Vermont Casting DVBR36, DVBR42 Below Grade Installation, Vertical Through-the-Roof Applications

Page 19

Below Grade Installation

When it is not possible to meet the required vent terminal clearances of 12” (305 mm) above grade level, a snorkel kit is recommended. It allows installation depth down

to 7” (178 mm) below grade level. The 7” (178 mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall.

Ensure the sidewall venting clearances are ob- served. If venting system is installed below ground, we recommend a window well with adequate and proper drainage to be installed around the termina- tion area.

DVBR Series Direct Vent Gas Fireplace

Do not back fill around snorkel.

A clearance of at least 4” must be main- tained between the snorkel and the soil.

If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fas- ten brackets to wall first, then secure to snorkel with self drilling #8 x 1/2 sheet metal screws. It will be necessary to extend vent pipes out as far as the protruding wall face. (Fig. 38)

If installing a snorkel, a minimum 24” (610 mm) vertical rise is necessary. The maximum horizontal run with the 24” vertical pipe is 36” (914 mm). This measurement is taken from the collar of the fireplace (or transition elbow) to the face of the exterior wall. See the Sidewall Venting Graph for extended horizontal run if the vertical exceeds 24” (610 mm).

1.

Establish vent hole through the wall (Fig. 31)

2.

Remove soil to a depth of approximately 16”

 

(406mm) below base of snorkel. Install drain pipe.

Foundation Recess

Watertight Seal

Around Pipe

Snorkel

Wall Screws

Sheet Metal

Screws

BG401

 

Install window well (not supplied). Refill hole with 12”

 

(305mm) of coarse gravel leaving a clearance of ap-

 

proximately 4” (102 mm) below snorkel. (Fig. 37)

3.

Install vent system.

4.

Ensure a watertight seal is made around the vent

 

pipe coming through the wall.

5.

Apply high temperature sealant caulking (supplied)

 

around the 4” and 7” snorkel collars.

6.

Slide the snorkel into the vent pipes and secure to

 

the wall.

7.

Level the soil so as to maintain a 4” (102 mm) clear-

 

ance below snorkel. (Fig. 37)

Fig. 38 Snorkel installation, recessed foundation.

Vertical Through-the-Roof Applications

This gas fireplace has been approved for:

Vertical installations up to 40’ (12m) in height. Up to a 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. (Fig. 41)

Up to two 45° elbows may be used within the hori- zontal run. For each 45° elbow used on the horizon- tal plane, the maximum horizontal length must be reduced by 18” (450mm).

Example: Maximum horizontal length:

Zero Clearance

Sleeve if Required

Firestop

7” Pipe

7DVSK (Snor- kel)

4” Clearance

Min.

Window

Well

Gravel

Drain

Foundation Wall

*A minimum of 24” (608 mm) vertical pipe must be installed when using the 7TDVSKS kit.

BG400

No elbows

=

10’ (3 m)

1 x 45° elbow

=

8.5’ (2.6 m)

2 x 45° elbows

=

7’ (2.1 m)

A minimum of an 8’ (2.5 m) vertical rise is required.

Two sets of 45° elbow offsets may be used within the vertical sections. From 0 to a maximum of 8’ (2.5 m) of vent pipe can be used between elbows. (Fig. 42)

7DVCS supports offsets. (Fig. 44) This application will require that you first determine the roof pitch and use the appropriate starter kit. (Refer to Venting Components List)

The maximum angular variation allowed in the sys- tem is 270°. (Fig. 42)

The minimum height of the vent above the highest point of penetration through the roof is 2’ (610mm). (Fig. 45) Refer to Note 2, Page 11.

Fig. 37 Below grade installation.

20000584

19

Image 19
Contents DVBR42 Table of Contents Please Read the Following Carefully Installation InstructionsFraming Dimensions Fireplace Dimensions Installed as Top VentFireplace Dimensions Installed as Rear Vent Appliance Locating Your FireplaceClearance to Combustibles MantelsFinal Finishing Gas Line InstallationHearth Framing and FinishingEB-1 Electrical Box Remote Switch InstallationDVBR36 Optional Top Vent ApplicationLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Flex Vent Pipes Canadian InstallationsUSA Installations General Information Assembling Vent PipesTwist Lock Pipes How to Use the Vent GraphRear Wall Vent Applications Zero clearance sleeve is only required for combustible walls Rear Wall Vent Installations Twist Lock PipeVertical Sidewall Applications Rear Wall Vent Installations Flex Vent PipeHorizontal run reduction Total angular variation 270Always install horizontal venting on a level plane Vertical Sidewall Installation Twist Lock PipeStep Vertical Sidewall Installation Flex Vent PipeVertical Through-the-Roof Applications Below Grade InstallationDownward Vertical Through-the-Roof InstallationMin 610 mm Venting Components Glass Information Glass CleaningReplacement of Ceramic Hearth Panels Operating InstructionsLava Rock Installation of Logs Ember Material PlacementTop logs must be placed properly onto notches Flame & Temperature AdjustmentFlame Characteristics Inspecting the Venting SystemCorrect flame appearance for DVBR36 model To Turn Off Gas To Heater Lighting and Operating InstructionsRemove window frame assembly before service work Troubleshooting Honeywell VS8421Troubleshooting the Gas Control System Valve Conversion Honeywell Valve Fuel Conversion InstructionsPilot Conversion PSE Natural GasPilot Conversion SIT Brass Trim MaintenanceCleaning the Standing Pilot Control System Burner and Burner CompartmentDescription DVBR36/42DVBR36/42 Ceramic Refractory Panels Optional AccessoriesRemote Controls Optional Fk-12 Fan Hook-upModel Beam Color Decorative Glass PanelsDecorative Frame Trims Decorative Face KitDvbr Series Direct Vent Gas Fireplace Dvbr Series Direct Vent Gas Fireplace Limited Lifetime Warranty CFM Corporation