Unified Brands HY-6G(CE) Steam Port Gasket, Cavity Steam Hose Assemblies P/N 099953 Top

Page 30

1.Turn off power to the steamer.

2.Unplug the two wires from the thermostat.

3.Using a wrench, remove the thermostat.

4.To install a new thermostat, use a small amount of heat sink compound (1 drop), applied to bottom of thermostat. Seat the thermostat on the steam port and connect.

5.Plug the thermostat into the wiring harness.

10.22 Steam Port

Gasket

P/N 096736

P/N 099250

1.Shut off power to the steamer.

2.Remove the 1-1/8 inch steam hose by loosening the clamp around the hose and sliding it away from the steam port. Turn and pull to loosen hose and remove from steam port.

3.With a wrench, remove the screws holding the thermostat to the steam port.

4.Cut and fold up aluminum foil insulation blanket to expose the two nuts which hold the steam port to the cavity wall threaded studs.

5.With a wrench, remove the two nuts.

6.Remove the steam port.

To Install:

7.Put a small bead of silicone sealant in and around the groove in the steam port to seal any possible leaks, or use gasket P/N 099250.

8.Install steam port on threaded studs. Secure with two nuts.

9.Fold down aluminum foil insulation blanket to original blanket position and repair cuts with aluminum foil duct tape.

10.Reinstall thermostat as described in 10.20 above.

11.Reinstall steam hose to steam port and install the clamp.

10.23Cavity Steam Hose Assemblies P/N 099953 (Top)

P/N 088880 (Bottom)

There are two hoses which connect the steam generators with their respective cavities. One for the top

cavity and one for the bottom cavity. If both hoses are to be replaced, replace them one at a time.

1.Shut off power to the steamer.

2.Remove cavity side and lower side panels of table.

3.In the upper portion of the steamer, remove hose. Turn and pull the hose to remove it from the hose nipple.

4.In the lower section of the steamer, remove the hose clamp from where the hose is connected to the steam generator. Turn and pull the hose to remove it from the hose nipple.

5.The hose may be removed. Be careful that the hose clamps do not fall off and get lost.

IMPORTANT: Make sure that the correct part (and part number) are being used. The two hoses in the steamer are of different lengths. (See Page 21 for Part Numbers.)

To Install:

6.Slide the two hose clamps onto the hose and position the hose adjacent to the steam port and steam generator.

7.Slide the hose onto the hose nipple on the steam port and at the other end, onto the steam generator nipple. Make sure the hose is on all the way so that the end of the hose is against the face of the nipples.

8.Install the hose clamps 3 mm (1/8") from the end of the hose.

10.24Door Removal/Installation/Alignment P/N 094150

1.To remove the door, turn off the steamer power and allow the steamer to cool. Then, remove door by supporting the weight of the door and remove hinge pin.

2.Place the door on a flat, clean table or similar support, with gasket facing up. Be careful not to scratch door surface.

3.Inspect door gasket for signs of cuts or other defects which may impair its function. Replace if necessary.

To Install:

4.To install the door, apply NEVER-SEEZ lubricant to hinge pin. Align door with hinge and insert hinge pin.

