#8

Maximum Length

SCREWS(2)

12" (294mm)

 

#8

ADJUSTABLE

ZERO CLEARANCE

SCREWS(2)

SLEEVE

 

 

#8

 

SCREWS(2)

ADJUSTABLE ZERO

FIRESTOP

CLEARANCE SLEEVE

 

 

Fig. 12

STEP 3

Measure from fireplace collar to face of outside wall (add 2" for vent pipe overlap. Mark pipes and cut to length. It is very important that the two pipes are flush with the outside wall once the fireplace is in its final location. Fig. 13.

STEP 4

Slip 4" and 7" pipes onto respective flue collars. Make sure to fix to the fireplace collar the 4" pipe with three (3) screws before fixing the 7" pipe on the 7" collar. Both pipes must be on a level plane. Fig. 13.

STEP 5

Guide the vent termination 4" collar into the 4" pipe then the 7" collar into the 7" pipe. Do not force the venting into position. If the pipes do not line up with the termination collars, disassemble pipes and reattach to the fireplace collar. (Fig. 13)

STEP 6

Secure fireplace to floor through floor holes and adjustable frame drywall strip (nailing flange) to frame. (See Framing & Finishing Section)

VERTICAL SIDEWALL APPLICATIONS

Vent Starter Kit 7DVSK, plus Transition Elbow 7DVRT90 must be used in Vertical Sidewall installations. The 4" pipe must be centred inside the 7" pipe coming off the 7DVRT90 transition elbow.

Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to.

The graph showing the relationship between vertical and horizontal side wall venting will help to determine the various vent lengths allowable. Fig. 19.

Minimum clearance between vent pipes and combustible materials is one (1") inch (25

mm)on top, bottom and sides unless otherwise noted.

When vent termination exits through foundation less than 20" below siding outcrop, the vent pipe must flush up with the siding. A 7DVSS must also be used.

It is always best to locate the fireplace in such a way that minimizes the number of offsets and horizontal vent length.

The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace to the face of the outer wall.

Horizontal plane means no vertical rise exists on this portion of the vent assembly.

For some installations, it may be desireable to have some amount of the horizontal vent run immediately after the fireplace. A verti- cal rise must be used but can be located anywhere in the vent system, to meet the perimeters identified in the venting graph.

The maximum horizontal vent run is 20 feet (6100mm) when the vertical vent rise is 7.5 feet (2286mm). Fig. 14

MAXIMUM

20ft.

(6100mm)

48"

 

 

(1220mm)

 

15ft.

12"

 

VENT

(305

 

(4572

 

mm)

 

TERMINATION

mm)

 

 

 

 

Vertical Dimension 8ft. minimum when horizontal run is

7.5'

90"

20 ft.

(2286mm)7DVT90

ELBOW

SIDE VIEW

Fig. 14

- 10 -

Image 10
Contents DVRS3 Dvrsl Dvrsr Table of Contents Installation and Operating Instructions Locating Your Majestic GAS FireplaceMantel Chart Fireplace DimensionsMantels Framing and Finishing GAS SpecificationsClearance to Combustibles Final FinishingGAS Line Installation Remote Switch InstallationGeneral Venting Termination Clearances Rear Wall Installations Rear Venting ApplicationsVertical Sidewall Applications Maximum120 Vertical Sidewall Installation HOW to USE the Vent GraphVertical Sidewall Venting Graph SCREWS2 Below Grade Installations InstallationVertical Through Roof Applications Vertical Thru the Roof Installation DVR Series Crimped Venting Components General Information on Assembling Twist Lock Vent Pipes Vent Opening Combustible Wall Vertical Sidewall Installations Sidewall Venting Graph Vent Sidewall Installation Zero Clearance Sleeve if Required Firestop Two sets of 45 degree elbow offsets within these Vertical Through the Roof Installation DVR Series Twist Lock Venting Components Louvre Removal Front Glass Removal Side Glass RemovalGlass Cleaning Ceramic Refractory InstallationEmber Material Placement Installation of LogsLava Rock Lighting Instructions To Turn OFF GAS to FireplaceTrouble Shooting the GAS Control System SIT 820 Nova Millivolt ValveMaintenance Flame AdjustmentFlame Characteristics Cleaning the Standing Pilot Control SystemReplacement Parts DVRS3 & Dvrsl / Dvrsr Replacement Parts List DVRS3/DVRSL/DVRSR DescriptionOptions Remote ControlFAN KIT FK24

DVRSL, DVRSR, DVRS3 specifications

Vermont Castings has been a trusted name in the manufacturing of high-quality wood and gas stoves and fireplaces for decades. Among their extensive lineup of gas-burning appliances, the DVRS3, DVRSR, and DVRSL models stand out for their impressive combination of efficiency, aesthetic appeal, and user-friendly features. These models exemplify Vermont Castings' commitment to craftsmanship, innovation, and environmental responsibility.

The DVRS3 is a powerful direct vent gas stove that offers cozy warmth to any living space. It features a large firebox capable of accommodating different log options and provides a maximum input of up to 30,000 BTUs. One key feature of the DVRS3 is its advanced heat exchange system, which enhances heat distribution and efficiency, ensuring that more of the heat generated is released into the room rather than lost through the chimney. Additionally, the stove is designed with a full-width cast iron door and large ceramic glass window, providing an unobstructed view of the flames for a captivating ambiance.

The DVRSR model brings similar qualities but with a more contemporary design. This direct vent stove is engineered to fit seamlessly into modern homes while delivering efficient heating. With a maximum output of up to 25,000 BTUs, it maintains an eco-friendly approach, having been certified for low emissions. The DVRSR also comes equipped with various customization options, including different finishes and decorative options, allowing homeowners to match their stove with their interior design.

For those looking for a space-saving alternative without sacrificing performance, the DVRSL model is ideal. This slim-profile direct vent gas stove is designed to fit in tighter spaces while still offering impressive heating capabilities. With a maximum BTU output of 30,000, the DVRSL is packed with features such as an easy-to-use electronic ignition and remote control capability, allowing users to adjust the flame height and temperature settings with ease.

Each of these models is equipped with Vermont Castings' signature technology that promotes safety, efficiency, and reliability. From built-in safety shut-off systems to durable materials that withstand the test of time, the DVRS3, DVRSR, and DVRSL models are designed to provide years of dependable service. Whether you value traditional aesthetics or modern design, Vermont Castings has engineered these gas stoves to meet the diverse needs of today’s homeowners, combining style, functionality, and peace of mind in each product.