Alto-Shaam MN-29245 manual E21, E22, E23, E24, E25, E26, E27, E34, E35, E36, E40, E41

Page 31

 

 

I NST ALLATIO

N

 

 

 

 

 

 

 

 

 

 

ERR O R COD ES

 

 

 

 

 

 

 

 

 

 

 

 

 

Error

Dis play Show s

Whe n d oes t he error

 

Possible reason

Code

occur?

 

 

 

 

 

 

 

 

E20

HACCP Only - B11 Core

Single point core temperature

— Clean Probe Receptacle Pins with sand paper.

 

Temperature Probe Single

probe defect or disconnected

— B11 Single Point Core Temperature probe with quick

 

Point Fault

 

connect, defective.

 

Error E20 is not shown in display.

 

— B11 Single Point Core Temperature probe wires with

 

 

quick connect, disconnected.

 

Instead a probe sign with "?" is

 

 

 

— B11 Single Point Core Temperature probe receptacle,

 

shown as popup window. In case

 

 

 

defective.

 

the customer cooks in time mode

 

 

 

— B11 Single Point Core Temperature probe receptacle

 

during first step and during second

 

 

 

wires disconnected.

 

step switches to probe mode but has

 

 

 

 

 

 

no probe in place, the error E20 will

 

 

 

 

be shown in the error code list and

 

 

 

 

HACCP list.

 

 

 

 

 

 

 

E21

N6 Cavity Probe Fault

Cavity temperature probe defect

— N6 Oven Cavity Temperature probe defective.

 

 

or disconnected

— N6 Oven Cavity Temperature connection problem.

 

 

 

 

E22

B10 Core Temperature Probe

Multipoint core temperature probe

— B10 Multipoint Core Temperature probe defective.

 

Multipoint Fault

defect or disconnected

— B10 Multipoint Core Temperature probe connection

 

 

 

problem disconnected.

 

 

 

 

E23

B4 Boiler Probe Fault

Boiler temperature probe defect

— B4 Boiler temperature probe defective.

 

 

or disconnected

— B4 probe wires connection problem.

 

 

 

 

E24

B5 Bypass Probe Fault

Bypass steam temperature probe

— B5 Bypass steam temperature probe defective.

 

 

defect or disconnected

— B5 Bypass steam temperature connection problem.

 

 

 

 

E25

B3 Condensor Probe Fault

Condensor water temperature

— B3 Condensor temperature probe defective.

 

 

probe defect or disconnected

— B3 Condensor probe connection problem.

 

 

 

 

E26

N8 Boiler Safety Temperature

Steam generator heating element

— N8 Boiler temperature probe defective.

 

Probe Fault

protection probe defect or

— N8 probe connection problem.

 

 

disconnected

 

 

 

 

 

 

E27

Boiler Element Temperature

Excess steam generator safety

— Scale build up inside steam generator.

 

High

probe

— Defective water level probe.

 

 

 

— Water level probe connection failure.

 

 

 

— N8 boiler temperature probe defective.

 

 

 

— N8 probe connection problem.

 

 

 

— Steam element contactor(s) stuck closed.

 

 

 

 

E34

Steam Generator Drain Pump

Water level in steam generator

— Scale build up inside the steam generator drain pump.

 

Fault

does not drop during cleaning

— Generator drain pump is faulty

 

 

program

— Connection issue at drain pump.

 

 

 

— No output to pump from relay board.

 

 

 

 

E35

Vent not closed

Browning valve does not close

— Alignment issue between motor cam and vent motor

 

 

completely

safety switch (micro switch).

 

 

 

— Fault vent valve (motor).

 

 

 

— Fault vent valve safety switch (micro switch).

 

 

 

— Wiring or connection problem.

 

 

 

 

E36

Steam Temperature High

Oven cavity temperature is too

— Water supply is shut off.

 

 

high when operating in a steam

— Low water pressure.

 

 

mode or cleaning program

— Water injection pipe obstructed.

 

 

 

— Water flow valve plugged or defective.

 

 

 

— Dual solenoid valve Y-1 obstructed or defective.

 

 

 

— No output to solenoid valve form relay board.

 

 

 

 

E40

B3 Condensor Probe Short to

Condensor water temperature

— B3 condensor temperature probe defective.

 

Frame

probe short to ground

— Probe connection problem.

 

 

 

 

E41

B4 Boiler Probe Short to

Boiler protection temperature

— B4 boiler temperature probe defective.

 

Frame

probe short to ground

— Probe connection problem.

 

 

 

 

 

COMBITOUCH™ ES SERIES • ELECTRIC INSTALLATION MANUAL • 29 .

CONTINUED ON NEXT PAGE

Image 31
Contents FAX 262.251 .7067 Phone 262.251.3800Ventless Hood Option Auti on DAN GER Site Inst Alla Tion SI TE INS Tallatio N20 508mm 18 457mm2mm NST Allatio FI-29 Wire 610 714Probe, Sous Vide PR-34 Combither m Clean ing Li quid CE-24 FI-28WE Ight 610ESDIM ENS Ions H x W x D EL EctricaEnts Weight Capa CIT Y610ESi INS TA LL AT IONS iN/ sk 610ESiNINS TA LL AT ION Requirem Ents Elec TR IC AL1010ES 101 0 E S 101 0 E S i/sk 1010ESiS iN/sk 1010ESiNWeig HT Capa CIT Y 714ES WE Ight Capa City 714ESiElect Rical 14 E S S i/sk1018ES 1018ESi Weight CAP ACI TY1018 ES 101 8 E S i/sk 1220ES INS TA LL AT ION Requirem Ents Oven must be installed level122 0 E S 122 0 E S i/sk 1220ESi2020ES 202 0 E S 20 20 E S i/sk 2020ESiElectr I CAL Conne CT IO N AngerElectr Ical CO Nnect ION Mobile EQ Uipment Estr Aint INS TA LlationUSE a DR Inking Qualit OLD WAT ER Supply only WAT ER Quality RE QUI R Ement30 to 90 psi WAT ER Connect IO NSCan manifold off of one 3/4 line To 6.2 bar WAT ER DR Aina GE WAT ER Valv EPla ce ALL Functions are Displayed YES CO Mbit Ouch CHE CKL ISTAre ALL Clearance CLE Aranc ES Electrical Supply Line SizeERR O R COD ES E24 E21E22 E23E51 E43E44 E45Press the Start Icon to Acknowle DGE the ER ROR ERR O R CODType of Erro r Indicatio n Release o f E rror Motor Control Error CodesCondens ATE D RA Ventl ESS HO OD OP T IONOP ERA Tion ORI GI N AL E Quip Ment Limi TED Warrant Y RA NSP O RTA TIO N D Amage Laims