3 — OPERATION
Speed Buttons
The SPEED buttons along the lower right side of the control panel must be pressed and held while selecting boom functions. Four speeds are available to control the positioning of the boom lift.
Boom Rotation CW/CCW Buttons
Pressing and holding a desired SPEED button and the BOOM ROTATION CW or CCW button at the same time enables the boom to rotate in the direction selected. The boom will rotate through 700 degrees until the buttons are released or the stop is reached.
Boom Raise/Down Buttons
Pressing and holding a desired SPEED button and the
LOWER BOOM RAISE or UPPER BOOM RAISE button at
the same time will raise the selected boom. Pressing a desired SPEED button and the LOWER BOOM DOWN or UPPER BOOM DOWN button at the same time will lower the selected boom. Boom motion continues until the buttons are released or until each boom reaches a hard stop or a safe travel limit.
Boom Extend/Retract Buttons
Pressing and holding a desired SPEED button and the BOOM EXTEND button at the same time extends the telescopic boom. Pressing and holding a desired SPEED button and the BOOM RETRACT button at the same time retracts the boom. Boom motion continues until the buttons are released or until the boom reaches a hard stop or a safe travel limit.
Jib Raise/Down Buttons
Pressing and holding a desired SPEED button and the JIB RAISE button at the same time will raise the jib boom. Pressing a desired SPEED button and the JIB DOWN button at the same time will lower the jib boom. Boom motion continues until the buttons are released or until the jib boom reaches a hard stop or a safe travel limit.
Platform Tilt Buttons
Press and hold any SPEED button and the desired PLATFORM TILT button at the same time to level the work platform (levels the platform only, not the boom lift).
115 volt Outlet
The 115 Volt AC outlet is provided for running electrical power tools from the work platform. A connecting power cord must be plugged into a suitable power source. The power plug is located on the trailer frame, in front of the accessory equipment stowage plate. The outlet is rated for a