1023583 HOSE KIT
General Description
These set up instructions are for operating the LU126 or LU132 loader using single lever control valve mounted to the right loader mount as shown in Figure
43.To use this hydraulic connection the hoses must be connected between the control valve and the trac- tor hydraulic system located at the rear of the tractor.
NOTE: After the hydraulics and loader are install on the tractor, check the clearance between the top of the exhaust pipe and the loader boom when the loader is raised. If there is interference, a weather cap will need to be installed. See Page 6 for installation instructions.
NOTICE
■If hydraulic lines are not connected as shown in this manual, the control valve may be damaged. A blocked outlet (RETURN) or improper hose con- nection will cause pressurized oil to enter the return circuit and damage the valve.
DP10
Figure 43. Control Valve Installed (Typical)
Install Hydraulic Fittings to Control Valve
1.Remove
2.Install PBY conversion plug (18) and elbow (17), supplied with hose kit, into the side of the control valve.
3.Attach elbow (5) to the fitting in the IN port of the control valve.
5.313032 Elbow, 3/4 JICM x 3/4 JICF 90°
17.60 Elbow, 3/4 JICM x 7/8 ORBM
18.346143
Figure 44. Cable Control Valve Fitting Installation
24 Hydraulic Installation | MAN0041 (Rev. 4/4/2008) |
|
|