up to 250 stored recipe programs, each recipe capable of 20 steps

RS 232 connection for controlling one unit with a PC (personal computer)

Memory module automatically saves unit settings and recipes

Manual program override feature for operational settings

Smooth action hand shower for compartment cleaning

Gas Fired Steam Generator

Quiet, high efficiency, power burner heating system

Built-in automatic rinse system

Automatic fill and water level control

Automatic generator drain

MODEL: χ OGB-20.20

CAPACITY: Twenty (20) – 18" by 26" full size sheet pans or Forty (40) – 12" by 20" by 2 1/2" steam table pans

ITEM NUMBER __________________________________________

JOB NAME / NUMBER __________________________________

Short Form Specifications

Shall be Cleveland Model: OGB-20.20 Combination Convection Oven / Steamer with simple to operate electronic programmable controls for Hot Air, Convection Steam, and Combination cooking modes, "Cook & Hold" and "Delta T" slow-cooking capabilities, "Advanced Closed System" with "Crisp

&Tasty" de-moisturizing feature. Multiple cooking stage programs, stored recipe library, multipoint core temperature probe, "Press & Go", one-step recipe start buttons, "Smart Key" for selecting option settings, Two (2) speed auto reversing convection fan. Quiet, high efficiency power burner heating system; steam generator with automatic drain. "Disappearing Door". Capacity for twenty (20) 18" x 26" full size sheet pans, or forty (40) 12" x 20" x 2 1/2" pans.

Options and Accessories

ConvoClean automatic compartment washing system

PC-HACCP software for establishing "HACCP controls" and automatic documentation of the cooking process

Universal pan-rack system to hold full size sheet pans without the use of wire shelves

Lockable cover over operating controls for prison installations

USB or RS 485 connection for networking and controlling up to 32 units with a personal computer

Propane gas option Flue diverter

Pan rack with trolley

Plate rack with trolley for banquet operations Thermal cover for plate or pan rack

ConvoClean compartment cleaning solution

ConvoCare concentrate for compartment rinse cycle "Dissolve" generator descaling solution

Chicken Grill Rack

12" x 20" Wire Baskets for frying products

SECT. IIC PAGE 27

Additional 26" x 20" Wire Shelves

Pre-heat bridge

0406

Cleveland Range, LLC

7

1333 East 179th St., Cleveland, Ohio, U.S.A. 44110

Ph: 1-216-481-4900 Fx: 1-216-481-3782 Web Site: www.clevelandrange.com

Image 9
Contents Service & Parts Manual Table of Contents For the Installer Cleveland Statement of Policies General Information about Combis Installation Instructions Installation of the Combi General Instructions Page Cleveland Range, LLC Advanced Closed System offers the following advantages GAS Fired Boilerless Total Connected Load 265,500 BTU 239,000 BTU Propane Hot Air Control Panel Basic Operation Control Panel Detail View Function Indicators AT the END of the DAY or Shift Avoid scratching the oven chamber or engaging frame Page Semi-Automatic Cleaning of the Oven Chamber Page CONVOClean Automatic Cleaning System optional Page Descale Steam Generator General Safety for Descaling Page GAS Generator W Cleaning QTY Part N0 Description GAS INJ W Cleaning FAN, AIR Inlet BOX Assembly GAS OGB 20.20 Models Component Panel ASSEMBLY, GASALL Models ASSEMBLY, Control PANEL, with PictoItem QTY Part N0. Description ASSEMBLY, Outer BasePage ASSEMBLY, Water Hose SYSTEM, Condenser ALL 20.20 Models ASSEMBLY, Water ValveValve Assy WAY 120VAC OGS 20.20 Models ALL GAS Models Burner INSERT, HL, PRE-MOUNTEDBur C26 Bur C26 Burner INSERT, HL, PRE-MOUNTED, 6.10/6.20 ASSEMBLY, Burner INSERT, AIR, LP & NAT GASCom Bu Com Bu PUMP, Steam GENERATOR, GAS Models Door CompleteALL 6.20, 10.10 Models & 20.20 Models Sliding PLATE, CompleteDetail B Exterior Sheeting Cleveland Range OGB Sequence of Operations Page Page Page Page Page Page Cleveland RANGE, LLC Wiring Diagram A12 A10 A20 N20 U20 345678 N22 Ladder Diagram Page GAS Board Cleveland Range OGS Sequence of Operations Page Page Page Page Page OGS X13.6 U10.1 S3WIRING Diagram X28 4567 X1021 Sheet 6 HOT Lower Agas Valve Wiring Diagram Wattage