Beko HBG70X manual USE and Maintenance

Page 17

the 4 sleeves C and 4 screws D as indicated.

• Fixing to the wall

Drill the holes A respecting the distances indicated (Fig.2). Fix the appliance to the wall and align it in horizontal posi- tion to the wall units. When the appliance has been adjusted, definitely fix the hood using the screws A (Fig.5). For the various installations use screws and screw anchors suited to the type of wall (e.g. reinforced concrete, plasterboard, etc.). If the screws and screw anchors are provided with the product, check that they are suitable for the type of wall on which the hood is to be fixed.

• Fixing the decorative telescopic flue

warning! Caution! If your appliance model features the lower connector with a tab, before fixing it in place bend the tab inwards using a pair of pliers, as illustrated in figure 5, step1.

Arrange the electrical power supply within the dimensions of the decorative flue. If your appliance is to be installed in the ducting version or in the version with external motor, prepare the air exhaust opening. Adjust the width of the support bracket of the upper flue (Fig.3). Then fix it to the ceiling using the screws A (Fig.3) in such a way that it is in line with your hood and respecting the distance from the ceiling indicated in Fig.2. Connect the flange C to the air exhaust hole using a connection pipe (Fig.5 - Stage 2). Insert the upper flue into the lower flue. Fix the lower flue to the hood using the screws B provided (Fig.5 - Stage 2), extract the upper flue up to the bracket and fix it with the screws B (Fig.3). To transform the hood from a ducting version into a filtering version, ask your dealer for the charcoal filters and follow the installation instructions.

• Filtering version

Install the hood and the two flues as described in the paragraph for installation of the hood in ducting version. To assemble the filtering flue refer to the instructions contained in the kit.

If the kit is not provided, order it from your dealer as accessory. The filters must be applied to the suction unit positioned inside the hood. They must be centred by turning them 90 degrees until the stop catch is tripped (Fig.8).

USE AND MAINTENANCE

We recommend that the cooker hood is switched on before any food is cooked. We also recommend that the appliance is left running for 15 minutes after the food is cooked, in order to thoroughly eliminate all contaminated air.

The effective performance of the cooker hood depends on constant maintenance; the anti-grease filter and the active carbon filter both require special attention.

The anti-grease filter is used to trap any grease particles suspended in the air, therefore is subject to saturation (the time it takes for the filter to become saturated depends on the way in which the appliance is used).

- To prevent potential fire hazards, the anti-grease filters should be washed a minimum of every 2 months (it is possible to use the dishwasher for this task).

- After a few washes, the colour of the filters may change. This does not mean they have to be replaced.

If the replacement and washing instructions are not followed, the anti-grease filters may present a fire hazard.

The active carbon filters are used to purify the air which is released back into the room. The filters are not washable or re-usable and must be replaced at least once every four months. The active carbon filter saturation level depends on the frequency with which the appliance is used, the type of

cooking performed and the regularity with which the anti- grease filters are cleaned.

Clean the cooker hood frequently, both inside and outside, using a cloth which has been dampened with denatured alcohol or neutral, non-abrasive liquid detergents.

The light on the cooker hood is designed for use during cooking and not for general room illumination. Extended use of the light reduces the average duration of the bulb.

Replacing halogen light bulbs (Fig.6)

To replace the halogen light bulbs B, remove the glass pane C using a lever action on the relevant cracks.

Replace the bulbs with new ones of the same type. Caution: do not touch the light bulb with bare hands.

Commands (fig.9) mechanical the key symbols are explained below:

A = LIGHT B = OFF

C = SPEED I D = SPEED II E = SPEED III.

Commands (fig.10) luminous the key symbols are explained below:

A = LIGHT B = OFF

C = SPEED I D = SPEED II E = SPEED III

F = AUTOMATIC STOP TIMER - 15 minutes (*).

If your appliance does not have the INTENSIVE speed function, press key E for two seconds and it will be activated for 10 minutes after which it will return to the previously set speed. When the function is active the LED flashes. To interrupt it before the 10 minutes have expired press key E again.

By pressing key F for two seconds (with the hood switched off) the“clean air”function is activated. This function switches the appliance on for ten minutes every hour at the first speed. As soon as this function is activated the motor starts up at the first speed for ten minutes, During this time keyF and key C must flash at the same time. After ten minutes the motor switches off and the LED of keyF remains switched on with a fixed light until the motor starts up again at the first speed after fifty minutes and keysF and C start to flash again for ten minutes and so on.

By pressing any key for the exclusion of the hood light the hood will return immediately to its normal functioning (e.g. if key D is pressed the “clean air” function is deactivated and the motor moves to the 2nd speed straight away. By pressing key B the function is deactivated).

(*)The “automatic stop timer” delays stopping of the hood, which will continue functioning for 15 minutes at the operating speed set at the time this function is activated.

• Active carbon/grease filter saturation:

-When button A flashes at a frequency of 2 seconds, the grease filters must be cleaned.

-When button A flashes at a frequency of 0.5 seconds, the carbon filters must be replaced.

After the clean filter has been replaced, the electronic memory must be reset by pressing button A for approximately 5 seconds, until the light on the button stops flashing.

- 17 -

Image 17 Contents
70cm Glass Chimney Hood Page Page Page Italiano Istruzioni PER L’INSTALLAZIONEGeneralità Avvertenze PER LA SicurezzaFissaggio a parete USO E ManutenzioneFissaggio dei raccordi telescopici decorativi Versione filtranteAllgemeines Deutsch DSicherheitshinweise Vor Anschluss des Modells an das StromnetzSchutzhandschuhe anlegen Elektroanschluss InstallationsanleitungIsolierklasse AchtungAustausch der Halogenlampen Abb.6 Benutzung UND WartungFiltrationsversion Sugerencias Para LA Seguridad Español EGeneralidades Instrucciones Para LA Instalación USO Y Mantenimiento = botón Timer Parada AUTOMáTICA 15 MinutosSustitución de las lámparas halógenas Mandos Français F Instructions Pour L’INSTALLATION Géneralités Conseils Pour LA SécuritéEmploi ET Entretien Pince comme illustré à la phaseFixation murale Fixation des raccords télescopiques de décorationRemplacement des lampes halogènes Safety PrecautionCommandes English GBApplicable for external air evacuation Installation InstructionsInsulation class Please noteUSE and Maintenance Commands HOW to Obtain Service Under the Manufacturers Warranty Republic of Ireland Nederlands NL Installatie InstructiesAlgemeen VeiligheidsvoorschriftenWaarschuwing Gebruik EN OnderhoudBevestiging aan de muur FilterversieAdvertências Para a Segurança Português PVervanging van de halogeenlampen Afb.6 Kontroller Afb.11Antes de ligar o modelo à rede eléctrica Istruções Para a InstalaçãoNão permita que as crianças brinquem com o aparelho Classe de isolamentoFixação na parede USO E ManutençãoFixação das junções telescópicas decorativas Versão filtranteComandos Nando a tecla B a função desativa-sePage 3LIK0836