DVBR Series Direct Vent Gas Fireplace
Operating Instructions
Glass Information
Only glass approved by CFM Corporation may be used for replacement.
•The use of any
•Care must be taken to avoid breakage of the glass.
•Do not operate appliance with glass front removed, cracked or broken.
•Replacement glass (complete with gasket) is available through your CFM Corporation dealer and should only be installed by a licensed qualified service person.
Glass Frame Removal
1.Turn off gas.
2.Let the fireplace cool if it has been operating.
3.Remove valve cover. (Fig.47)
4.Release the two (2) clamps at the bottom of the window frame by pulling back on the clamp handles. (Fig. 48)
5.Lift off the glass frame as shown. (Fig. 48)
6.To reinstall glass follow the above procedure in re- verse.
Valve Cover |
Valve |
Pins |
Locating Holes |
Fig. 47 Valve cover location.
Glass Cleaning
It is necessary to clean the glass periodically. During
20000584
| Glass Frame |
| Fireplace |
| Front |
| Clamps |
| Glass |
| Panel |
| Glass |
| Panel |
| Pull Clamp |
| Hook |
| |
Fig. 48 | Glass panel removal. |
two or three times with a
Clean glass after first two weeks of operation.
Do not clean glass when hot. Do not use abrasive cleaners. Do not strike or slam the glass.
Replacement of Ceramic Hearth Panels
1.Remove glass.
2.Remove two (2) hex nuts securing grate to hearth pan. (Fig. 49)
3.Set left and right panels on hearth and bring towards front of unit.
4.Replace grate assembly.
| Grate | Burner |
|
|
|
| |
Hearth Panels |
|
| |
|
| Front of Unit | H100 |
Fig. 49 | Hearth panel location. |
| |
|
|
| 23 |