PERFORMANCE DATA SHEETS
Base Grille Water Filtration System
Model T1WG2L/T2RFWG2 Capacity 200 Gallons (758 Liters)
Model T1WG2/T2RFWG2 Capacity 200 Gallons (758 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class II*; and against NSF/ANSI Standard 53 for the reduction of Mercury,
Benzene, Toxaphene,
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % |
Aesthetic Effects | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction |
|
|
|
|
|
|
|
|
Chlorine Taste/Odor | 50% reduction | 2.0182 mg/L | 2.0 mg/L ± 10% | 0.06 mg/L | 0.0536 mg/L | 97.03 | 97.34 |
Particulate Class II* | 85% reduction | 1333333 #/mL | At least 10,000 particles/mL | 6600 #/mL** | 2325 #/mL | 99.51 | 99.83 |
Contaminant | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % |
Reduction | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction |
|
|
|
|
|
|
|
|
Lead: @ pH 6.5*** | 0.010 mg/L | 0.1533 mg/L | 0.15 mg/L ± 10% | 0.0005 mg/L | 0.0005 mg/L | 99.67 | 99.67 |
Lead: @ pH 8.5*** | 0.010 mg/L | 0.1400 mg/L | 0.15 mg/L ± 10% | 0.0007 mg/L | 0.0006 mg/L | 99.50 | 99.57 |
|
|
|
|
|
|
|
|
Mercury: @ pH 6.5 | 0.002 mg/L | 0.0058 mg/L | 0.006 mg/L ± 10% | 0.0002 mg/L | 0.0002 mg/L | 96.54 | 96.54 |
Mercury: @ pH 8.5 | 0.002 mg/L | 0.0059 mg/L | 0.006 mg/L ± 10% | 0.0005 mg/L | 0.0003 mg/L | 91.57 | 94.92 |
|
|
|
|
|
|
|
|
Benzene | 0.005 mg/L | 0.0154 mg/L | 0.015 mg/L ± 10% | 0.0012 mg/L | 0.0006 mg/L | 92.22 | 96.34 |
|
|
|
|
|
|
|
|
0.6 mg/L | 1.7571 mg/L | 1.8 mg/L ± 10% | 0.0250 mg/L | 0.0066 mg/L | 98.58 | 99.63 | |
|
|
|
|
|
|
|
|
Toxaphene | 0.003 mg/L | 0.015 mg/L | 0.015 mg/L ± 10% | 0.001 mg/L | 0.001 mg/L | 93.33 | 93.33 |
|
|
|
|
|
|
|
|
Carbofuran | 0.04 mg/L | 0.0819 mg/L | 0.08 mg/L ± 10% | 0.0400 mg/L | 0.0213 mg/L | 51.13 | 74.00 |
|
|
|
|
|
|
|
|
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).
■It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
■Use replacement cartridge T2RFWG2, part #4396841. In Canada, use replacement cartridge T2RFWG2, part #4396841B. 2007 suggested retail price of $39.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
Model T1WG2L: When the filter indicator light changes from green to yellow, order a new filter. When the filter indicator light changes from yellow to red, it is recommended that you replace the filter.
Model T1WG2: Change the water filter cartridge every
6 months depending upon your usage. If the water flow to the water dispenser or ice maker decreases noticeably before
6 months have passed, replace the water filter cartridge more often.
■These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
■Refer to the “Assistance or Service” section for the Manufacturer’s name, address and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply | City or Well |
Water Pressure | 30 - 120 psi (207 - 827 kPa) |
Water Temperature | 33° - 100°F (0.6° - 37.8°C) |
Service Flow Rate | 0.5 gpm (1.9 Lpm) @ 60 psi |
*Class II particle size: 1 um to <5 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
***Compliant for Lead reduction requirements under NSF/ANSI Standard 53 as tested by Pace Analytical Services, Inc. ® NSF is a registered trademark of NSF International.