Cres Cor CCBC12-UA-100, CCBC-4-35, CCBC-12-75 service manual Troubleshooting

Page 26

[ Section 5-Troubleshooting ]

[ Page 23 ]

(c)Check make sure ribbon cartridge is properly installed - both sides snapped in place

4.Printer is printing backwards and all characters reversed

(a)Paper tape is feeding incorrectly over top of printer ribbon. This can readily occur when inserting a ribbon cartridge with paper tape still protruding from the printer. The ribbon must be on top of the paper in order to print correctly.

5.Paper rolls and ribbon cartridges are available from CresCor Authorized Parts Distributors.

Odors inside cabinet:

1.Spilled food inside - clean as required

2.If not being used for a long period of time, turn off, clean interior and keep door open to ventilate. Alternatively after cleaning, place and odor absorbent such as baking soda inside with the door kept closed. Remove before restarting.

Alarm conditions:

1.Cabinet wall temperature above 38°F more than 60 minutes

2.Defrost termination on time instead of temperature

3.Compressor overheating (if temperature is greater than 217°F for 1 minute)

4.Compressor run (if the compressor runs continuously for more than 6 hours in either blast mode or storage mode)

5.Faulty sensor (including food probe)

6.Loss of power for 5 seconds or more

7.Dead battery

Food dried out

1.Uncovered containers

2.Left in storage too long

Food frozen

1.Too long blast cycle

(a)Choose a shorter timed program

(b)Use the probe program

2.Uneven food portions-thinner foods can freeze by the time thicker portions reach temperature

3.Monitor temperatures more frequently if uneven food loads and remove those when reaching end temperature

4.Food probe defective

5.Stat 1 set too warm

Food not cold enough

1.Timed cycle too short

2.Stat 1 set too warm

3.Food probe tip not in center of food

4.Defective probe

Image 26
Contents Blast Chillers Model Numbers Table of Contents Introduction CCBC-4-35 CCBC-4-35 Chill Temp Blast Chiller Weight CCBC-12-75 Reach-In Blast Chill Refrigeration Data Crated CBBC-12-UA-100 Reach-In Blast Chiller Data Control Panel For CCBC-4-35 Unpacking Instructions Locating Your new Blast Chill Unit Installation HOW to Operate Start UP InformationBlast Chill CYCLE/MODES Probe ControlledDefrost Loading of ProductOperation Printer Midnight TicketHints Do not hose Blast ChillerService & Troubleshooting Alarm Codes Segment DisplayTroubleshooting Troubleshooting Troubleshooting Troubleshooting Parts List and Breakdown Drawing of Blast Chillers Page Parts List CCBC-4-35 Blast Chiller 208V 60HZ Single Phase Page Parts List CCBC-12-75 Blast Chiller 208V 60HZ Single Phase Page Parts List CCBC-12-UA-100 Blast Chiller 208V 60HZ 3 Phase General Rules of Thumb Mail To Page Turkey/Chicken MeatsRoasted Meats Sauces and Gravies SeafoodCasseroles and Stews Sandwiches/Specialty ItemsSoups VegetablesPotatoes Fried Foods RicePasta and Noodles CerealsPANCAKES/FRENCH TOAST/WAFFLES Breakfast MeatHash BROWNS/OVEN Fries Breakfast BURRITOS/CREPESBreakfast Sandwiches