Vermont Casting DVBR42, DVBR36 manual Rear Wall Vent Installations Twist Lock Pipe

Page 14

DVBR Series Direct Vent Gas Fireplace

20” (506 mm)

Max.

Top View Flat Installation

FP1188

Fig. 19 Rear vent application, no elbows.

20” (506 mm) Max.

Top View Corner Installation

FP1188

Fig. 20 Rear vent application, one 45° elbow.

Rear Wall Vent Installations -

Twist Lock Pipe

Step 1

Locate and cut the vent opening in the wall.

For combustible walls first frame in opening. (Fig. 21)

NOTE: When using flex vent, the opening will have to be measured according to the 1” (25 mm) rise in 24” (610 mm) vertical run.

Combustible Walls: Cut a 10³⁄”H x 9³⁄” W (265 mm x 240 mm) hole through the exterior wall and frame as shown. (Fig. 21)

Noncombustible Walls: Hole opening should be 7¹⁄” (191 mm) diameter.

Zero clearance sleeve is only required for combustible walls.

Step 2

Measure wall thickness and cut zero clearance sleeve parts to proper length (Maximum 12” / 305mm). As- semble sleeve to its maximum opening (10³⁄” x 9³₈”) and attach to firestop assembly. (Fig. 22)

Step 3

Measure the horizontal length requirement for the vent- ing including a 2” (51 mm) overlap, i.e. from the elbow to the outside wall face plus 2” (51 mm). (Fig. 20)

Vent Opening - Combustible Wall

9³⁄"

(240 mm)

10³⁄"

Framing

Detail

(265 mm)

Fireplace Hearth

Vent Opening - Noncombustible Wall

7¹⁄" Dia.

(191 mm)

Fireplace Hearth

VO584-100

Fig. 21 Locate vent opening on wall.

 

Max. Length

 

12” (294 mm)

 

#8 Screws (2)

 

Firestop

#8 Screws (2)

 

#8 Screws

 

(2)

 

Adjustable Zero

 

Clearance Sleeve

CFM135a

Fig. 22 Adjustable zero clearance sleeve.

Step 4

Install the 4” (102 mm) vent to the appliance collar and secure with three (3) sheet metal screws. Install the 7” (175 mm) vent pipe to the appliance collar and secure with three (3) sheet metal screws. It is not necessary to seal this connection. If a 45° elbow is being used attach the elbow to the appliance in the same manner then at- tach the venting to the elbow.

It is critical that there is no downward slope away from the appliance when con- necting the vent or elbow.

Step 5

Guide the venting through the vent hole as you place the appliance in its installed position. Guide the 4”

(102 mm) and 7” (175 mm) collar of the vent termina- tion into the outer ends of the venting. Do not force the termination. If the vent pipes do not align with the termination, remove and realign the venting at the appli- ance flue collars. (Fig. 23) Attach the termination to the wall as outlined in the instruction sheet supplied with the termination.

14

20000584

Image 14
Contents DVBR42 Table of Contents Installation Instructions Please Read the Following CarefullyFireplace Dimensions Installed as Top Vent Framing DimensionsFireplace Dimensions Installed as Rear Vent Mantels Locating Your FireplaceClearance to Combustibles ApplianceFraming and Finishing Gas Line InstallationHearth Final FinishingRemote Switch Installation EB-1 Electrical BoxOptional Top Vent Application DVBR36General Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationGeneral Information Assembling Vent Pipes Canadian InstallationsUSA Installations Flex Vent PipesRear Wall Vent Applications How to Use the Vent GraphTwist Lock Pipes Rear Wall Vent Installations Twist Lock Pipe Zero clearance sleeve is only required for combustible wallsRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall ApplicationsTotal angular variation 270 Horizontal run reductionVertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall Installation Flex Vent Pipe StepBelow Grade Installation Vertical Through-the-Roof ApplicationsVertical Through-the-Roof Installation DownwardMin 610 mm Venting Components Operating Instructions Glass CleaningReplacement of Ceramic Hearth Panels Glass InformationInstallation of Logs Ember Material Placement Lava RockInspecting the Venting System Flame & Temperature AdjustmentFlame Characteristics Top logs must be placed properly onto notchesCorrect flame appearance for DVBR36 model Lighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting Honeywell VS8421 Remove window frame assembly before service workTroubleshooting the Gas Control System Fuel Conversion Instructions Valve Conversion Honeywell ValvePilot Conversion SIT Natural GasPilot Conversion PSE Burner and Burner Compartment MaintenanceCleaning the Standing Pilot Control System Brass TrimDVBR36/42 DescriptionDVBR36/42 Optional Fk-12 Fan Hook-up Optional AccessoriesRemote Controls Ceramic Refractory PanelsDecorative Face Kit Decorative Glass PanelsDecorative Frame Trims Model Beam ColorDvbr Series Direct Vent Gas Fireplace Dvbr Series Direct Vent Gas Fireplace Limited Lifetime Warranty CFM Corporation