GLOBUG LIGHTING SYSTEM — MAINTENANCE

For a prolonged life cycle an extended quality follow the recommended GloBug service guidelines as referenced in Table 3.

TABLE 3. PERIODIC CHECK AND MAINTENANCE

FIGURE

PART

 

 

CHECK ITEM

SOLUTION

 

 

 

 

 

 

 

 

 

L1

Frame Pipe

 

Frame pipe skewed?

Replace.

 

 

 

 

 

 

 

 

L2

Lamp Holder

 

Lamp holder loose?

Tighten or replace.

Lamp

 

 

 

 

 

 

L3

Lamp (Base)

 

Lamp base loose?

Screw in securely.

 

 

 

 

 

 

 

 

L4

Lamp

 

Defective lamp?

Replace.

 

 

 

 

 

 

 

L5

Cable/Connector

Cable disconnected or loose?

Connect securely.

 

 

 

 

 

 

 

B1

Balloon (Envelope)

Defective or dirty?

Replace.

 

 

 

 

 

 

 

 

Balloon

B2

Zipper

 

Broken?

 

Replace.

 

 

 

 

 

 

 

B3

Fan Motor (Blower)

Working properly?

Repair or replace.

 

 

 

 

 

 

 

M1

Mast Sliding Surface

Slides smoothly?

Apply grease.

 

 

 

 

 

 

 

 

 

M2

Wire Rope

 

Damaged?

 

Apply grease or replace.

 

 

 

 

 

 

Mast

M3

Wire Rope End

Is wire end damaged (caulking)?

Replace.

 

 

 

 

 

 

 

 

M4

Winch

 

Defective winch brake ?

Repair or replace.

 

 

 

 

 

 

 

 

M5

Safety Stop

 

Safety latch defective?

Repair or replace.

 

 

 

 

 

 

 

C1

Counter-Weight

Travels smoothly?

Spray grease.

 

 

 

 

 

 

 

 

C2

Outriggers

 

Travels smoothly?

Spray grease.

 

 

 

 

 

 

 

C3

T-handle and Wheels

Proper movement.

Tighten securely.

 

 

 

 

 

 

 

C4

Bolt for Handle

Check if bolt is not loose.

Tighten securely.

 

 

 

 

 

 

 

 

C5

Brake Pedal

 

Linkage working correctly.

Check, spray grease

 

 

 

 

 

 

 

Cart

C5

Brake Pedal

 

Notch worn-out?

Replace.

 

 

 

 

 

 

 

 

C6

Hanger

 

Check if the installation is not loose.

Fasten securely.

 

 

 

 

 

 

 

C7

Front Wheel Pivot

Turns smoothly?

Check, apply grease.

 

 

 

 

 

 

 

 

C8

Tires

 

Tire pressure 35.5 psi (294 kPa)?

Adjust.

 

 

 

 

 

 

 

C9

Link for Front Shaft

Linkage moves smoothly?

Spray grease.

 

 

 

 

 

 

 

 

C10

Brake

 

Working properly?

Adjust.

 

 

 

 

 

 

 

Electric

E1

Power Cable

 

Defective or worn cable?

Replace.

 

 

 

 

 

 

 

E2

Non-load Voltage

Is generator output 125 VAC?

Adjust or replace generator.

 

 

 

 

 

 

 

 

 

 

- Daily Check

- Every 20 Hours

- Every 100 hours

- Every 500 hours

 

GLOBUG LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #3 (03/22/06) — PAGE 37

Image 37
Contents Model GB114BC Page Heres HOW to GET Help Table of Contents Direct TOLL-FREE access Foryour Safety and the Safety of Others Globug Lighting System Safety Message Alert SymbolsGlobug Lighting System Safety Message Alert Symbols Globug Lighting System Rules for Safe Operation General SafetyGlobug Lighting System Rules for Safe Operation Mast SafetyLamp Safety and Care Emergencies Maintenance SafetyMachine Safety Decals Globug Lighting System Operation and Safety DecalsGlobug Lighting System Operation and Safety Decals Globug Lighting System Operation and Safety Decals Specifications Globug Lighting System SpecificationsGlobug Lighting System Dimensions Floodlight Footcandle Plot Bal120-Standard Globug Lighting System Floodlight Footcandle PlotFloodlight Footcandle Plot BAL120R-Reflector Globug Lighting System Floodlight Footcandle PlotDegree coverage Globug Lighting System General Information Alarm BuzzerBalloon Envelopes Page Globug Lighting System Components Globug Lighting System Components Outriggers Deployed Position GloBug SetupPositioning the Balloon Globug Lighting System PRE-SETUPApplying Power Globug Lighting System PRE-SETUP/OPERATIONShutdown Storage Globug Lighting System ShutdownRemoving the Lamp/Balloon Assembly Globug Lighting System MaintenanceRemoving the Lamp Installing a New Lamp Globug Lighting System MaintenanceReplacing the Balloon Removal of Winch Removing the Lamp/Balloon AssemblyRemoving the Lamp Cable Check Cable WearPulling-Out the Mast Sections Cable Release Access PointBypassing Cable Stop Latch Installation of Winch CableInstalling the Hanger Installation of WinchInstalling the Lamp Power Cable Ballast Box RemovalBalloon/Lamp Placement Filter ReplacementWiring Diagram Globug Lighting System Maintenance Wiring DiagramGlobug Lighting System Maintenance Globug Lighting System Maintenance Lamp Troubleshooting Globug Lighting System -TROUBLESHOOTING LampsMast Troubleshooting Globug Lighting System -TROUBLESHOOTING MastItems Found In the Remarks Column Explanation of Code in Remarks ColumnItems Found In the Items Number Column Qty Description Globug Lighting System Spare PartsGlobug Lighting System Nameplate and Decals Globug Lighting System Nameplate and Decals Globug Lighting System -T-HANDLE Assy Handle Grip Globug Lighting System Steering Assy Part Name Globug Lighting System Outrigger Assy Bracket OUT,R R Globug Lighting System Mast Adapter Assy Stand Globug Lighting System Main Mast Assy Screw and Washer Globug Lighting System Mast Section Assy Second Mast Globug Lighting System Baseplate Cover Assy Cover Ballast CP Globug Lighting System Ballast Assy Holder Globug Lighting System FAN BLOWER/LAMP Base Assy Cable 2 Balloon CP Globug Lighting System BALLOON/LAMP Guard Assy Globug Lighting System BALLOON/LAMP Guard Assy Effective October 1, 2002 Terms and Conditions of Sale Parts Page Your Local Dealer is