TROUBLE SHOOTING THE GAS CONTROL SYSTEM
SIT 820 NOVA MILLIVOLT VALVE
GLASS DOOR TO BE REMOVED BEFORE SERVICE WORK
START
GAS SUPPLY ON
▼
LIGHT PILOT WITH
PIEZO IGNITION
YES
NO
NO
CHECK
▼ |
|
| • SHUTOFF VALVE OPEN |
| • CONFIRM GAS |
|
|
|
|
▼ | • ELECTRODE GAP MIN. 1/8" |
| |
| • ELECTRODE CRACKED |
| • ELECTRODE CABLE ATTACHED |
| • PIEZO IGNITOR GENERATES |
| SPARK |
| • ELECTRODE CABLE NOT |
| GROUNDED |
|
|
▼
PILOT STAYS ON
YES
NO
▼
•FLAME ENGULFING THERMOCOUPLE BY 3/8"
•THERMOCOUPLE ATTACHED TO VALVE
•MNIMUM MILLIVOLT:
OPEN CIRCUIT 18MV
CLOSED CIRCUIT 5MV
•VENT SAFETY SWITCH TIGHT AND NO SHORTS
(FOR UNITS EQUIPPED WITH VENT SAFETY SWITCH)
▼
MAIN BURNER ON
NO
▼
•REMOTE SYSTEM ON
•REMOTE SYSTEM WIRE SHORTING OUT
•MINIMUM MILLIVOLT: OPEN CIRCUIT 300MV CLOSED CIRCUIT 165MV
•FLAME ENGULFING THERMOPILE/THERMOCOUPLE
•VALVE IS IN ON POSITION
- 31 -