Enviro EG 33 owner manual Routine Maintenance and Technical, Do not Clean Glass When HOT

Page 16

ROUTINE MAINTENANCE and TECHNICAL

Periodically check to ensure that your system is clean.

Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with no yellow tips.

OPENING THE DOOR

Turn unit off and wait until the appliance has cooled down. Open the lower louver panel. Undo the three bolts at the bottom corners and center of the door. Swing door out, then lift up and out to remove.

Ensure the door is properly fastened after cleaning before attempting to re-light the appliance.

CLEANING THE GLASS

DO NOT CLEAN GLASS WHEN HOT

It will be necessary to clean the ceramic glass periodically. During a cold start up, condensation will sometimes form on the glass, this is a normal condition with all gas fireplaces and stoves. However, this condensation can allow dust and lint to cling to the glass surface. Initial paint curing of the appliance can leave behind a slight film on the glass. This is a temporary problem. It is therefore recommended that the glass be cleaned initially after about the first two weeks of use.

To clean the door use a mild glass cleaner and a soft cloth. Abrasive cleaners will damage the glass and gold surfaces.

TO REPLACE DOOR GLASS

The glass in this appliance is ceramic. If the glass is damaged or broken a factory replacement must be fitted.

TO REPLACE:

Open door, remove the glass carefully.

Install the new piece of glass with the large bulb in the gasket tape against the unit. Place the joint in the tape in a bottom corner. Close door

Glass must be purchased from an Envirogas dealer. No substitute materials are allowed.

CLEANING THE INSIDE OF THE FIREBOX

Remove the log carefully from the firebox. Gently remove the embers and place on a piece of paper towel. Until ready to replace.

Vacuum the bottom of the firebox thoroughly. Carefully clean off any dust on the logs and brick panels and remove any lint from the main burner and pilot burner.

After carefully replacing the log and embers in their correct positions, and the door has been resealed, re-light the pilot, following the instructions on the attached label.

CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE

Depending upon the amount of use, cleaning should be required no more than two or three times per season.

REMOVING BURNER CONTROLS:

1.Shut of gas supply to appliance.

2.Disconnect gas line from the valve.

3.Open the door and remove the log. Remove the burner tray assembly by removing the two screws on either side of the tray. Pull tray up at the back, lift tray out and towards the front.

4.Remove the brick panel as per instructions. Undo the

(6) six screws that hold the burner control tray onto the base of the unit. Lift the control tray, up on the left side and pull out.

5.Installation is the reverse

CAUTION:

Bleed lines before lighting and light pilot with door open

ADJUSTING VENTURI AIR SETTINGS

There is a separate venturi air shutter for each burner The venturis have been set for installation at sea level.

To adjust for high altitude: open the lower louvers, Locate the venturis between the burner and control trays. Loosen the 2 set screws with a long screwdriver and rotate the air shutters to the correct setting.

16

Image 16
Contents For Your Safety What to do if YOU Smell GASSafety Precautions GeneralTable of Contents Code ApprovalsDeciding Where to Locate Your Stove DimensionsMobile Home ClearancesFraming Dimensions InstallationIncluding Finished Hearth Height Page Required Mantle Clearances Vent RestrictionsFlue Collar Installation Vent Terminal ClearancesVertical Termination Planning Your InstallationVenting Terminals Cannot be Recessed Into a Wall or Siding Horizontal Installation FIG-13 FIG-14 Vertical Installation FIG-16 FIG-17FIG-21 FIG-22 Installation of Logset and Embers Optional Ceramic PanelsFor Your Safety Read Before Operating Operating InstructionsRoutine Maintenance and Technical Do not Clean Glass When HOTTrouble Shooting Problem Possible Cause SolutionGAS Line Connection Never USE AN Open Flame for Leak TestingOrifice SIZES, Pressures and BTU’S Installing or Removing the Blower Installing Remote Thermostat or Wall SwitchWire Size Maximum Length ElectricalRemove the two 2 main burner orifices using a ½ deep socket Fuel ConversionWarranty Sign and verify that work and information are correctInstallation Data Sheet Mail Address envirofire@home.com