Whirlpool UXT5230AYW installation instructions Make Electrical Connection, Complete Installation

Page 11

Make Electrical Connection

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Disconnect power.

 

 

G

C

D

E

 

 

A

B

F

A. White wires

E. Home power supply cable or

B. Black wires

power cord accessory kit

C. UL listed wire connector

F. UL listed or CSA approved

D. Green (or bare) ground wire

½" strain relief

G. Green ground screw

 

2.Use UL listed wire connectors and connect white wires (A) together.

3.Use UL listed wire connectors and connect black wires (B) together.

WARNING

Fire Hazard

Electrically ground the blower.

Use copper wire.

Connect ground wire to green ground screw in terminal box.

Failure to do so can result in death, fire, or electrical shock.

4.Connect green (or bare) ground wire from power supply to green ground screw in terminal box and securely tighten.

5.Install terminal box cover.

6.Reconnect power.

Complete Installation

1.Replace the 2 bottom panels.

a.Place the back of the panel into the rear channel and push the panel toward the back of the range hood until the tabs on the front of the panel clear the front mounting flange.

b.Push the front of the panel up into the front mounting flange until the panel tabs align with the slots in the front mounting flange. Release the panel so the tabs lock the panel in place.

2.Replace grease filter. See the “Range Hood Care” section.

3.Check the operation of the range hood fan and light. See “Range Hood Use” section.

If range hood does not operate, check to see whether a circuit breaker has tripped or a household fuse has blown. Disconnect power and check wiring connections.

NOTE: To get the most efficient use from your new range hood, read the “Range Hood Use” section.

11

Image 11
Contents Hotte D’ASPIRATION DE Table of Contents Range Hood SafetyImportant Safety Instructions Location Requirements Installation RequirementsTools and Parts Venting Methods Installation Clearances Cold Weather InstallationsVenting Requirements Makeup AirExample vent system Electrical RequirementsCalculating Vent System Length Cm Round Vent SystemDetermine Wiring Hole Location Installation InstructionsTo wire through top To wire through wallTo make a 3½ x 10½ 8.9 cm x 26.7 cm rectangle in the wall Install Vent SystemWall Venting Style 3 Cut Openings for 7 17.8 cm Round VentInstall Range Hood Power Supply Cable Installation Make Electrical Connection Complete InstallationRange Hood Controls CleaningRange Hood USE Range Hood CareReplacing a Halogen Lamp To Replace the FilterSE119A Wiring DiagramCanada Assistance or ServiceAccessories U.S.AThis limited warranty does not cover Whirlpool Corporation Major Appliance WarrantyVotre sécurité et celle des autres est très importante Sécurité DE LA Hotte DE CuisinièreImportantes Instructions DE Sécurité Outils et pièces Exigences DinstallationExigences demplacement Air d’appoint Installations dans les régions au climat froidExigences concernant l’évacuation Distances de dégagement à respecterSystème dévacuation avec conduits ronds de 7 17,8 cm Exemple de circuit d’évacuationSystème de décharge de 3¹⁄₄ x 10 8,3 cm x 25,4 cm Calcul de la longueur du circuit d’évacuationSpécifications électriques Instructions D’INSTALLATIONPréparation de lemplacement Déterminer l’emplacement du trou de passage du câbleÉvacuation par le mur Câblage à travers le sommet du placardPassage du câble à travers le mur Installation du conduit d’évacuation Installation de la hotteDécoupe en trou de serrure Installation sans décharge à l’extérieur recyclage Installation du cordon dalimentationRaccordement électrique Achever l’installationNettoyage Commandes de la hotte de cuisinièreEntretien DE LA Hotte Remplacement d’une lampe à halogène Remplacement du filtreSchéma DE Câblage SE119AAu Canada Assistance OU ServiceAccessoires Garantie DES Gros Appareils Ménagers Whirlpool CorporationW10400323E