Cres Cor CCBC-4-35, CCBC-12-75, CCBC12-UA-100 service manual Service & Troubleshooting

Page 21

[ Section 5- Troubleshooting ]

[ Page 19 ]

SERVICE & TROUBLESHOOTING

Setting or Resetting Time and Date

 

SET UP PROCEDURE

SWITCH

FUNCTION IN SPECIAL SWITCH MODE

I/O

ON/OFF SWITCH

1When held in, displays the code for current parameter

2Step back to previous parameter, and while held in displays the parameter code. When released, displays the value of the parameter.

3Advance to the next parameter. (same as above)

Increase the value of the current parameter.

XDecrease the value of the current parameter

To set the parameters complete the following steps:

1.This can only be entered from the panel OFF mode.

2.Press and HOLD IN any key EXCEPT the ON/OFF key for three seconds.

3.While Holding key, press and release the ON/OFF key.

You will now be in the programming mode.

CODE

PARAMETER

SET AT:

bss

Blast Soft Stat

33

 

bhs

Blast Hard Stat

12

 

bfs

Blast Freeze Stat

-16

 

sss

Store Soft Stat

33

 

shs

Store Hard Stat

33

 

sfs

Store Freeze Stat

-8

 

bsd

Blast Soft Differential

35

 

bhd

Blast Hard Differential

35

 

bfd

Blast Freeze Differtial

35

 

ssd

Store Soft Differential

35

 

sfd

Store Freeze Differential

35

 

 

 

 

 

bd1

Blast Duration 1 (normally 30 min.)

30

 

bd2

Blast Duration 2 (normally 60 min.)

60

 

bd3

Blast Duration 3 (normally 90 min.)

90

 

bd4

Blast Duration 4 (normally 240 min)

240

 

cab

Cabinet Number

1

 

ala

Alarm Duration

900 (15 min)

ddc

Defrost Duration for Cabinet

Hex. Switch

dic

Defrost Interval for Cabinet

Hex. Switch

ddp

N/A defrost Duration for PoD minutes, Set Manually

 

 

dip

N/A defrost Interval Hours, Set Manually

 

 

det

Defrost Target Temperature

39

 

 

 

 

 

yr

Calander Year Setting

Set Accordingly

 

nth

Calander Month Setting

Set Accordingly

 

day

Calander Day Setting

Set Accordingly

 

hr

Calander Hour Setting

Set Accordingly

 

ute

Calander Minute Setting

Set Accordingly

 

Image 21
Contents Blast Chillers Model Numbers Table of Contents Introduction CCBC-4-35 CCBC-4-35 Chill Temp Blast Chiller Weight CCBC-12-75 Reach-In Blast Chill Refrigeration Data Crated CBBC-12-UA-100 Reach-In Blast Chiller Data Control Panel For CCBC-4-35 Unpacking Instructions Locating Your new Blast Chill Unit Installation Start UP Information HOW to OperateProbe Controlled Blast Chill CYCLE/MODESLoading of Product DefrostOperation Midnight Ticket PrinterDo not hose Blast Chiller HintsService & Troubleshooting Segment Display Alarm CodesTroubleshooting Troubleshooting Troubleshooting Troubleshooting Parts List and Breakdown Drawing of Blast Chillers Page Parts List CCBC-4-35 Blast Chiller 208V 60HZ Single Phase Page Parts List CCBC-12-75 Blast Chiller 208V 60HZ Single Phase Page Parts List CCBC-12-UA-100 Blast Chiller 208V 60HZ 3 Phase General Rules of Thumb Mail To Page Meats Roasted MeatsTurkey/Chicken Casseroles and Stews SeafoodSauces and Gravies Sandwiches/Specialty ItemsVegetables SoupsPotatoes Pasta and Noodles RiceFried Foods CerealsBreakfast Meat PANCAKES/FRENCH TOAST/WAFFLESBreakfast BURRITOS/CREPES Breakfast SandwichesHash BROWNS/OVEN Fries