Multiquip operation manual DCA-25SSIU2 60 HZ-TRAILER Maintenance, Brakes, Brake Adjustment

Page 41

DCA-25SSIU2 (60 HZ)—TRAILER MAINTENANCE

Brakes

Trailer brakes should be inspected the first 200 miles of operation. This will allow the brake shoes and drums to seat properly. After the first 200 mile interval, inspect the brakes every 3,000 miles. If driving over rough terrain, inspect the brakes more frequently.

Figure 57 displays the major hydraulic surge brake components that will require inspection and maintenance. Please inspect these components as required using steps 1 through 8 and Table 15 as shown below:

Brake Adjustment

1.Place the trailer on jack stands. Make sure the jack stands are placed on secure level ground.

2.Check the wheel and drum for free rotation.

3.Remove the adjusting hole cover from the adjusting slot at the bottom brake backing plate.

4.With a screwdriver or standard adjusting tool, rotate the star wheel of the adjuster assembly to expand the brake shoes.

5.Adjust the brake shoes outward until the pressure of the lining against the wheel drum makes the wheel difficult to turn.

6.Adjust, rotate the star wheel in the opposite direction until the wheel rotates freely with slight lining drag.

7.Replace the adjusting hole cover and lower the trailer to the ground.

8.Repeat steps 1 through 7 on the remaining brakes.

Hydraulic Surge Brakes

Hydraulic surge brakes (Figure 56) should not require any special attention with the exception of routine maintenance such as shoe and lining replacement. Brake lines should be periodically checked for cracks, kinks, or blockage.

Figure 57. Hydraulic Brake Components

Actuator

Hydraulic surge braking requires the installation of an actuator at the tongue of the trailer. Remember the surge or push of the trailer toward the tow vehicle automatically synchronizes the trailer brakes with the tow vehicle brakes. As the trailer pushes against the tow vehicle the actuator telescopes together and applies force to the master cylinder, supplying hydraulic pressure to the trailer brakes.

Periodically check and test the surge “actuator” to make sure that it is functioning correctly. Never use an undersize actuator.

Table 15. Hydraulic Brake Troubleshooting

Symptom

Possible Cause

Solution

 

 

 

No Brakes

Brake line broken or kinked?

Repair or replace.

 

 

 

 

Brake lining glazed?

Reburnish or replace.

 

 

 

 

Trailer overloaded?

Correct weight.

Weak Brakes or Brakes Pull to

 

 

Brake drums scored or grooved?

Machine or replace.

One Side

 

 

 

Tire pressure correct?

Inflate all tires equally.

 

 

 

 

Tires unmatched on the same axle?

Match tires.

 

 

 

Locking Brakes

Brake components loose, bent or broken?

Replace components.

 

 

Brake drums out-of-round?

Replace.

 

 

 

 

Noisy Brakes

System lubricated?

Lubricate.

 

 

Brake components correct?

Replace and correct.

 

 

 

 

 

Brake lining thickness incorrect or not

Install new shoes and

Dragging Brakes

adjusted correctly?

linings.

 

 

Enough brake fluid or correct fluid?

Replace rubber parts

 

 

fill with dot 4 fluid.

 

 

 

 

 

