Cres Cor CCBC-12-75, CCBC-4-35, CCBC12-UA-100 service manual Troubleshooting

Page 25

[Section 5-Troubleshooting ]

[ Page 22 ]

2.Door not shut tight

3.Gaskets leaking

4.Check defrost heater operator (if used):

(a)Defective heater

(b)Blown fuse (if used)

(c)Defective "klixon" if used

5.Check defrost settings:

(a)Check defrost thermostat ("St 5") setting

(b)Check defrost differential ("dt 5") setting

(c)Check Defrost Period Switch on main PCB inside control box

(d)Check Defrost Length Switch on main PCB control box.

6.Check that ambient temperature has not exceeded 100°F or 100% humidity.

Display reads - 58° F

1.Thermocouple is "open" :

(a)If food probe, check the make sure it's plugged into probe receptacle properly

(b)Check for loosened thermocouple wire connection at all connections

(c)Check for broken or cut thermocouple wire

(d)Temperature display not believable - responds in reverse:

-Polarity of thermocouple wire is reversed

Evaporator won't run:

1.Breaker not on (if equipped)

2.Motor overload tripped (if equipped)

3.In post-defrost "Drip" period

4."Fan door" switch is open (if equipped)

5.Blown fuse (if used)

6.Defective contactor (if equipped)

7.Motor defective

Printer problems (if equipped) :

1.Printer doesn't run:

(a)"Link" (jumper) on main PCB not installed

(b)Damaged communications "ribbon" cable

(c)Defective printer

(d)Defective PCB

2.Printer "runs", but no paper comes out:

(a)Check if paper roll is loaded

(b)Check for jammed paper tape -

-Before loading a new roll, make sure free end of tape is pulled completely away from the roll. Remove any paper residue. (The residue will undoubtedly result in a paper jam).

-Carefully remove any paper residue from printer platen, otherwise another jam could occur.

(c)Check for proper tape feed

3.Printer runs, but paper comes out with no printing:

(a)Check if printer has ribbon cartridge installed

(b)Check ribbon - condition may be out of ink, dried out, or torn

Image 25
Contents Blast Chillers Model Numbers Table of Contents Introduction CCBC-4-35 CCBC-4-35 Chill Temp Blast Chiller Weight CCBC-12-75 Reach-In Blast Chill Refrigeration Data Crated CBBC-12-UA-100 Reach-In Blast Chiller Data Control Panel For CCBC-4-35 Unpacking Instructions Locating Your new Blast Chill Unit Installation Start UP Information HOW to OperateProbe Controlled Blast Chill CYCLE/MODESLoading of Product DefrostOperation Midnight Ticket PrinterDo not hose Blast Chiller HintsService & Troubleshooting Segment Display Alarm CodesTroubleshooting Troubleshooting Troubleshooting Troubleshooting Parts List and Breakdown Drawing of Blast Chillers Page Parts List CCBC-4-35 Blast Chiller 208V 60HZ Single Phase Page Parts List CCBC-12-75 Blast Chiller 208V 60HZ Single Phase Page Parts List CCBC-12-UA-100 Blast Chiller 208V 60HZ 3 Phase General Rules of Thumb Mail To Page Roasted Meats MeatsTurkey/Chicken Casseroles and Stews SeafoodSauces and Gravies Sandwiches/Specialty ItemsVegetables SoupsPotatoes Pasta and Noodles RiceFried Foods CerealsBreakfast Meat PANCAKES/FRENCH TOAST/WAFFLESBreakfast Sandwiches Breakfast BURRITOS/CREPESHash BROWNS/OVEN Fries