Napoleon Grills V 600, V 450 manual Leak Testing Instructions

Page 36

36

Leak Testing Instructions

WARNING! A leak test must be performed annually and each time a cylinder is hooked up or if a part of the gas system is replaced.

Warning! Never use an open flame to check for gas leaks. Be certain no sparks or open flames are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, damage to prop- erty, serious bodily injury, or death.

Leak testing: This must be done before initial use, annually, and whenever any gas components are replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak Testing Dia- gram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.

Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator, hose, manifolds and valves.

Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one recommended by the Napoleon Customer Care department and have the grill inspected by a certified gas installer.

If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill inspected by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.

www.napoleongrills.com

Image 36
Contents Prestige V 450/600 Napoleon Gas Grill President’s Limited Lifetime Warranty Safe Operating Practices Propane Cylinder Specifications General InformationGas Hook-Up Instructions Leak Testing Instructions Lighting Instructions Off PositionCooking Instructions Infrared Grilling Chart Infrared HeatCleaning Instructions Maintenance Instructions Adjusting the air shutterReplacement Screen N565-0002 Troubleshooting Problem Possible Causes SolutionAbove grill surface over the pilot burner to feel Ordering Replacement Parts Warranty InformationRecord information here for easy reference Avertissement Garantie À VIE Limitée DU Président Conditions Et LimitationsPratiques Sécuritaires D’utilisation Information Générale Spécifications Pour La Bonbonne De PropaneBranchement De La Bonbonne Test De Détection De Fuites Instruction D’allumage AVERTISSEMENT! Ouvrez le couvercleOuvrez ensuite la soupape d’alimentation en gaz lentement Instructions D’opération Chaleur Infrarouge Tableau de cuisson à l’infrarougeNettoyage Instructions D’entretien Pour ajuster le volet d’airPage Problème Causes possibles Solutions Guide De DépannageÉcrans de rechange N565-0002 Deux minutes. Réallumez le brûleur et réglez-le à high Commande De Pièces De Rechange Information Sur La GarantieGetting Started Pour CommencerPage 2A. PF 2B. PF PF600 Disposable grease tray jetable du récipient à graisseTo Gas Supply House ’arrivée De Gaz Rotisserie Kit Assembly Instruction Instructions D’assemblage De L’ensemble De RôtissoireLeak Testing Instructions Test De Détection De Fuites Parts List / Liste Des Pièces Description PF450Parts List / Liste Des Pièces Parts List / Liste Des Pièces PF450 Description PF600 Parts List / Liste Des Pièces Parts List / Liste Des Pièces Description PF600 Page Accessories & Parts Order Form BON DE Commande Pour PIÈCES/ACCESSOIRES Page