30 OM/SM-HY-6G(CE)

Image 30
Contents HY-6GCE Hypersteam Atmospheric Convection Important Read First Important Table of Contents ReferencesEquipment Description Inspection and UnpackingWater Conditioning Bpst Connection on the right rear side of the steamerElectrical Supply Connection Installation, Start-Up and ConversionGeneral Gas Supply ConnectionG20 Natural Gas G31 Propane Gas MBar Inch W.C 26.25 10.5 Natural Gas Propane GasMBar In. W.C 10.5 in. W.C Natural Gas Propane Gas Injector No.Drain Connection Initial Start-UpAutomatic Operation of Pilot Operation Gas Lockout Indicator and Reset ControlOperating Procedure ControlsOM/SM-HY-6GCE Suggested Tools CleaningProcedure Outside of Steamer 12 OM/SM-HY-6GCEIf the Service light stays on Steam Generator and Cooking ChamberMaintenance Troubleshooting14 OM/SM-HY-6GCE Parts List External Cabinet and Sheet MetalKey Description Cavity Control Section 16 OM/SM-HY-6GCESteamer Base Section Front Steamer Base Rear 18 OM/SM-HY-6GCESteamer Plumbing Steamer Motor and Controls 20 OM/SM-HY-6GCESteamer Generator Individual Parts Key Description NewSteamer Individual Parts 22 OM/SM-HY-6GCETop Right Side Panel Louvered Removal P/N Service ProceduresAdjustable Legs P/N Left Side Removal P/NWater Inlet Valve Coil To TestWater Inlet Valve Three Way P/N Drain Box Spray Nozzle P/NSteam Generator To InstallMain Gas Valve and Gas Pressure Adjustment P/N Steam Generator Probes High and Low Water P/NGas Solenoid Valve P/N To ReinstallTo Assemble Igniter Module P/NInstallation Pilot Switch SW3 Removal P/NTo replace the switch Pilot Flame Current CheckTo Reassemble Timer Assembly Timer Fastener NutSteam Generator Gas Jet Manifolds P/N 123704 28 OM/SM-HY-6GCETo Install New Capacitor Fan Motor Assembly Motor Insulation Motor Shaft SealTo Install a New Motor 10.18 FanCavity Steam Hose Assemblies P/N 099953 Top Door Removal/Installation/Alignment P/NSteam Port Gasket 30 OM/SM-HY-6GCEDoor Switch P/N Door Reversing ProceduresTo Align Door Spring P/N Door Handle, Magnet and Block AssemblyDoor Gasket P/N 32 OM/SM-HY-6GCEDoor Locking Pin P/N Lock Nut P/N Electrical Schematic 34 OM/SM-HY-6GCEService Log Limited Warranty To Commercial Purchasers 36 OM/SM-HY-6GCEPart Number 128805, REV. C 4/06

HY-6G(CE) specifications

Unified Brands HY-6G(CE) is a pioneering cooking solution in the commercial kitchen landscape, known for its exceptional performance, versatility, and cutting-edge technologies. Designed to meet the rigorous demands of foodservice establishments, the HY-6G(CE) excels at efficiently preparing a wide range of dishes while ensuring consistent quality and safety.

One of the standout features of the HY-6G(CE) is its powerful heating capability. Equipped with advanced infrared heating technology, this unit delivers rapid and uniform heat distribution, making it ideal for both quick service and high-volume operations. The adjustable temperature controls allow chefs to fine-tune the cooking process, ensuring that every dish meets their exacting standards.

Another innovative aspect of the HY-6G(CE) is its energy efficiency. The incorporation of smart energy management systems ensures optimal power usage, reducing operational costs without sacrificing performance. The unit’s environmentally friendly design also aligns with sustainability initiatives, making it a responsible choice for modern kitchens.

The HY-6G(CE) boasts a user-friendly interface that facilitates ease of operation. Its digital display provides real-time feedback on cooking parameters, while programmable settings enable chefs to recall precise cooking profiles for various menu items. This feature not only streamlines kitchen workflow but also enhances productivity, allowing staff to focus on delivering exceptional customer service.

Durability is another hallmark of the HY-6G(CE). Constructed from high-quality stainless steel, it withstands the rigors of daily use in busy kitchens while resisting corrosion and wear. Its compact design allows for easy integration into existing kitchen layouts, making it an excellent option for both new builds and remodels.

Safety is paramount in any culinary environment, and the HY-6G(CE) addresses this with multiple safety features. These include automatic shut-off mechanisms and thermal protection systems that safeguard against overheating, ensuring secure operation even in the most demanding settings.

In summary, Unified Brands HY-6G(CE) stands out in the commercial cooking equipment market due to its blend of power, efficiency, and safety. With features that cater to the diverse needs of any foodservice establishment, it is an invaluable tool for chefs looking to elevate their culinary offerings while maintaining operational excellence. Whether in a bustling restaurant or a catering operation, the HY-6G(CE) is designed to deliver reliable and outstanding results.