ResMed 248551/1 Therapy pressure, Tolerance, Sound pressure level, Alarm Volume Range, Conditions

Page 32

Therapy pressure

IPAP: ± 0.5 cm H2O ± 10% of set pressure (end of

tolerance

inspiration)

 

EPAP/PEEP: ± 0.5 cm H2O ± 4% of set pressure

 

CPAP: ± 0.5 cm H2O ± 10% of set pressure

 

Test condition: T mode, IPAP: 40 cm H2O, EPAP: 2 cm

 

H2O, Rise Time: MIN, Fall Time: MIN, Ti: 4.0 sec,

 

Respiratory Rate: 10 bpm, with ResMed calibration cap.

 

 

Sound pressure level

29 dBA as measured according to ISO 17510 – 1:2002.

 

32 dBA with uncertainty of 3 dBA as measured according

 

to ISO 17510 – 1:2007.

 

 

Alarm Volume Range

> 45 dBA - < 85 dBA at 1 meter (3 steps: low, medium, high)

 

 

Dimensions (L x W x H)

230 mm x 170 mm x 120 mm

 

 

Weight

2.1 kg

 

 

Air outlet

22 mm taper, compatible with ISO 5356-1:2004

 

Anaesthetic & Respiratory Equipment - Conical

 

Connectors

 

 

Pressure measurement

Internally mounted pressure transducer

 

 

Flow measurement

Internally mounted flow transducer

 

 

Power supply

AC 100–240V, 50–60Hz, 2.2 A, max. 65 W

 

 

External DC Power

24 V, 3 A

Supply

 

 

 

Internal Battery

Lithium-Ion battery, 14.4 V, 1.6 Ah, 23 Wh

 

Operating hours: 2 h with a new battery under normal

 

conditions (see below).

 

Patient type: home chronic; pressure: IPAP/EPAP 15/5

 

cm H2O; mask type: Ultra Mirage; air tubing: 2 m; leak:

 

0; respiratory rate: 20 bpm; battery capacity: 100%

 

Patient type: hospital acute; pressure: IPAP/EPAP 20/5

 

cm H2O; mask type: Ultra Mirage; air tubing: 2 m; leak:

 

0; respiratory rate: 45 bpm; battery capacity: 100%

 

 

Housing construction

Flame retardant engineering thermoplastic

 

 

Environmental

• Operating temperature: 0°C to 35°C

conditions

• Operating humidity: 10%–95% non-condensing

 

• Storage and transport temperature: -20°C to 60°C

 

(+50°C*)

 

• Storage and transport humidity: 10%–95% non-

 

condensing

 

• Air pressure: 1,100hPa to 680hPa; Altitude: 3,500 m

 

*NONIN XPOD

 

 

Electromagnetic

Product complies with all applicable electromagnetic

compatibility

compatibility requirements (EMC) according to

 

IEC60601-1-2, for residential, commercial, and light

 

industry environments. For further details see “Guidance

 

and manufacturer’s declaration – electromagnetic

 

emissions and immunity” on page 28.

 

 

Air filter

Electro static fibre mesh with TPE frame structure. Bacterial

 

filtration efficiency of 99.540% on area weight 100g/m².

 

 

Air tubing

Flexible plastic, 2 m or 3 m length (22 mm diameter)

 

 

SlimLine air tubing

Flexible plastic, 1.83 m length (15 mm diameter)

 

 

English

Technical specifications

27

Image 32
Contents Stellar User GuideRespiratory Care Solutions Making quality of care easy Stellar 100 Stellar Contents Cleaning and maintenance Introduction Indications for useContraindications Adverse effectsStellar at a glance Internal battery Patient interfaceHumidification ResMed USB stickSetting up for noninvasive use Mobile useSetting up for invasive use Attaching the H4i heated humidifier for noninvasive useHmef Adding supplemental oxygen Working with other optional accessoriesAttaching the pulse oximeter Using the FiO2 monitoring sensor Starting therapy using oxygenStopping therapy using oxygen Connecting a sensor Attaching an antibacterial filterStellar basics About the control panelPerforming a functional test Starting therapyLCD screen Starting therapy Stopping therapyCheck the FiO2 monitoring sensor if in use Check pulse oximeter if in useTurning off the power Working with alarmsTailoring treatment setup options Using mask-fitUsing the menus Enu Alarm Settings Alarm Volume Enu OptionsOptions On, Auto Setup menu Configuration MenuParameter Description Info menu Event SummaryUsed Hours Device InformationDaily Cleaning and maintenanceData management Weekly MonthlyReplacing the air filter DisinfectionTroubleshooting Alarm troubleshootingMultipatient use ServicingProblem / possible cause Action LCD Internal Battery Empty LCD High Temperature 10, 11, 12LCD System Failure LCD Over PressureProblem / possible cause Action LCD Circuit disconnected LCD Internal Battery LowLCD Low Minute Ventilation LCD Low Respiratory Rate!, High Respiratory RateOther troubleshooting Problem / possible cause Solution Device does not start when you breathe into the maskDevice does not stop when you remove your mask Treatment pressure seems highTechnical specifications Alarm Volume Range Dimensions L x W x HWeight Air outlet Power supplyAir travel requirements IECClassifications Vrms Symbols General warnings and cautionsGeneral warnings and cautions Limited warranty Product Warranty periodApac