Amana ARTC7114* Installing 3-Wire Power Cord, Neutral terminal connect wire, Power terminals

Page 7
Neutral terminal connect wire

Range has been grounded at the factory to the center (nickel plated) terminal of the terminal block in accordance with the National Electrical Code (section 2560). When a separate ground is required by local code, disconnect the grounding strap from the terminal block. Ground frame by connecting a grounding wire to range frame using only the grounding screw removed from the grounding strap.

Neutral terminal connect wire

with white insulation

Power terminals

(240 V)

Ground strap

Power lead connect wire with black or red insulation and brass terminal

Terminal Block

Terminal block is approved for copper wire connection only, NOT aluminum wiring. If aluminum house wiring is to be connected, the following procedure is suggested.

1.Connect length of copper building wire to range terminal block with ring terminals.

2.Splice copper wires to aluminum wiring using connectors which are designed certified by Underwriter’s Laboratories and recognized for joining copper to aluminum. Follow the connector manufacturer’s recommended procedure.

3.Wire used, location and enclosure of splices must conform to local codes.

Installing 3-Wire Power Cord

Refer to power cord instructions if available for additional information.

1.Remove rear wire cover on rear of range.

2.Place strain relief (winged clamp) in cord access hole below terminal block.

Strain relief is supplied with cord. Place wings through hole, entering from bottom. Screw holes in clamp should be below mounting panel. Place cord through strain relief.

3.Attach neutral (center) or white wire to center terminal on terminal block.

4.Attach power lead, red wire or black wire to left side power terminal.

5.Attach power lead, red wire or black wire to the right side power terminal.

6.After wires have been placed on terminals, attach with hex nuts provided.

Firmly tighten to ensure proper electrical connection.

7.Place screw through strain relief and tighten.

8.Replace rear wire cover.

Wires from range

(Number of wires on each terminal can vary)

 

A

 

 

 

 

B

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wires from power cord

A—Power lead terminal (Connect black or red insulated wire and secure with brass nut.)

B—Neutral terminal (Connect insulated white insulated wire and secure with brass nut.)

Installing 3-wire Power Cord

7

Image 7
Contents Customer Please Read Manual Before Operating Range InstallerARTC7114 ARTC7003 Model Identification Parts and AccessoriesService Asure Extended Service PlanALL RANGES CAN TIP INJURY TO PERSONS COULD RESULT IMPORTANT SAFETY INFORMATIONINSTALL ANTI-TIP BRACKETS PACKED WITH RANGE SEE INSTALLATION INSTRUCTIONSGLASS/CERAMIC COOKING SURFACES SELF-CLEANING OVENSPrecautions SURFACE COOKING UNITSCabinet Opening InstallationPacking Material Range LocationLine Voltage Requirements Power Supply LocationPower Cord Requirements Irregular Cabinet and Countertop HeightsGround strap Installing 3-Wire Power CordNeutral terminal connect wire Power terminalsNumber of wires on each terminal can vary Installing 4-Wire Power CordLevel Range Converting 3-Wire to 4-Wire Power CordAnti-tip Bracket Installation Removal and Replacement of RangeOperation Range FeaturesF E D Introduction cooking is complete, press switch towardsOven Cooking Methods Element and Fan LocationPreparing to Cook with Smoothtop Elements Surface Element SettingsCooking with Surface Elements Temperature Utensil Material CharacteristicCooking Utensils TypePads and Knobs Oven SignalsOven Switches Electronic Oven ControlOther Features Oven Rack Placement Setting Electronic ClockSetting Electronic Timer Resetting and Canceling TimerBaking or Convection Baking CLEANBake Pan Placement Convection Pan PlacementInterrupt Self-Clean Cycle Self-CleaningPrepare for Self-clean Cycle Self-cleaningFood Cooking GuideBaking Guide Poultry Roasting GuideRack position Beef and Pork Roasting GuideBroiling Guide ThicknessConvection Broiling Guide Convection Baking GuideConvection Beef and Pork Roasting Guide Convection Poultry Roasting GuideOven temperature Fahrenheit Removing Storage Drawer Care and CleaningRemoving Oven Door Replacing Oven LightGeneral Directions CleaningPart Materials to UseTo Prevent Cleaning Smoothtop RangetopProblem CauseCheck Before Calling for ServiceLIMITED THIRD THRU FIFTH YEAR WARRANTY ON GLASS/CERAMIC TOP WarrantyCOOKING PRODUCTS excluding wall ovens FULL ONE YEAR WARRANTY LIMITED SECOND YEAR WARRANTY ON ALL PARTSSelf-Cleaning Setting Electronic ClockSetting Electronic Timer Adjusting Factory Set Baking Temperature