DCA-25SSIU2 (60 HZ)— OPERATION AND PARTS MANUAL — REV. #0 (01/27/06) — PAGE 41

Image 41
Contents Model DCA-25SSIU2 Parts List NO. M1870300804Page Wilmington Ave Carson, CA Heres HOW to GET HelpTable of Contents When ordering parts Please supply the following information Parts Ordering ProceduresDCA-25SSIU2 60 HZ- Specifications Dimensions DCA-25SSIU2 60 HZ- Dimensions TOP, Side and FrontHas been developed to provide DCA-25SSIU2 60 HZ Safety Message Alert SymbolsThis generator, other property, or DCA-25SSIU2 60 HZ Safety Message Alert SymbolsBurns General SafetyDCA-25SSIU2 60 HZ- Rules for Safe Operation Generator Grounding Electrical SafetyDCA-25SSIU2 60 HZ- Rules for Safe Operation Battery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyGenerator Decals DCA-25SSIU2 60 HZ- Generator DecalsDCA-25SSIU2 60 HZ- Generator Decals DCA-25SSIU2 60 HZ- Installation Outdoor Installation DCA-25SSIU2 60 HZ- InstallationIndoor Installation When connecting the generatorDCA-25SSIU2 60 HZ- General Information Generator Major Components DCA-25SSIU2 60 HZ- Major ComponentsDCA-25SSIU2 60 HZ- Generator Control Panel DCA-25SSIU2 60 HZ- Engine Operating Panel Output Terminal Familiarization DCA-25SSIU2 60 HZ- Output Terminal Panel FamiliarizationF.C.I. Receptacle 120VAC Gfci Receptacles DCA-25SSIU2 60 HZ- Output Terminal Panel FamiliarizationBlower Fan Connecting LoadsThree Phase Load Single Phase LoadDCA-25SSIU2 60 HZ- Load Application Motors and motor-drivenDCA-25SSIU2 60 HZ- Generator Outputs Voltage Selector SwitchGenerator OutputVoltages Generator AmperageReading Amperage How to Read the OutputTerminal GaugesDCA-25SSIU2 60 HZ- Gauge Reading DCA-25SSIU2 60 HZ- Output Terminal Panel Connections Three-Phase PositionUvwo Terminal Output Voltages 3Ø-240/139 Output Terminal Lug Voltages1Ø 240V/120V Output Terminal Lug Voltages DCA-25SSIU2 60 HZ- Output Terminal Panel Connections3Ø 480/277 Output Terminal Lug Voltages Circuit Breakers DCA-25SSIU2 60 HZ- PRE-SETUPLubrication Oil Fuel CheckRefueling DCA-25SSIU2 60 HZ- PRE-SETUPRefueling Procedure Air Cleaner Fan Belt Tension Cleaning the RadiatorOperation FreezingWeather Vol % Freezing PointBattery Cable Installation BatteryWhen connecting battery do the following WiringBefore Starting DCA-25SSIU2 60 HZ- Generator START-UP ProcedureEngines exhaust contains harmful emissions Direct exhaust away from nearby personnelFrequency Meter Hz Remove all loads from the generator DCA-25SSIU2 60 HZ- GEN. START-UP PROCEDURE/SHUTDOWNTurn the ignition switch key to the Stop position DCA-25SSIU2 60 HZ- Maintenance Air Removal Cleaning the Fuel StrainerCheck Oil Level Replacing Oil FilterTo ensure adequate starting DCA-25SSIU2 60 HZ- MaintenanceTrailer Maintenance DCA-25SSIU2 60 HZ-TRAILER MaintenanceBrake Adjustment DCA-25SSIU2 60 HZ-TRAILER MaintenanceBrakes Check the wheel and drum for free rotationSuspension Tires/Wheels/Lug NutsTire Wear/Inflation Start all wheel lug nuts by hand DCA-25SSIU2 60 HZ-TRAILER MaintenanceLug Nut Torque Requirements DCA-25SSIU2 60 HZ-TRAILERWIRING Diagram Generator Wiring Diagram DCA-25SSIU2 60 HZ- Generatorwiring DiagramDCA-25SSIU2 60 HZ- Enginewiring Diagram Generator Troubleshooting DCA-25SSIU2 60 HZ-TROUBLESHOOTING GeneratorStarter does not run DCA-25SSIU2 60 HZ-TROUBLESHOOTING EngineEngine does not start DCA-25SSIU2 60 HZ-TROUBLESHOOTING Engine If more than one of the same Explanation of Code in Remarks ColumnItems Found In the Items Number Column DCA-25SSIU2 60 HZ- Suggested Spare Parts Part number on this Suggested Spare Parts listDCA-25SSIU2 60 HZ- Generator Assy 7961025004 B11102006020601822630 8001070003DCA-25SSIU2 60 HZ- Control BOX Assy 0601870430 M12130009020021004075 0601842384Control BOX ASSY.CONT 0601806859 0601808985 AC AMMETER, ACF-6 0~50A/100A5A 06018010400601801041 0601840073DCA-25SSIU2 60 HZ- Engine Operating Panel Assy 8944024980 89704441800602103092 2A# 0601810245 BULB, E-10 T-10 DC18V 0602120095DCA-25SSIU2 60 HZ- Engine & Radiator Assy 0602041210 M1923200044M1305200304 M1305200204DCA-25SSIU2 60 HZ- Engine & Radiator ASSY. 0603306590 06020225610603300285 0605511395 VALVE, XV500P-8 0603306395 Hose Joint 0602021070Output Terminal Assy DCA-25SSIU2 60 HZ- Outputterminal AssyM9220000004 M1230700003M9220000104 0039308000DCA-25SSIU2 60 HZ- Battery Assy M9310500014 0602220185M9103000304 0602220920DCA-25SSIU2 60 HZ- Muffler Assy M1333201703 06023003908970420280 M1333200014DCA-25SSIU2 60 HZ- Fuel Tank Assy DCA-25SSIU2 60 HZ- Fueltank Assy Enclosure Assy DCA-25SSIU2 60 HZ- Enclosure AssyM1413400004 M1413002802M1423001802 M1493104903Enclosure ASSY.CONT DCA-25SSIU2 60 HZ- Enclosure ASSY.M1453003803 001690805533A M1493405604 M1453003903DCA-25SSIU2 60 HZ- Rubber Seals Assy 0228900695 02289011700228900725 M1490300004DCA-25SSIU2 60 HZ- Nameplate and Decals M1550000204 M1550000104M1550001603 M1550017003Freightpolicy Terms and Conditions of Sale PartsPage Your Local Dealer is
Related manuals
Manual 82 pages 62.92 Kb

