ELECTRICAL

The ENVIROGAS EG 22.Z/CLEARANCE .DV. will operate with no external power supply. These models have a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burner.

The appliance when installed, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the USA.

Operation of the fan increases the efficiency and the heat output of the appliance.

CAUTION

Label all wires prior

to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS.

For your protection against electrical shock, this unit should be properly grounded.

INSTALLING OR REMOVING THE BLOWER

The blower does not require lubrication.

1.Turn the unit off and make sure the unit is cool before you start to install the fan assembly.

2.Open the bottom louver assembly to access gas control compartment.

3.Place the blower assembly already installed on the fan-mounting bracket, in the center, rear of the appliance. Place blower over the two screws provided on the base of the appliance.

4.Install the electrical box on either the left side of the appliance. This electrical box will have the fan controller already installed on the box.

5.Wire the blower and fan controller to the wiring diagram supplied on this page. (Page 19)

6.This unit must be hard wired to household wiring and should be properly fixed to the appliance with a stain relief connector.

INSTALLING REMOTE THERMOSTAT OR WALL SWITCH

RECOMMENDED WIRE SIZE for thermostat installation: 18 gauge, 2 wire solid core, Low Voltage wire. (Bell wire)

1.Install the 18 Gauge wire supplied to the two terminals on the thermostat or remote wall switch.

2.Connect the other end of the wire to the gas valve using the two outside terminals on the front of the gas valve. Use the terminals marked (TP/TH and TH) as shown below.

RECOMMENDED MAXIMUM LEAD LENGTH

(TWO WIRE) WHEN USING WALL

THERMOSTAT

WIRE SIZE

MAXIMUM LENGTH

 

 

14 GAUGE

100 FEET

 

 

16 GAUGE

64 FEET

 

 

18 GAUGE

40 FEET

 

 

20 GAUGE

18 FEET

 

 

19

Image 19
Contents What to do if YOU Smell GAS For Your SafetyGeneral Safety PrecautionsCode Approvals Table of ContentsClearances Deciding Where to Locate Your StoveDimensions Mobile HomeFraming Dimensions InstallationIncluding Finished Hearth Height Page Vent Restrictions Required Mantle ClearancesVent Terminal Clearances Flue Collar InstallationVertical Termination Planning Your InstallationVenting Terminals Cannot be Recessed Into a Wall or Siding Horizontal Installation FIG-13 FIG-14 FIG-16 FIG-17 Vertical InstallationFIG-21 FIG-22 Optional Ceramic Panels Installation of Logset and EmbersOperating Instructions For Your Safety Read Before OperatingDo not Clean Glass When HOT Routine Maintenance and TechnicalProblem Possible Cause Solution Trouble ShootingGAS Line Connection Never USE AN Open Flame for Leak TestingOrifice SIZES, Pressures and BTU’S Electrical Installing or Removing the BlowerInstalling Remote Thermostat or Wall Switch Wire Size Maximum LengthFuel Conversion Remove the two 2 main burner orifices using a ½ deep socketSign and verify that work and information are correct WarrantyMail Address envirofire@home.com Installation Data Sheet