Figure 28: Display Calibration Menu Screen
3.Once in “Scale Calibration”, enter in the scale calibration weight value stamped on the side of the weight.
4.The controller will prompt you to remove the weight hopper and press OK.
5.After touching OK, the controller will display “PLEASE WAIT...”
6.Next, the controller will ask you to hang the calibration weight on the right loadcell bracket (loadcell A) and press OK.
7.The controller will ask you to hang the calibration weight on the left loadcell bracket (loadcell B) and press OK.
8.Finally, the controller will ask you to replace the weigh hopper in the blender and press OK to complete the calibration.
9.The controller will verify that the calibration was done correctly by showing “Calibration Successful.”
10.Press “Done” until you have reached the Recipe screen.
Figure 29: Display Calibration Screen
Current Loadcell
Bits
Follow
Instructions
Enter in the Calibration Weight
Press here to perform the calibration
Go Back to the Calibration Directory
Verifying Calibration (Recommended on a periodic basis to ensure accuracy)
1.From the “Recipe” Page, touch the Manufacturer’s icon and enter “5413”, then press the “Enter” key.
2.Touch “Calibration” and then “Direct Scale Readout”.
3.Remove the weigh hopper.
4.Locate the weight display for each of the two load cells directly below “Current Bits.” Write down the displayed value.
Chapter 3: 2BInstallation | 40 of 101 |