Alto-Shaam MN-29245 manual E43, E44, E45, E51, E53, E55, E57, E93, E94, E96, E97

Page 32

 

 

 

I NST ALLATIO

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ERR O R COD ES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error

Displ ay Show s

Whe n d oes t he e rror

 

Possible reason

 

Code

occur?

 

 

 

 

 

 

 

 

 

 

 

 

 

E42

B5 Bypass Probe Short to

Bypass steam temperature probe

— B5 bypass steam temperature probe defective

 

 

Frame

short to ground

— Probe connection problem.

 

 

 

 

 

 

 

E43

N6 Cavity Probe Short to

Cavity temperature probe short to

— N6 oven cavity temperature probe defective

 

 

Frame

ground

— Probe connection problem.

 

 

 

 

 

 

 

E44

N8 Boiler Safety Temperature

Boiler heating element protection

— N8 boiler temperature probe defective.

 

 

Probe Short to Frame

probe short to ground

— Probe connection problem.

 

 

 

 

 

 

 

E45

B10 Core Temperature Probe

Multipoint core temperature probe

— B10 multipoint core temperature probe defective.

 

 

Short to Frame

short to ground

— Probe connection problem.

 

 

 

 

 

 

 

E51

No Water In Boiler

No water inside steam generator

— Water supply is shut off.

 

 

 

 

— Low water pressure.

 

 

 

 

— Generator drain cap missing or loose.

 

 

 

 

— Generator drain pump is not sealing.

 

 

 

 

— Generator drain pump elbow leaking.

 

 

 

 

— Faulty or scaled water level probe.

 

 

 

 

— Faulty or plugged dual solenoid valve assembly.

 

 

 

 

— Wiring or connection issue.

 

 

 

 

— No output to dual solenoid from relay board.

 

 

 

 

 

 

 

E53

Fan Motor High Temperature

Fan motor too hot

— Check LED flashes on the motor control

 

 

 

 

(See Motor Control Error Code list).

 

 

 

 

— Motor seized or defective sensor.

 

 

 

 

— Hall sensor does not detect motor rotation.

 

 

 

 

 

 

 

E55

Vent not open

Browning valve does not open

— Alignment issue between motor cam and vent motor

 

 

 

 

safety switch (micro switch).

 

 

 

 

— Fault vent valve (motor).

 

 

 

 

— Probe connection problem.

 

 

 

 

— Fault vent valve safety switch (micro switch).

 

 

 

 

— Wiring or connection problem.

 

 

 

 

 

 

 

E57

No rinse water

During rinse no water flow is

— Water supply is shut off.

 

 

 

detected trough solenoid valve

— Low water pressure.

 

 

 

 

— Check wiring to all components mention below.

 

 

 

 

— Flow switch dirty or defect.

 

 

 

 

— Double water solenoid valve defective (Y3.)

 

 

 

 

— Relay board, high voltage, defective.

 

 

 

 

 

 

 

E93

Communication Error, FROM

Communication error between

— Check ribbon cable connections mention below.

 

 

Display Board

display board and low voltage

— Ribbon cable defective.

 

 

 

relay board

— Relay board, low voltage, connector defective.

 

 

 

 

— Display board connector defective.

 

 

 

 

 

 

 

E94

Communication Error, TO

Communication error between

— Check ribbon cable connections mention below.

 

 

Display Board

display board and low voltage

— Ribbon cable defective.

 

 

 

relay board

— Relay board, low voltage, connector defective.

 

 

 

 

— Display board connector defective.

 

 

 

 

 

 

 

E96

Communication Error, TO

Communication error between

— Check ribbon cable connections mention below.

 

 

RBL

display board and low voltage

— Ribbon cable defective.

 

 

 

relay board

— Relay board, low voltage, connector defective.

 

 

 

 

— Display board connector defective.

 

 

 

 

 

 

 

E97

Communication Error, FROM

Communication error between

— Check ribbon cable connections mention below.

 

 

RBL

relay board, high voltage and

— Ribbon cable defective

 

 

 

relay board, low voltage

— Relay board, low voltage, connector defective.

 

 

 

 

— Relay board, high voltage, connector defective.

 

 

 

 

 

 

 

 

Motor Control Error

Internal motor control

See Motor Control Error chart on following page.

 

 

 

 

 

 

 

COMBITOUCH™ ES SERIES • ELECTRIC INSTALLATION MANUAL • 30 .

Image 32
Contents Phone 262.251.3800 FAX 262.251 .7067Ventless Hood Option Auti on DAN GER SI TE INS Tallatio N Site Inst Alla Tion2mm 18 457mm20 508mm NST Allatio Wire 610 714 Probe, Sous Vide PR-34 Combither m Clean ing Li quid CE-24FI-28 FI-29610ES DIM ENS Ions H x W x DEL Ectrica WE IghtWeight Capa CIT Y 610ESiINS TA LL AT ION Ents610ESiN INS TA LL AT ION Requirem EntsElec TR IC AL S iN/ sk1010ES 1010ESi 101 0 E S 101 0 E S i/skWeig HT Capa CIT Y 1010ESiNS iN/sk 714ES 714ESi Elect Rical14 E S S i/sk WE Ight Capa City1018ES 1018 ES 101 8 E S i/sk Weight CAP ACI TY1018ESi INS TA LL AT ION Requirem Ents Oven must be installed level 1220ES1220ESi 122 0 E S 122 0 E S i/sk2020ES 2020ESi 202 0 E S 20 20 E S i/skAnger Electr I CAL Conne CT IO NElectr Ical CO Nnect ION INS TA Llation Mobile EQ Uipment Estr AintWAT ER Quality RE QUI R Ement USE a DR Inking Qualit OLD WAT ER Supply onlyCan manifold off of one 3/4 line To 6.2 bar WAT ER Connect IO NS30 to 90 psi Pla ce WAT ER Valv EWAT ER DR Aina GE CO Mbit Ouch CHE CKL IST Are ALL Clearance CLE Aranc ESElectrical Supply Line Size ALL Functions are Displayed YESERR O R COD ES E21 E22E23 E24E43 E44E45 E51ERR O R COD Press the Start Icon to Acknowle DGE the ER RORMotor Control Error Codes Type of Erro r Indicatio n Release o f E rrorVentl ESS HO OD OP T ION Condens ATE D RAOP ERA Tion ORI GI N AL E Quip Ment Limi TED Warrant Y RA NSP O RTA TIO N D Amage Laims