Alto-Shaam MN-29245 manual Err O R Cod, Press the Start Icon to Acknowle DGE the ER ROR

Page 33

 

 

 

I NST ALLATIO

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ERR O R COD

ES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When the ove n ma lfunc tio ns, an error cod e will ap pear in the

display .

 

 

 

 

PRESS THE START ICON TO ACKNOWLE DGE THE ER ROR.

 

 

 

 

The i cons th at begin

to f las h represent o perational

mod es t hat ar e still usable.

 

 

 

When the ove n fau lt is correc ted, the Co mbi the rm will r eturn to nor mal Oper ation.

 

 

 

Error

 

 

 

Model

 

 

Mode

 

 

 

Dis play Shows

 

 

 

 

 

 

 

 

 

 

ESG

 

 

 

 

 

 

Code

ES

Steam

Comb inat ion

Conv ecti on

Rether m

 

 

 

 

 

 

 

 

 

ESI

 

 

 

 

 

 

E01

 

Low Water Boiler

 

Yes

No

No

No

To 365°F

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E02

 

Control Temp High

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E03

 

Fan Motor Error

 

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E11

 

Convection Temperature High

Yes

Yes

BOILER

UNITS

No

No

No

 

 

 

 

 

 

 

 

 

 

ONL Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E13

 

Boiler Temperature High

Yes

No

No

No

Yes

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E15

 

Condensor Temperature High

Yes

Yes

No

No

To 356°F

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E20

 

B11 Core Temperature Probe Single

Yes

Yes

No

No

No

No

 

 

 

 

 

 

Point Fault - HACCP only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E21

 

N6 Cavity Probe Fault

Yes

Yes

BOILER

UNITS

No

No

No

 

 

 

 

 

 

 

 

 

 

ONL Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E22

 

B10 Core Temp Probe Fault

Yes

Yes

BY TIME ONL Y

BY TIM E ON LY

BY TIME ONL Y

BY TIME ONLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E23

 

B4 Boiler Probe Fault

Yes

No

No

No

No

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E24

 

B5 Bypass Probe Fault

Yes

Yes

No

No

Yes

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E25

 

B3 Condensor Probe Fault

Yes

Yes

Yes

No

To 356°F

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E26

 

N8 Boiler Safety Temperature Probe Fault

Yes

No

No

No

No

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E27

 

Boiler Element Temperature High

Yes

No

No

No

Yes

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E34

 

Steam Generator Drain Pump Fault

Yes

No

No

No

No

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E35

 

Vent Not Closed

 

Yes

Yes

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

(NO BR OWNIN G)

(NO BR OW NING )

(NO BR OW NING )

(NO BROWNING)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E36

 

Steam Temperature High

Yes

No

No

No

Yes

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E40

 

B3 Condensor Probe Short to Frame

Yes

Yes

No

No

To 356°F

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E41

 

B4 Boiler Probe Short to Frame

Yes

No

No

No

Yes

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E42

 

B5 Bypass Probe Short to Frame

Yes

Yes

No

No

Yes

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E43

 

N6 Cavity Probe Short to Frame

Yes

Yes

BOILER

UNITS

No

No

No

 

 

 

 

 

 

 

 

 

 

ON LY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E44

 

N8 Boiler Safety Temperature Probe Short

Yes

No

No

No

Yes

No

 

 

 

 

 

 

to Frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E45

 

B10 Core Temperature Probe Short to Frame

Yes

Yes

BY TIME ONL Y

BY TIM E ON LY

BY TIME ONL Y

BY TIME ONLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E51

 

No Water in Boiler

Yes

No

No

No

Yes

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E53

 

Fan Motor High Temperature

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E55

 

Vent Not Open

 

Yes

Yes

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

(NO BR OWNIN G)

(NO BR OW NING )

(NO BR OW NING )

(NO BROWNING)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E57

 

No Rinse Water

 

Yes

Yes

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E93

 

Communication Error FROM Display Board

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E94

 

Communication Error, TO Display Board

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E96

 

Communication Error, TO RBL

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E97

 

Communication Error, FROM RBL

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMBITOUCH™ ES SERIES • ELECTRIC INSTALLATION MANUAL • 31 .

Image 33
Contents FAX 262.251 .7067 Phone 262.251.3800Ventless Hood Option Auti on DAN GER Site Inst Alla Tion SI TE INS Tallatio N18 457mm 20 508mm2mm NST Allatio Probe, Sous Vide PR-34 Combither m Clean ing Li quid CE-24 Wire 610 714FI-28 FI-29DIM ENS Ions H x W x D 610ESEL Ectrica WE Ight610ESi Weight Capa CIT YINS TA LL AT ION EntsINS TA LL AT ION Requirem Ents 610ESiNElec TR IC AL S iN/ sk1010ES 101 0 E S 101 0 E S i/sk 1010ESi1010ESiN S iN/skWeig HT Capa CIT Y 714ES Elect Rical 714ESi14 E S S i/sk WE Ight Capa City1018ES Weight CAP ACI TY 1018ESi1018 ES 101 8 E S i/sk 1220ES INS TA LL AT ION Requirem Ents Oven must be installed level122 0 E S 122 0 E S i/sk 1220ESi2020ES 202 0 E S 20 20 E S i/sk 2020ESiElectr I CAL Conne CT IO N AngerElectr Ical CO Nnect ION Mobile EQ Uipment Estr Aint INS TA LlationUSE a DR Inking Qualit OLD WAT ER Supply only WAT ER Quality RE QUI R EmentWAT ER Connect IO NS 30 to 90 psiCan manifold off of one 3/4 line To 6.2 bar WAT ER Valv E WAT ER DR Aina GEPla ce Are ALL Clearance CLE Aranc ES CO Mbit Ouch CHE CKL ISTElectrical Supply Line Size ALL Functions are Displayed YESERR O R COD ES E22 E21E23 E24E44 E43E45 E51Press the Start Icon to Acknowle DGE the ER ROR ERR O R CODType of Erro r Indicatio n Release o f E rror Motor Control Error CodesCondens ATE D RA Ventl ESS HO OD OP T IONOP ERA Tion ORI GI N AL E Quip Ment Limi TED Warrant Y RA NSP O RTA TIO N D Amage Laims