Vermont Casting DVBR42, DVBR36 manual Total angular variation 270, Horizontal run reduction

Page 16

DVBR Series Direct Vent Gas Fireplace

3 x 90°

3 x 90°

Elbows

Elbows

FP1176

 

Fig. 26

Maximum three (3) 90° elbows per installation.

 

36"

 

(914mm)

 

Max.

 

36"

 

(914mm)

 

Max.

 

FP1177

Fig. 27

Maximum horizontal runwith no rise.

If a 90° elbow is used in the horizontal vent run (level height maintained) the horizontal vent length is reduced by 36” (914mm). (Fig. 28, 29) This does not apply if the 90° elbows are used to increase or redirect a vertical rise. (Fig. 26)

Example: According to the vent graph (Page 15) the maximum horizontal vent length in a system with a

7¹⁄₂” (191mm) rise is 20” (508mm) and if a 90° elbow is required in the horizontal vent it must be reduced to 17’ (5.2m).

90o

AB

A + B = 17' (Max.)

7'6"

FP1178

Fig. 28 Horizontal run reduction.

 

 

7’

 

A

(178cm)

 

 

 

10’

 

 

(254cm)

B

 

 

 

A + B = 17’ Max.

 

8’

 

 

(244cm)

 

 

 

V584-201

Fig. 29

Maximum vent run with elbows.

 

In Figure 28 & 29, dimension A plus B must not be greater than 17’ (5.2m)

The maximum number of 45° elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run.

For each 45° elbow installed in the horizontal run, the length of the horizontal run MUST be reduced by 18” (457mm). This does not apply if the 45° elbows are installed on the vertical part of the vent system.

The maximum number of elbow degrees in a system is 270°. (Fig. 30)

Example:

Elbow 1

=

90°

Elbow 2

=

45°

Elbow 3

=

45°

Elbow 4

=

90°

Total angular variation

=

270°

 

1 + 2 + 3 + 4 = 270°

1

1

2

2

3

3

4

4

FP1180

Fig. 30 Maximum elbow usage.

16

20000584

Image 16
Contents DVBR42 Table of Contents Installation Instructions Please Read the Following CarefullyFireplace Dimensions Installed as Top Vent Framing DimensionsFireplace Dimensions Installed as Rear Vent Locating Your Fireplace Clearance to CombustiblesMantels ApplianceGas Line Installation HearthFraming and Finishing Final FinishingRemote Switch Installation EB-1 Electrical BoxOptional Top Vent Application DVBR36General Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesTwist Lock Pipes How to Use the Vent GraphRear Wall Vent Applications Rear Wall Vent Installations Twist Lock Pipe Zero clearance sleeve is only required for combustible wallsRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall ApplicationsTotal angular variation 270 Horizontal run reductionVertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall Installation Flex Vent Pipe StepBelow Grade Installation Vertical Through-the-Roof ApplicationsVertical Through-the-Roof Installation DownwardMin 610 mm Venting Components Glass Cleaning Replacement of Ceramic Hearth PanelsOperating Instructions Glass InformationInstallation of Logs Ember Material Placement Lava RockFlame & Temperature Adjustment Flame CharacteristicsInspecting the Venting System Top logs must be placed properly onto notchesCorrect flame appearance for DVBR36 model Lighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting Honeywell VS8421 Remove window frame assembly before service workTroubleshooting the Gas Control System Fuel Conversion Instructions Valve Conversion Honeywell ValvePilot Conversion PSE Natural GasPilot Conversion SIT Maintenance Cleaning the Standing Pilot Control SystemBurner and Burner Compartment Brass TrimDVBR36/42 DescriptionDVBR36/42 Optional Accessories Remote ControlsOptional Fk-12 Fan Hook-up Ceramic Refractory PanelsDecorative Glass Panels Decorative Frame TrimsDecorative Face Kit Model Beam ColorDvbr Series Direct Vent Gas Fireplace Dvbr Series Direct Vent Gas Fireplace Limited Lifetime Warranty CFM Corporation