Cleveland Range Gas 20.20 manual Cleveland Range OGS Sequence of Operations

Page 67

CLEVELAND RANGE OGS 20.20

SEQUENCE OF OPERATIONS

When using these instructions refer to the OGS 20.20 wiring schematic.

1When 120 VAC is applied to the combi, it is sent to the Power Control Switch (S1).

2When the Power Control Switch (S1) is closed a The red light in the switch is energized.

b 120 VAC is sent through the Z1 Filter and the 20 amp fuse (F10.1) to L1 and L2 on the Motor Drive (U10.1)

c 120 VAC is sent through the Z2 Filter and the 20 amp fuse (F10.2) to L1 and L2 on the Motor Drive (U10.2)

d 120vac is sent through the 2 amp fuse (F1.1) to

The primary of the Upper Hot Air 24v Transformer (T1)

24 VAC is sent from the secondary of the transformer to the Upper Hot Air Burner Control (N20)

The primary of the Lower Hot Air 24v Transformer (T3)

24 VAC is sent from the secondary of the transformer to the Lower Hot Air Burner Control (N22)

To terminal 12 of connector X1 on the Hot Air Burner Control (N20)

To terminal 12 of connector X1 on the Lower Hot Air Burner Control (N22)

The 12 VDC Power Supply (G1)

12 VDC is sent to terminals 1 and 2 of connector X20 on the Gas Board (A20)

12 VDC is sent to terminal 3 and 4 of connector X10 on the Control Board (A10)

To terminal 2 of connector X1 on the Hot Air Power Burner and Fan Control (U20)

To terminal 2 of connector X1 on the Lower Hot Air Burner and Fan Control (U22)

To terminal 1 of connector X12 on the Control Board (A10)

eWith 120 VAC to the Control Board (A10) The Operation Board (A11) is energized

An alarm will sound for one second

All the LED’s and the display will energize one at a time.

“STARTING” will be displayed for 3 seconds

“Please wait” will be displayed

The international model number will be displayed

The time and date will be displayed and this will continue until the on/off switch is depressed.

3When the ON/OFF is depressed with the combi in the steam mode a The display will show the set temperature and set time.

4With the combi in the steam mode with time on the timer, the door closed and the start switch is depressed

Image 67
Contents Service & Parts Manual Table of Contents For the Installer Cleveland Statement of Policies General Information about Combis Installation Instructions Installation of the Combi General Instructions Page Cleveland Range, LLC Advanced Closed System offers the following advantages GAS Fired Boilerless Total Connected Load 265,500 BTU 239,000 BTU Propane Hot Air Control Panel Basic Operation Control Panel Detail View Function Indicators AT the END of the DAY or Shift Avoid scratching the oven chamber or engaging frame Page Semi-Automatic Cleaning of the Oven Chamber Page CONVOClean Automatic Cleaning System optional Page Descale Steam Generator General Safety for Descaling Page GAS Generator W Cleaning QTY Part N0 Description GAS INJ W Cleaning FAN, AIR Inlet BOX Assembly GAS OGB 20.20 Models Component Panel ASSEMBLY, GASALL Models ASSEMBLY, Control PANEL, with PictoItem QTY Part N0. Description ASSEMBLY, Outer BasePage ASSEMBLY, Water Hose SYSTEM, Condenser ALL 20.20 Models ASSEMBLY, Water ValveValve Assy WAY 120VAC OGS 20.20 Models ALL GAS Models Burner INSERT, HL, PRE-MOUNTEDBur C26 Bur C26 Burner INSERT, HL, PRE-MOUNTED, 6.10/6.20 ASSEMBLY, Burner INSERT, AIR, LP & NAT GASCom Bu Com Bu PUMP, Steam GENERATOR, GAS Models Door CompleteALL 6.20, 10.10 Models & 20.20 Models Sliding PLATE, CompleteDetail B Exterior Sheeting Cleveland Range OGB Sequence of Operations Page Page Page Page Page Page Cleveland RANGE, LLC Wiring Diagram A12 A10 A20 N20 U20 345678 N22 Ladder Diagram Page GAS Board Cleveland Range OGS Sequence of Operations Page Page Page Page Page OGS X13.6 U10.1 S3WIRING Diagram X28 4567 X1021 Sheet 6 HOT Lower Agas Valve Wiring Diagram Wattage