| I NST ALLATIO | N | ||
|
|
|
| |
|
|
|
| |
ERR O R COD ES |
|
| ||
|
|
|
| |
Motor Control Error Codes |
|
| ||
|
|
|
| |
Type of Erro r | Indicatio n |
| Release o f E rror | |
|
|
| ||
Undervoltage | LED flashing sequence, with 1 flash per period. | Voltage of intermediate circuit is less than 250V | ||
|
|
| ||
Overvoltage | LED flashing sequence, with 2 flashes per period. | Voltage of intermediate circuit exceeds 445V | ||
|
|
|
| |
Excess | LED flashing sequence, with 3 flashes per period. | Temperature sensor in the power unit is more than than 93°C | ||
Temperature | ||||
|
|
| ||
|
|
| ||
Overcurrent | LED flashing sequence, with 4 flashes per period. | Blocked motor, detected by current peak monitoring from | ||
|
| 900 rpm rotating field | ||
|
|
| ||
Overcurrent | LED flashing sequence, with 5 flashes per period. | Intermediate circuit current exceeds 4.0A | ||
|
|
| ||
LED flashing sequence, with 6 flashes per period. | Release of interrupt at intermediate circuit current larger | |||
|
| than 53A |
| |
|
|
| ||
Power on | LED flashing sequence, with 7 flashes per period. | Effective mains voltage does not correspond to jumper setting | ||
|
| 115V/230V |
| |
|
|
| ||
Watchdog | LED flashing sequence, with 8 flashes per period. | Watchdog of the microcontroller released, program crash | ||
|
|
|
|
COMBITOUCH™ ES SERIES • ELECTRIC INSTALLATION MANUAL • 32 .