Vermont Casting DVRSR Flame Adjustment, Flame Characteristics, Inspecting the Venting System

Page 32

FLAME ADJUSTMENT

For fireplaces equipped with Hi/Lo valves, flame adjust- ment is accomplished by rotating the Hi/Lo adjustment knob located near the centre of the gas control. Fig. 71.

 

I

H

 

 

Turn

 

Turn clockwise

counterclockwise

 

 

to lower

to increase

 

 

flame height.

flame height.

 

 

 

 

LO

 

 

Fig. 71

FLAME CHARACTERISTICS

It is important to periodically perform a visual check of the pilot and the burner flames. Com- pare them to the pictorials illustrated below (Fig. 72, 73 and 74). If any of the flames appear abnormal call a service person.

3/8" - 1/2"

Fig. 72

LEFT

SIDE

VIEW

Fig. 73

RIGHT

SIDE

VIEW

Fig. 74

INSPECTING THE VENTING SYSTEM

This appliance venting system was designed and con- structed to develop a positive flow adequate to remove flue gases to the outside atmosphere.

Any foreign objects in the venting system, except those designed specifically for the venting system, may cause spillage of flue gases.

To inspect the venting system, make sure the main gas valve is off. Remove glass door (See Glass Door Re- moval). Using a flashlight, check the area above the baffle in the combustion dome. Clean if necessary.

MAINTENANCE

It is important to keep the burner and the burner compartment clean. This must be done periodically, at least once per season.

The optional FK24 fan does require periodic cleaning. Check the area under the control door and in front of the fan and wipe or vacuum at least once a month during the operating season.

Clean any optional brass trim using a soft cloth lightly dampened with lemon oil. Do not use water or household cleaners on any brass components.

Contact your local dealer to arrange an annual service program.

CLEANING THE STANDING PILOT

CONTROL SYSTEM

The burner and control system consists of:

main burners

gas orifices

pilot assembly

thermopile

millivolt gas valve

 

Most of these components may require only an occasional checkup and cleaning and some may require adjustment. If repair is necessary, it should be performed by a qualified technician.

1.Turn off pilot light at gas valve side

2.Let fireplace cool if it has been running.

3.Remove glass side. (see Glass Removal)

4.Remove logs,

LOGS MAY BE HOT

5.Vacuum burner compartment especially around orifice primary air openings.

6.Visually inspect pilot. Brush or blow away any dust or lint accumulation.

7.Reinstall logs.

8.Ignite pilot - see Operating Section of Manual.

8. Reinstall glass side.

To obtain proper operation, it is imperative that the pilot and burner's flame characteristics are steady, not lifting or floating.

Typically, the top 3/8" or 1/2" of the thermopile should be engulfed in the pilot flame. See Fig. 72.

To adjust pilot burner (by a Qualified Service Representative)

1.Remove pilot adjustment cap.

2.Adjust pilot screw to provide properly sized flame.

3.Replace pilot adjustment cap.

The primary air shutter is set at factory and should only be adjusted (if necessary) by a qualified service person.

- 32 -

Image 32
Contents DVRS3 Dvrsl Dvrsr Table of Contents Installation and Operating Instructions Locating Your Majestic GAS FireplaceMantels Fireplace DimensionsMantel Chart GAS Specifications Clearance to CombustiblesFraming and Finishing Final FinishingGAS Line Installation Remote Switch InstallationGeneral Venting Termination Clearances Rear Wall Installations Rear Venting ApplicationsVertical Sidewall Applications Maximum120 Vertical Sidewall Venting Graph HOW to USE the Vent GraphVertical Sidewall Installation SCREWS2 Below Grade Installations InstallationVertical Through Roof Applications Vertical Thru the Roof Installation DVR Series Crimped Venting Components General Information on Assembling Twist Lock Vent Pipes Vent Opening Combustible Wall Vertical Sidewall Installations Sidewall Venting Graph Vent Sidewall Installation Zero Clearance Sleeve if Required Firestop Two sets of 45 degree elbow offsets within these Vertical Through the Roof Installation DVR Series Twist Lock Venting Components Louvre Removal Front Glass Removal Side Glass RemovalGlass Cleaning Ceramic Refractory InstallationLava Rock Installation of LogsEmber Material Placement Lighting Instructions To Turn OFF GAS to FireplaceTrouble Shooting the GAS Control System SIT 820 Nova Millivolt ValveFlame Adjustment Flame CharacteristicsMaintenance Cleaning the Standing Pilot Control SystemReplacement Parts DVRS3 & Dvrsl / Dvrsr Replacement Parts List DVRS3/DVRSL/DVRSR DescriptionFAN KIT FK24 Remote ControlOptions

DVRSL, DVRSR, DVRS3 specifications

Vermont Castings has been a trusted name in the manufacturing of high-quality wood and gas stoves and fireplaces for decades. Among their extensive lineup of gas-burning appliances, the DVRS3, DVRSR, and DVRSL models stand out for their impressive combination of efficiency, aesthetic appeal, and user-friendly features. These models exemplify Vermont Castings' commitment to craftsmanship, innovation, and environmental responsibility.

The DVRS3 is a powerful direct vent gas stove that offers cozy warmth to any living space. It features a large firebox capable of accommodating different log options and provides a maximum input of up to 30,000 BTUs. One key feature of the DVRS3 is its advanced heat exchange system, which enhances heat distribution and efficiency, ensuring that more of the heat generated is released into the room rather than lost through the chimney. Additionally, the stove is designed with a full-width cast iron door and large ceramic glass window, providing an unobstructed view of the flames for a captivating ambiance.

The DVRSR model brings similar qualities but with a more contemporary design. This direct vent stove is engineered to fit seamlessly into modern homes while delivering efficient heating. With a maximum output of up to 25,000 BTUs, it maintains an eco-friendly approach, having been certified for low emissions. The DVRSR also comes equipped with various customization options, including different finishes and decorative options, allowing homeowners to match their stove with their interior design.

For those looking for a space-saving alternative without sacrificing performance, the DVRSL model is ideal. This slim-profile direct vent gas stove is designed to fit in tighter spaces while still offering impressive heating capabilities. With a maximum BTU output of 30,000, the DVRSL is packed with features such as an easy-to-use electronic ignition and remote control capability, allowing users to adjust the flame height and temperature settings with ease.

Each of these models is equipped with Vermont Castings' signature technology that promotes safety, efficiency, and reliability. From built-in safety shut-off systems to durable materials that withstand the test of time, the DVRS3, DVRSR, and DVRSL models are designed to provide years of dependable service. Whether you value traditional aesthetics or modern design, Vermont Castings has engineered these gas stoves to meet the diverse needs of today’s homeowners, combining style, functionality, and peace of mind in each product.