GLOBUG 4-SPOT —TROUBLESHOOTING (LAMPS)
Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, please take a remedial action following the diagnosis based on the Lamp Troubleshooting (Table 4) information shown below.
If the problem cannot be remedied, please leave the unit just as it is and consult or company's service department.
TABLE 4. LAMP TROUBLESHOOTING
SYMPTOM | POSSIBLE PROBLEM | SOLUTION | |
|
|
| |
| Are couplers not securely connected? | Connect coupler correctly. | |
|
|
| |
| Is generator lamp switch turned off? | Turn on switch. | |
|
|
| |
| Is lamp loose? | Screw lamp securely into socket. | |
|
|
| |
| Are connectors not properly connected? | Connect disconnected contactor. | |
|
|
| |
| Are any other electric appliances (other |
| |
Lamp does not light. | than light tower) plugged into power | Unplug all other appliances. | |
source? |
| ||
|
| ||
|
|
| |
| Is generator voltage not normal | Repair or replace generator. | |
| voltage - 120 VAC)? | ||
|
| ||
|
|
| |
| Is model of lamp not compatible? | Use genuine MQ lamp. | |
|
|
| |
| Is lamp not cool enough to light again? |
| |
| (Interval of 20 to 30 minutes is required | Wait for lamp to cool down. | |
| before turning on lamp again) |
| |
|
|
| |
| Is generator voltage not normal | Repair or replace generator. | |
Lamp only lights for a | voltage - 120 V)? | ||
| |||
short time. | Is ambient temperature too high (more than | Move lamp where there is proper | |
| |||
| 104 °F (40 °C)? | ventilation. | |
|
|
|
PAGE 28 — GLOBUG