Whirlpool UXT5230AYW Installation Requirements, Tools and Parts, Location Requirements

Page 4

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

Drill

1¹⁄₄" (3.0 cm) drill bit

¹⁄₈" (3.0 mm) drill bit for pilot holes

Pencil

Wire stripper or utility knife

Tape measure or ruler

Caulking gun and weatherproof caulking compound

Flat-blade screwdriver

Phillips screwdriver

Saber or keyhole saw

Metal snips

Compass or 8" (20.3 cm) circle template

Parts supplied

Remove parts from package. Check that all parts are included.

2 - 3.5 x 5 mm screws

3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular damper

T-10 Torx®† adapter

4 - 4.5 x 13 mm mounting screws

Parts needed

Wall or roof cap with damper to match vent system

3 - UL listed wire connectors

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on the left wall.

Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance. Consult the cooktop/range manufacturer installation instructions before making any cutouts.

Grounded electrical outlet is required. See “Electrical Requirements” section.

All openings in ceiling and wall where range hood will be installed must be sealed.

These range hoods are factory set for vented installations. Models that are capable of being installed as non-vented (recirculating) require charcoal filters. See the “Accessories” section to order charcoal filter kit.

For Mobile Home Installations

The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.

Product Dimensions

Vent clamps/duct tape as required

For 7" (17.8 cm) round vented installations:

7"

(17.8 cm) round metal vent system

7"

(17.8 cm) round damper. For information on ordering, see

 

the “Accessories” section.

⁷⁄₈" (2.2 cm)

6⁹⁄₁₆" (16.7 cm)

1" (2.5 cm)

7" (17.8 cm) round vent mounting plate. For information on

ordering, see the “Accessories” section.

For 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vented installations:

3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular metal vent system

For non-vented (recirculation) installations:

Charcoal filter kit. For information on ordering, see the “Accessories” section.

For cabinets with recessed bottoms:

Two 2" (5.1 cm) wide filler strips. Length and thickness determined by recess dimensions.

Four flat head wood screws or machine screws with washers and nuts (to attach filler strips).

4¹⁵⁄₁₆"

⁷⁄"

 

(12.5 cm)

(2.2 cm)

9"

 

 

 

 

(22.9 cm)

 

29¹⁵⁄₁₆" (76.0 cm) or

1¹⁄₂"

 

35¹⁵⁄₁₆" (91.0 cm)

(3.8 cm) 18⁵⁄₈"

 

 

(47.3 cm)

†®TORX is a registered trademark of Saturn Fasteners, Inc.

4

Image 4
Contents Hotte D’ASPIRATION DE Range Hood Safety Table of ContentsImportant Safety Instructions Tools and Parts Installation RequirementsLocation Requirements Installation Clearances Cold Weather Installations Venting RequirementsMakeup Air Venting MethodsElectrical Requirements Calculating Vent System LengthCm Round Vent System Example vent systemInstallation Instructions To wire through topTo wire through wall Determine Wiring Hole LocationInstall Vent System Wall VentingStyle 3 Cut Openings for 7 17.8 cm Round Vent To make a 3½ x 10½ 8.9 cm x 26.7 cm rectangle in the wallInstall Range Hood Power Supply Cable Installation Complete Installation Make Electrical ConnectionCleaning Range Hood USERange Hood Care Range Hood ControlsTo Replace the Filter Replacing a Halogen LampWiring Diagram SE119AAssistance or Service AccessoriesU.S.A CanadaWhirlpool Corporation Major Appliance Warranty This limited warranty does not coverSécurité DE LA Hotte DE Cuisinière Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Exigences demplacement Exigences DinstallationOutils et pièces Installations dans les régions au climat froid Exigences concernant l’évacuationDistances de dégagement à respecter Air d’appointExemple de circuit d’évacuation Système de décharge de 3¹⁄₄ x 10 8,3 cm x 25,4 cmCalcul de la longueur du circuit d’évacuation Système dévacuation avec conduits ronds de 7 17,8 cmInstructions D’INSTALLATION Préparation de lemplacementDéterminer l’emplacement du trou de passage du câble Spécifications électriquesPassage du câble à travers le mur Câblage à travers le sommet du placardÉvacuation par le mur Installation de la hotte Installation du conduit d’évacuationDécoupe en trou de serrure Installation du cordon dalimentation Installation sans décharge à l’extérieur recyclageAchever l’installation Raccordement électriqueEntretien DE LA Hotte Commandes de la hotte de cuisinièreNettoyage Remplacement du filtre Remplacement d’une lampe à halogèneSE119A Schéma DE CâblageAssistance OU Service AccessoiresGarantie DES Gros Appareils Ménagers Whirlpool Corporation Au CanadaW10400323E