3M 2273ME-iD, 2250ME-iD manual Locating in Directional Peak Mode, Passive, Auxiliary

Page 22

4.Press Power [SK Toggle] until the desired frequency is displayed in the soft key command [9] (“Power” 50, 50L, 50H, or 100).

5.Press Locate [5] to return to Locate mode.

All export receivers default to 50 Hz.

To set the receiver to detect 60 Hz signals refer to Enabling/Disabling Frequencies section of this manual.

Passive

The receiver (without a 3M Dynatel Transmitter 2200) can be used to detect some CATV cables (31.5 KHz). (A horizontal-scan television NTSC must be turned on to generate this frequency.)

1.Press Locate [5]

2.Press Cable/Pipe [SK]

3.Press Freq [SK]

4.Press Pasv [SK Toggle]

5.Press Locate [5] to return to Locate mode.

Auxiliary

Auxiliary frequencies are signals generated from remote location transmitters, or frequency generating transmitters.

1.Press Locate [5]

2.Press Cable/Pipe [SK]

3.Press Freq [SK]

4.Press Aux [SK Toggle] until the desired frequency is displayed in the softkey command [9] (“Aux” 512, 560, 333 Hz, or user defined frequencies).

5.Press Locate [5] to return to Locate mode.

Locating in Directional Peak Mode

The following are instructions for locating a buried pipe or cable using the direct connect method and the directional peak (DirPk) mode. Other methods of connection and tracing features are explained in previous sections.

1.Insert the ground rod into the ground, perpendicular to the suspected target path.

22

78-8130-6151-8-E

Image 22
Contents 3M Dynatel Contents 78-8130-6151-8-E About This Manual Safety InformationIntended Use Transmitter Battery Installation Quick StartCleaning Receiver Battery InstallationAA Alkaline Batteries Twist cap to open battery compartment Service and Accessories Transmitter Keypad and Connector DefinitionsRechargeable Battery Maximum Transmitter OutputReceiver Key Pad Definitions Menu Screens Main Menu78-8130-6151-8-E Select Depth Units Configuring The ReceiverSetting the Receiver Clock Selecting a LanguageEnabling/Disabling Frequencies Menu 6 + MoreSK + Setup SK + + More» SK + Locate Freq SKMenu 6 + MoreSK + Setup SK + + More» SK + Tone Freq SK Selecting External Jack Frequencies Tone FrequenciesFiltering Power Frequency Interference Selecting Locating AudioTransmitter Connections Buried Cables And PipesDirect Connect Method Dyna-Coupler Method Induction Method Receiver Modes Mode + Directional Peak DirPk SK ToggleMode + DirNull SK Toggle Directional PeakSpecial Peak Mode + Spl Pk SK ToggleMode + IndPk SK Toggle Inductive Peak IndPkExpanded Mode Depth and Current EstimateFrequencies PowerActive Passive Locating in Directional Peak ModeAuxiliary 78-8130-6151-8-E 78-8130-6151-8-E Locating Active Duct Probes Sondes Determining ADP DepthTransmitter Setup Buried Sheath Faults Earth/Return FaultsPinpointing the Buried Fault Green Band Model Initial Configuration 3M Electronic Markers 3M EMS iD MarkersLocating 3M EMS Markers Alert Mode 3M Dynatel Models 2250ME-iD and 2273ME-iD onlyMenu 6 + Setup SK + Marker Type SK Enabling/Disabling Marker TypesSingle Marker Locate Dual Marker LocateMarker Depth Estimate ID Marker DepthDepth of Passive, Non-iD Marker Creating New Templates Menu 6 + Data/Templat SK + User Templat SK78-8130-6151-8-E Editing Templates Menu 6 + Write Mode SK Writing iD MarkersModifying Marker Data to be Programmed Reading iD Markers Serial Number and Software Version GPS OperationActivation Key Inputting the GPS Activation KeyMenu SK + Setup SK + More SK + More SK + Com SK Toggle Capturing the GPS Coordinates Capture Mode / ModeCommunicating with the GPS unit Path Mapping with GPS Create Trace TemplatesSending Path Information to GPS Device Select Com Port SettingMenu6 + Com SK + GIS SK or PDA SK Write History SK Reviewing Marker HistoryRead History Menu 6 + Data/Templat SK + Read History SKConnection Diagrams Aerial Faults ToningOther Applications Cable Identification 3M Dynatel PC Tool Kit Help ModeReceiver Setup Menu 6 + More SK + Help SKProduct Description Product Description And Optional AccessoriesSelf Test Of Receiver Menu 6 + More SK + Self Test SKPackage Contents Optional 3M Dynatel AccessoriesReceiver Specifications SpecificationNear-Surface 60 cm 24 Ball Marker M 40 in Pwr, WtrMax w/external DC source Transmitter SpecificationsExternal DC source 40%Track and Trace Solutions