Multiquip GB114BC manual Globug Lighting System -TROUBLESHOOTING Lamps, Lamp Troubleshooting

Page 38

GLOBUG LIGHTING SYSTEM —TROUBLESHOOTING (LAMPS)

Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, please take a remedial action following the diagnosis based on the Lamp Troubleshooting (Table 4) information shown below.

If the problem cannot be remedied, please leave the unit just as it is and consult or company's service department.

TABLE 4. LAMP TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

Is plug securely connected?

Plug in correctly.

 

 

 

 

Are generator and light tower switched on?

Turn on switch.

 

 

 

 

Is lamp loose?

Screw lamp securely into socket.

 

 

 

 

Is contactor properly connected?

Connect disconnected contactor.

 

 

 

 

Are any other electric appliances (other

 

Lamp does not light.

than light tower) plugged into power

Unplug all other appliances.

source?

 

 

 

 

 

 

 

Is generator voltage normal (non-load

Repair or replace generator.

 

voltage - 120 VAC)?

 

 

 

 

 

 

Is model of lamp compatible?

Use genuine MQ lamp.

 

 

 

 

Is lamp cool enough to light again?

 

 

(Interval of 20 to 30 minutes is required

Wait for lamp to cool down.

 

before turning on lamp again)

 

 

 

 

 

Is generator voltage normal (non-load

Repair or replace generator.

Lamp only lights for a

voltage - 120 V)?

 

short time.

Is ambient temperature too high (more than

Move lamp where there is proper

 

 

104 °F (40 °C)?

ventilation.

 

 

 

Balloon does not

Is fan motor (blower) working properly?

Check or repair fan motor (blower).

 

 

inflate.

Is balloon envelope defective?

Repair or replace balloon envelope.

 

 

 

 

PAGE 38 — GLOBUG LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #3 (03/22/06)

Image 38
Contents Model GB114BC Page Heres HOW to GET Help Table of Contents Direct TOLL-FREE access Globug Lighting System Safety Message Alert Symbols Foryour Safety and the Safety of OthersGlobug Lighting System Safety Message Alert Symbols General Safety Globug Lighting System Rules for Safe OperationMast Safety Globug Lighting System Rules for Safe OperationLamp Safety and Care Maintenance Safety EmergenciesGlobug Lighting System Operation and Safety Decals Machine Safety DecalsGlobug Lighting System Operation and Safety Decals Globug Lighting System Operation and Safety Decals Globug Lighting System Specifications SpecificationsGlobug Lighting System Dimensions Globug Lighting System Floodlight Footcandle Plot Floodlight Footcandle Plot Bal120-StandardGlobug Lighting System Floodlight Footcandle Plot Floodlight Footcandle Plot BAL120R-ReflectorDegree coverage Balloon Envelopes Alarm BuzzerGlobug Lighting System General Information Page Globug Lighting System Components Globug Lighting System Components GloBug Setup Outriggers Deployed PositionGlobug Lighting System PRE-SETUP Positioning the BalloonShutdown Globug Lighting System PRE-SETUP/OPERATIONApplying Power Globug Lighting System Shutdown StorageRemoving the Lamp Globug Lighting System MaintenanceRemoving the Lamp/Balloon Assembly Replacing the Balloon Globug Lighting System MaintenanceInstalling a New Lamp Removing the Lamp Cable Removing the Lamp/Balloon AssemblyRemoval of Winch Check Cable WearCable Release Access Point Pulling-Out the Mast SectionsInstallation of Winch Cable Bypassing Cable Stop LatchInstalling the Lamp Power Cable Installation of WinchInstalling the Hanger Ballast Box RemovalFilter Replacement Balloon/Lamp PlacementGlobug Lighting System Maintenance Wiring Diagram Wiring DiagramGlobug Lighting System Maintenance Globug Lighting System Maintenance Globug Lighting System -TROUBLESHOOTING Lamps Lamp TroubleshootingGlobug Lighting System -TROUBLESHOOTING Mast Mast TroubleshootingItems Found In the Items Number Column Explanation of Code in Remarks ColumnItems Found In the Remarks Column Globug Lighting System Spare Parts Qty DescriptionGlobug Lighting System Nameplate and Decals Globug Lighting System Nameplate and Decals Globug Lighting System -T-HANDLE Assy Handle Grip Globug Lighting System Steering Assy Part Name Globug Lighting System Outrigger Assy Bracket OUT,R R Globug Lighting System Mast Adapter Assy Stand Globug Lighting System Main Mast Assy Screw and Washer Globug Lighting System Mast Section Assy Second Mast Globug Lighting System Baseplate Cover Assy Cover Ballast CP Globug Lighting System Ballast Assy Holder Globug Lighting System FAN BLOWER/LAMP Base Assy Cable 2 Balloon CP Globug Lighting System BALLOON/LAMP Guard Assy Globug Lighting System BALLOON/LAMP Guard Assy Effective October 1, 2002 Terms and Conditions of Sale Parts Page Your Local Dealer is