46945 Hose Kit
Attach Hoses to Control Valve
NOTICE
■If hydraulic lines are not connected as shown in the mount installation manual or tractor man- ual, the loader control valve may be damaged. A blocked outlet (RETURN) or improper hose con- nection will cause pressurized oil to enter the return circuit and damage the valve or the tractor hydraulic system.
1.Attach 90° end of hoses (2) to the IN, OUT, and PBY ports on the control valve.
2.Route hoses over hose guide (as shown in Figure 15), under right side of platform, and over right rear axle.
2.46947 Hose, 120” x 3/4 JICF x 7/8 JICF
Figure 16. Control Valve Hose Connections
Install Hydraulic Fittings and Hoses
1.Locate the hydraulic ports on the rear of the trac- tor as shown in Figure 17.
2.Remove tube and fittings from the PBY, PRESSURE, and RETURN ports.
RETURN
PRESSURE
PBY
DP3
Figure 17. Tractor Hydraulic Connections
12 Hydraulic Installation | MAN0041 (Rev. 4/4/2008) |
|
|