DCA-25SSIU2 specifications

The Multiquip DCA-25SSIU2 is a versatile and powerful diesel generator, designed to meet the needs of various industries while providing a reliable source of power. This model is particularly popular in construction, event management, and emergency backup supply applications. With its robust build and advanced features, the DCA-25SSIU2 stands out as a top choice for professionals seeking durability and efficiency.

One of the significant features of the DCA-25SSIU2 is its impressive power output. The generator delivers a continuous output of 25 kVA, making it suitable for powering heavy machinery, tools, and equipment. This model is equipped with a turbocharged, liquid-cooled YANMAR engine, known for its performance and fuel efficiency. The engine operates quietly, ensuring minimal noise pollution in sensitive environments.

Built to withstand harsh conditions, the DCA-25SSIU2 is housed in a sturdy steel frame enclosure. The design not only protects the generator from the elements but also reduces noise levels. The enclosure features a weather-resistant finish, making it ideal for both indoor and outdoor applications. Additionally, the unit's compact size allows for easy transportation and storage, which is an essential consideration for contractors on the go.

The DCA-25SSIU2 incorporates advanced technology to enhance performance and user experience. It features a digital control panel, offering intuitive monitoring of generator status, fuel consumption, and operational hours. Automatic voltage regulation ensures a stable output, protecting connected devices from voltage fluctuations.

Fuel efficiency is another highlight of this generator. The DCA-25SSIU2 operates on diesel, which is not only readily available but also provides a longer run time compared to gasoline generators. The large fuel tank capacity allows for extended periods of operation without frequent refueling.

Safety is a critical aspect of the DCA-25SSIU2. The generator is equipped with safety features such as low oil shut-off, overload protection, and a heavy-duty frame for stability. These elements ensure that the generator operates safely and reliably, even in demanding situations.

In conclusion, the Multiquip DCA-25SSIU2 diesel generator combines power, efficiency, and ruggedness. Its blend of advanced features, fuel efficiency, and safety make it an excellent choice for a wide range of applications. Whether for construction projects, outdoor events, or emergency power needs, the DCA-25SSIU2 stands as a testament to Multiquip's commitment to quality and innovation in the generator market.