INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
Min 35½” (90cm) - 36“ (91cm)
For Canada, min 363/8” (92.5cm)
| Min 31½” (80cm) |
|
|
|
|
|
|
| |
|
|
|
| |
|
|
|
| |
between the top of the cooktop | Maximum 13” | |||
and a horizontal combustible surface | (33cm) | |||
|
|
|
|
|
|
|
|
|
|
Minimum 18”
(46cm)
Positioning the Range
Fig.7-1 shows the minimum recommended distances and clearances from the range to nearby surfaces.
You MUST provide adequate clearances between the range and adjacent combustible surfaces. These dimensions MUST be met for safe use of your range.
The location of the electrical outlet and pipe opening (see Gas Pipe and Electric Outlet Locations) may be adjusted to meet specific requirements.
| Min 35 | 15⁄16” (91cm) |
|
| |
| Max 36 | 7/8” (93.7cm) |
|
|
|
For electrical and |
| ||||
|
|
|
|
| |
|
|
| gas supply zone |
| |
|
Min 35½” (90cm) - 36“ (91cm) recommended to allow for moving the range.
For Canada, min 363/8” (92.5cm)
44¼” (112.4cm)
28” (71.1cm)
261/8” (66.7cm)
24” (61cm) |
| Open oven door |
33⁄8” (8.5cm) without | shown dotted |
side extension fitted |
|
A gap of at least 3” (7.5 cm) should be left between each side of the range ABOVE the cooktop level and any adjacent vertical surface.
The cooktop surround should be level with, or above, any adjacent work surface.
For
A minimum space of 31½” (80cm) is required between the top of the cooktop and a horizontal combustible surface. The maximum depth for cabinets installed above cooktops is 13’’ (33 cm).
The depth of the range is 283/8’’ (72 cm) overall
Any range hood should be installed in accordance with the hood manufacturer’s instructions.
For safety reasons curtains must not be sited immediately behind the range.
We recommend a gap of 35½” (90 cm) – 36” (91 cm (for Canada 363/8” (92.5 cm)) between cupboards to allow for moving the range.
USA only: If a flush fit is required, install the range up to the cupboard at one side then install the cupboard the other side.