Multiquip GB114BC Globug Lighting System General Information, Balloon Envelopes, Alarm Buzzer

Page 20

GLOBUG LIGHTING SYSTEM — GENERAL INFORMATION

The Multiquip GloBug Lighting System is a general purpose floodlight tower intended for emergency and remote lighting conditions. The GloBug can be powered by a variety of Multiquip's series generators. Power requirements for running the GloBug are 120 VAC, 60 Hz @ 9.5 amps. The GloBug can be powered by any MQ portable generator with an output of 2.9 kW or greater.

Please read carefully the specified generator manual that will accompany your GloBug lighting system. This manual will explain how to operate and maintain the generator.

All information related to the generator will be referenced in a

NOTEseparate (supplied) "Operation and Parts Manual". Operation andmaintenanceofthegenerator will not be referenced in this manual.

The lighting system can be raised vertically in excess of 31.5 feet (9.6 meters) by means of a manual winch.The tower tensioning system is designed to provide the necessary tension to safely control the pivot of the tower.Outriggers must always be deployed prior to raising the mast.

DANGER - GloBug Overhead Obstructions

ALWAYS make sure the area above GloBug is open and clear of overhead power lines and other obstructions. The tower extends in excess of 16.5 ft. (5 meters). Contact with overhead powerlines or other obstructions could result in equipment

damage, Serious Injury or Death!

The lighting system of Multiquip's GloBug Lighting System is comprised of one "Metal Halide" 1000 watt lamp. This lamp has an output of 112,000 lumens. Typical lighting coverage is in excess 150 ft. (45.72 meters) in a 360 degree pattern.

Located underneath the generator support platform is a weather resistant ballast box that contains the ballast for starting the floodlight. The floodlight is activated by an ON/OFF switch located at the base of the mast.

For ease of service or transport, the floodlight is equipped with a quick-disconnect connector that allows the lamp fixture to be removed quickly.This feature is extremely useful during transport of the lighting system over rough terrain. It is always best to remove the floodlight and pack it safely so it will not be damaged.

Balloon Envelopes

The GloBug can be configured with a variety of balloon envelopes (canopy).Please contact the MQ sales department for the balloon of your choice.The GloBug, Model GB114BC comes with the standard balloon (BAL-120).

Alarm Buzzer

The GloBug is equipped with a "Balloon Alarm" feature.This alarm will sound if the lamp is on and the balloon attempts to make contact with the hot! surface of the lamp . This alarm is intended to inform the operator that a potential burn hazard exits between the lamp surface and the balloon material.

Always allow the lamp to cool down before removing the AC power from the GloBug. In the event the balloon begins to deflate during normal operation, immediately place the GloBug's ON/OFF switch in the OFF position.

PAGE 20 — GLOBUG LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #3 (03/22/06)

Image 20
Contents Model GB114BC Page Heres HOW to GET Help Table of Contents Direct TOLL-FREE access Globug Lighting System Safety Message Alert Symbols Foryour Safety and the Safety of OthersGlobug Lighting System Safety Message Alert Symbols General Safety Globug Lighting System Rules for Safe OperationMast Safety Globug Lighting System Rules for Safe OperationLamp Safety and Care Maintenance Safety EmergenciesGlobug Lighting System Operation and Safety Decals Machine Safety DecalsGlobug Lighting System Operation and Safety Decals Globug Lighting System Operation and Safety Decals Globug Lighting System Specifications SpecificationsGlobug Lighting System Dimensions Globug Lighting System Floodlight Footcandle Plot Floodlight Footcandle Plot Bal120-StandardGlobug Lighting System Floodlight Footcandle Plot Floodlight Footcandle Plot BAL120R-ReflectorDegree coverage Balloon Envelopes Alarm BuzzerGlobug Lighting System General Information Page Globug Lighting System Components Globug Lighting System Components GloBug Setup Outriggers Deployed PositionGlobug Lighting System PRE-SETUP Positioning the BalloonShutdown Globug Lighting System PRE-SETUP/OPERATIONApplying Power Globug Lighting System Shutdown StorageRemoving the Lamp Globug Lighting System MaintenanceRemoving the Lamp/Balloon Assembly Replacing the Balloon Globug Lighting System MaintenanceInstalling a New Lamp Removing the Lamp/Balloon Assembly Removal of WinchRemoving the Lamp Cable Check Cable WearCable Release Access Point Pulling-Out the Mast SectionsInstallation of Winch Cable Bypassing Cable Stop LatchInstallation of Winch Installing the HangerInstalling the Lamp Power Cable Ballast Box RemovalFilter Replacement Balloon/Lamp PlacementGlobug Lighting System Maintenance Wiring Diagram Wiring DiagramGlobug Lighting System Maintenance Globug Lighting System Maintenance Globug Lighting System -TROUBLESHOOTING Lamps Lamp TroubleshootingGlobug Lighting System -TROUBLESHOOTING Mast Mast TroubleshootingItems Found In the Items Number Column Explanation of Code in Remarks ColumnItems Found In the Remarks Column Globug Lighting System Spare Parts Qty DescriptionGlobug Lighting System Nameplate and Decals Globug Lighting System Nameplate and Decals Globug Lighting System -T-HANDLE Assy Handle Grip Globug Lighting System Steering Assy Part Name Globug Lighting System Outrigger Assy Bracket OUT,R R Globug Lighting System Mast Adapter Assy Stand Globug Lighting System Main Mast Assy Screw and Washer Globug Lighting System Mast Section Assy Second Mast Globug Lighting System Baseplate Cover Assy Cover Ballast CP Globug Lighting System Ballast Assy Holder Globug Lighting System FAN BLOWER/LAMP Base Assy Cable 2 Balloon CP Globug Lighting System BALLOON/LAMP Guard Assy Globug Lighting System BALLOON/LAMP Guard Assy Effective October 1, 2002 Terms and Conditions of Sale Parts Page Your Local Dealer is