Multiquip DCA40SSKU4i manual General saFeTY, GeneraTor saFeTY

Page 7

Safety Information

general saFeTY

CaUTion

„never operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations.

„ never operate this equipment when not feeling well due to fatigue, illness or when under medication.

„never operate this equipment under the infl uence of drugs or alcohol.

„alWaYs check the equipment for loosened threads or bolts before starting.

„Do noT use the equipment for any purpose other than its intended purposes or applications.

NOTICE

„This equipment should only be operated by trained and qualifi ed personnel 18 years of age and older.

„Whenever necessary, replace nameplate, operation and safety decals when they become diffi cult read.

„Manufacturer does not assume responsibility for any accident due to equipment modifi cations. Unauthorized equipment modifi cation will void all warranties.

„never use accessories or attachments that are not recommended by MQ Power for this equipment. Damage to the equipment and/or injury to user may result.

„ alWaYs know the location of the nearest fire extinguisher.

„ alWaYs know the location of the nearest first aid kit.

„alWaYs know the location of the nearest

phone or keep a phone on the job site. Also, know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

generaTor saFeTY

Danger

„never operate the equipment in an explosive atmosphere or near combustible materials.An explosion or fi re could result causing severe bodily harm or even death.

Warning

„never disconnect any emergency or safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.

CaUTion

„never lubricate components or attempt service on a running machine.

NOTICE

„alWaYs ensure generator is on level ground before use.

„alWaYs keep the machine in proper running condition.

„Fix damage to machine and replace any broken parts immediately.

„alWaYs store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel

DCA40sskU/ku4i 60 hz Generator • operation and parts manual — rev. #1 (03/11/13) — page 7

Image 7
Contents Model DCA40SSKU Model DCA40SSKU4i Proposition 65 warning Administrator Reporting Safety DefectsDCA45SSKU/SSKU4i 60 Hz Generator Table of ContentsChoose from three easy options SaFeTY messages Safety InformationGeneraTor saFeTY General saFeTYRestricted. If the air fl ow is Engine saFeTYIf operating in speed ranges above the maximum allowable From fuel vapors or if fuel is spilled on a hot engine FUel saFeTYToWing saFeTY „ never use fuel as a cleaning agentGrounding safety EleCTriCal saFeTYPower Cord/Cable safety EnvironmenTal saFeTY BaTTerY saFeTY240/120 SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationGenerator Grounding Outdoor InstallationIndoor Installation MountingGeneral Information Item no Major ComponentsEngine Control Panel Will remain OFF. When the ignitionGenerator Control Panel Generator control PanelTerminal legs O and Ground are considered bonded grounds Output Terminal FamiliarizationOutput Terminal Panel is provided with the following VAC Gfci Receptacles Removing the Plastic Face Plate Hard Wire Hookup PanelOver Current Relay Connecting LoadsThree Phase Load Single Phase LoadLoad Application Generator Amperage Voltage Selector SwitchVoltage Selector Switch Locking Button Generator Output VoltagesAC Ammeter Gauge Reading How to Read the ac ammeter and ac voltage gaugesGenerator OUTPUTS/gauge reading AC Voltmeter Gauge Reading3Ø-240/139 Uvwo Terminal Output Voltages Uvwo Terminal Output Voltages3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages 1Ø-240/120V Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output VoltagesFuel Check Inspection/SETUPCircuit Breakers Lubrication OilRemove fuel cap and fill tank as shown in Figure Refueling ProcedureOperation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt Tension Coolant Antifreeze/Summer Coolant/ WaterAlternator BatteryBattery Cable Installation WiringStarting Before StartingEngine’s exhaust contains harmful emissions Place the engine speed control switch in the RUN position up Emergency Shutdown Procedure Normal Shutdown ProcedureAutomatic Shut-down System General Inspection Air Cleaner MaintenanceAir Cleaner with Dust Indicator Fuel Tank Inspection Cleaning Inside the Fuel TankFuel Addition Removing Water from the Fuel TankReplacing Oil Filter Radiator CleaningAir Removal Check Oil LevelBattery Charger and Jacket Water Heater option JacketWater Heater and Internal Battery OptionalTrailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Actuator Brake AdjustmentBrakes Hydraulic Surge BrakesTire Wear/Inflation Tires/Wheels/Lug NutsSuspension Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramGenerator Troubleshooting Troubleshooting GeneratorPage Explanation of Code in Remarks Column To 3 units Suggested Spare PartsGenerator Assy B3120100804 B31100013020601820083 0601822664Control box Assy Y0330000190 M1213002012Y0330000555 Y0330000255Control box Assy 0601840073 06018068590601808986 AC AMMETER, 0~75/150A5A 0601807641 0601801040Engine and Radiator Assy HH1C032430 M19232001641G54197010 1663143560Engine and Radiator Assy M1310201004 01936013000605515170 M1310200904Output Terminal Assy 0041410000 81118603030801831704A 0039310000Battery Assy 0602220920 0602220199M9310500014 M9103000304Muffler Assy 0030410000 M1330101403M1333003503 Y0602320157Fuel Tank Assy 0605516090 M13630026020605505070 0605501072Enclosure Assy M1493110203 M1413004202M1413400004 M1423003102Enclosure Assy M1453006213 001910805536A 0042308000 36B 031108160Rubber Seals Assy 0229400970 Y0228901240Y0228900625 Y0228900595Nameplate and Decals Assy M9500400204 M9522000504M9520000104 M9522000604FreighT poliCY Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help