Installation of Logs

 

 

Ember Material Placement

 

Log Chart

 

 

Separate the ember material into small pieces, roughly

Logs

DVBR36

DVBR42

1/2” in diameter and place onto the burner in front of

the front logs. Do NOT pack down, leave in fluffy, loose

Left Log

20008817

20008508

condition for most realistic ember effect.

Right Log

20008819

20008510

Lava Rock

Right Rear Log

20008818

20008509

Left Cross Log

20008820

20008515

 

Log Top Right

--

 

B29

The lava rock provided with this fireplace must be placed

Right Cover Log

20008822

20008515

on the firebox base around the burner assembly.

Left Rear Log

20008513

20008816

 

Center Log

20008821

20008514

Under no circumstances should this lava

Left Front Log

20008823

20008823

rock be placed on any part of the burner

Left Cover Log

20008512

20008512

assembly.

1 . Remove front glass. (See “Glass Remov-

 

Right Rear Log

al” Section, Fig. 48)

 

 

 

2. Remove logs from packaging.

 

Left Rear

 

As with all plastics — these are

 

Log

 

not toys and should be kept

 

 

 

away from children and infants.

 

 

3. Place Right Rear Log onto the two pem studs on the rear log support. Place the Left Rear Log on the left side of the rear log support and push the log up against the Right Rear Log. (Fig. 50)

4. Place the Left Log on the pem studs on the left side of the burner. Place the Right Log on the pem studs on the right side of the burner. (Fig. 51)

5. Place the front edge of the Left Cover

 

 

Log on the front top edge of the burner

 

 

between the last two left tines of the

 

LG340

grate. Allow the bottom edge of the log to

Fig. 50

Place Right and Left Rear Logs on rear log support.

sit on the hearth. Place the Right Cover

 

 

Log between the right two tines and rest

 

Right Log

the log up against the front face of the

 

 

burner. (Fig. 52)

 

 

6. Place the Center Log between the sec- ond and third tines as shown. Place the v-notch on the left side of the Center Log against the left tine of the grate. Rest the right side of the Center log up against the face of the Right Log. (fig. 52)

7. Place the left Cross Log over the pin of the Right Rear Log and the pin of the Left Log. (Fig. 3)

8. DVBR42 only. Place the Right Cross Log

 

over the Right Rear Log and the Right

 

Log as shown. (Fig. 53) When positioned

Left Log

correctly, the right rear flame will come up

LG390

through the hole in the Right Cross log.

Fig. 51 Place Left and Right Logs on pem studs on burner.

Carefully adjust the log as needed to al-

low the flame to come through the hole.

24

20000584

Image 24
Contents DVBR42 Table of Contents Installation Instructions Please Read the Following CarefullyFireplace Dimensions Installed as Top Vent Framing DimensionsFireplace Dimensions Installed as Rear Vent Locating Your Fireplace Clearance to CombustiblesMantels ApplianceGas Line Installation HearthFraming and Finishing Final FinishingRemote Switch Installation EB-1 Electrical BoxOptional Top Vent Application DVBR36General Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesHow to Use the Vent Graph Twist Lock PipesRear Wall Vent Applications Rear Wall Vent Installations Twist Lock Pipe Zero clearance sleeve is only required for combustible wallsRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall ApplicationsTotal angular variation 270 Horizontal run reductionVertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall Installation Flex Vent Pipe StepBelow Grade Installation Vertical Through-the-Roof ApplicationsVertical Through-the-Roof Installation DownwardMin 610 mm Venting Components Glass Cleaning Replacement of Ceramic Hearth PanelsOperating Instructions Glass InformationInstallation of Logs Ember Material Placement Lava RockFlame & Temperature Adjustment Flame CharacteristicsInspecting the Venting System Top logs must be placed properly onto notchesCorrect flame appearance for DVBR36 model Lighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting Honeywell VS8421 Remove window frame assembly before service workTroubleshooting the Gas Control System Fuel Conversion Instructions Valve Conversion Honeywell ValveNatural Gas Pilot Conversion PSEPilot Conversion SIT Maintenance Cleaning the Standing Pilot Control SystemBurner and Burner Compartment Brass TrimDVBR36/42 DescriptionDVBR36/42 Optional Accessories Remote ControlsOptional Fk-12 Fan Hook-up Ceramic Refractory PanelsDecorative Glass Panels Decorative Frame TrimsDecorative Face Kit Model Beam ColorDvbr Series Direct Vent Gas Fireplace Dvbr Series Direct Vent Gas Fireplace Limited Lifetime Warranty CFM Corporation