Vermont Casting DVBR42, DVBR36 manual Troubleshooting Honeywell VS8421

Page 28

DVBR Series Direct Vent Gas Fireplace

Troubleshooting – Honeywell VS8421

 

 

 

Remove window frame assembly before service work

 

 

START

 

 

 

 

CHECK

 

 

 

 

 

 

 

 

 

 

 

 

Gas Supply On

 

NO

 

 

Supply Line Hooked Up

 

 

 

 

 

 

 

 

 

 

Shutoff Valve Open

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lockout Has Engaged. Wait 60

 

 

 

 

 

 

 

 

 

Seconds And Try Again.

 

 

 

 

 

 

 

 

For Spark At Electrode While

 

 

 

Pilot Lights With Piezo

 

 

 

 

 

 

 

NO

 

 

 

Depressing Piezo

 

 

 

Ignitor

 

 

 

 

 

1/8" Gap To Pilot Hood Needed.

 

 

 

 

 

 

 

 

All Wiring Connections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace Piezo Ignitor

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Air In The Lines

 

 

 

 

 

 

 

 

Thermopile Needs A Min.

 

 

 

 

 

 

 

 

 

325mv. Adjust Pilot Flame

 

 

 

 

 

 

 

 

 

Height.

 

 

 

 

 

 

 

 

All Wiring Connections

 

 

 

PILOT STAYS LIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

Replace Thermopile

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermocouple Needs A Min. Of

 

 

 

 

 

 

 

 

 

14mv

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve Is Turned On

 

 

 

 

 

 

 

 

Wall Switch Is Not Turned On.

 

 

 

PILOT LIGHTS MAIN

 

 

 

 

 

 

 

NO

 

 

 

Watch For Grounded Wires!

 

 

 

BURNER

 

 

 

Thermopile Needs A Min. 325mv.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plugged Burner Orifice

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

Defective Valve. Turn To Pilot,

 

 

 

 

 

 

 

 

 

Meter Should Read Greater Than

 

 

 

 

 

 

 

 

 

100mv. If Not, Replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

20000584

Image 28
Contents DVBR42 Table of Contents Installation Instructions Please Read the Following CarefullyFireplace Dimensions Installed as Top Vent Framing DimensionsFireplace Dimensions Installed as Rear Vent Locating Your Fireplace Clearance to CombustiblesMantels ApplianceGas Line Installation HearthFraming and Finishing Final FinishingRemote Switch Installation EB-1 Electrical BoxOptional Top Vent Application DVBR36General Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesTwist Lock Pipes How to Use the Vent GraphRear Wall Vent Applications Rear Wall Vent Installations Twist Lock Pipe Zero clearance sleeve is only required for combustible wallsRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall ApplicationsTotal angular variation 270 Horizontal run reductionVertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall Installation Flex Vent Pipe StepBelow Grade Installation Vertical Through-the-Roof ApplicationsVertical Through-the-Roof Installation DownwardMin 610 mm Venting Components Glass Cleaning Replacement of Ceramic Hearth PanelsOperating Instructions Glass InformationInstallation of Logs Ember Material Placement Lava RockFlame & Temperature Adjustment Flame CharacteristicsInspecting the Venting System Top logs must be placed properly onto notchesCorrect flame appearance for DVBR36 model Lighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting Honeywell VS8421 Remove window frame assembly before service workTroubleshooting the Gas Control System Fuel Conversion Instructions Valve Conversion Honeywell ValvePilot Conversion PSE Natural GasPilot Conversion SIT Maintenance Cleaning the Standing Pilot Control SystemBurner and Burner Compartment Brass TrimDVBR36/42 DescriptionDVBR36/42 Optional Accessories Remote ControlsOptional Fk-12 Fan Hook-up Ceramic Refractory PanelsDecorative Glass Panels Decorative Frame TrimsDecorative Face Kit Model Beam ColorDvbr Series Direct Vent Gas Fireplace Dvbr Series Direct Vent Gas Fireplace Limited Lifetime Warranty CFM Corporation