Whirlpool UXT5230AYW installation instructions Install Range Hood

Page 9

Install Range Hood

1.Remove metal grease filter. See the “Range Hood Care” section.

2.Remove the 2 bottom panels.

A

A. Bottom panels

a.Push the panel toward the back of the range hood until the front tabs of the panel clear the front mounting flange.

b.Pull down on the front of the panel and pull the panel away from the rear channel. Set panels aside.

NOTE: Your model will have a 3¼" x 10" (8.3 x 25.4 cm) rectangular vent damper on the inside your range hood.

3.Remove the 3¼" x 10" (8.3 x 25.4 cm) rectangular vent damper taped on the inside your range hood.

4.Lift the range hood up under cabinet and determine final location by centering beneath cabinet. Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood. Set range hood aside on a covered surface.

A

A. Keyhole slot

5.Use ¹⁄₈" (3 mm) drill bit and drill 4 pilot holes as shown.

A

A. Drill pilot hole

6.Install the 4 - 4.5 mm x 13 mm mounting screws in pilot holes. Leave about ¹⁄₄" (6.4 cm) space between screw heads and cabinet to slide range hood into place.

¹⁄₄"

(6.4 mm)

7.Remove vent knockouts depending on your installation requirements.

A

B

C

A. Round vent knockout

B. Top rectangular vent knockout

C. Rear rectangular vent knockout

Round vent system installations - Remove top rectangular and round vent knockouts.

Rectangular vent system installations - For roof installations, remove the top rectangular vent knockout. For wall installations, remove the rear rectangular vent knockout.

Non-vent (recirculating) installations - Do not remove any knockouts.

8.Install 7" (17.8 cm) round vent mounting plate or 3¼" x 10" (8.3 x 25.4 cm) rectangular vent damper, depending on your vent system installation. Attach to range hood with the 3.5 x 5 mm screws provided and remove tape from damper flap.

NOTE: The 7" (17.8 cm) round vent mounting plate is not supplied. An optional 7" (17.8 cm) round damper is also available as an accessory. For information on ordering, see the “Accessories” section.

A

B

C

D

E

A. 7" (17.8 cm) Round damper (see “Accessories” section) B. 3.5 x 5 mm screws

C. 7" (17.8 cm) round vent mounting plate (see “Accessories” section)

D. Round vent knockout

E. Rectangular vent knockout

9

Image 9
Contents Hotte D’ASPIRATION DE Table of Contents Range Hood SafetyImportant Safety Instructions Installation Requirements Tools and PartsLocation Requirements Venting Requirements Installation Clearances Cold Weather InstallationsMakeup Air Venting MethodsCalculating Vent System Length Electrical RequirementsCm Round Vent System Example vent systemTo wire through top Installation InstructionsTo wire through wall Determine Wiring Hole LocationWall Venting Install Vent SystemStyle 3 Cut Openings for 7 17.8 cm Round Vent To make a 3½ x 10½ 8.9 cm x 26.7 cm rectangle in the wallInstall Range Hood Power Supply Cable Installation Make Electrical Connection Complete InstallationRange Hood USE CleaningRange Hood Care Range Hood ControlsReplacing a Halogen Lamp To Replace the FilterSE119A Wiring DiagramAccessories Assistance or ServiceU.S.A CanadaThis limited warranty does not cover Whirlpool Corporation Major Appliance WarrantyVotre sécurité et celle des autres est très importante Sécurité DE LA Hotte DE CuisinièreImportantes Instructions DE Sécurité Exigences Dinstallation Exigences demplacementOutils et pièces Exigences concernant l’évacuation Installations dans les régions au climat froidDistances de dégagement à respecter Air d’appointSystème de décharge de 3¹⁄₄ x 10 8,3 cm x 25,4 cm Exemple de circuit d’évacuationCalcul de la longueur du circuit d’évacuation Système dévacuation avec conduits ronds de 7 17,8 cmPréparation de lemplacement Instructions D’INSTALLATIONDéterminer l’emplacement du trou de passage du câble Spécifications électriquesCâblage à travers le sommet du placard Passage du câble à travers le murÉvacuation par le mur Installation du conduit d’évacuation Installation de la hotteDécoupe en trou de serrure Installation sans décharge à l’extérieur recyclage Installation du cordon dalimentationRaccordement électrique Achever l’installationCommandes de la hotte de cuisinière Entretien DE LA HotteNettoyage Remplacement d’une lampe à halogène Remplacement du filtreSchéma DE Câblage SE119AAccessoires Assistance OU ServiceGarantie DES Gros Appareils Ménagers Whirlpool Corporation Au CanadaW10400323E