Generac Power Systems 009600-5, 009734-5 owner manual Specifications, Fuel Consumption gph/lbs.ph

Page 8

Section 1 – General Information

PRIMEPACT 66G and 66LP Recreational Vehicle Generators

Figure 1.1 – Connection for 120 Volts Only

Figure 1.2 - Connection for 120/240 Volts

Fuel Consumption (gph/lbs.ph)

 

Model

No Load

1/2 Load

Full Load

 

 

PrimePact 66G

0.33

0.59

0.99

 

 

PrimePact 66LP

0.47/2.01

0.85/3.62

1.66/7.05

 

NOTE

Some installations using a “shared” fuel tank may have a generator fuel pickup tube that is shorter than the vehicle engine’s pickup tube. Such an arrangement causes the generator engine to “run out of gas” while adequate fuel for the vehicle remains in the tank.

To reduce lead and carbon deposits use high quality UNLEADED gasoline with the generator. Leaded REGULAR grade gasoline is an acceptable substitute.

NOTE:

Using unleaded gasoline contributes to longer engine valve life by reducing lead and carbon deposits.

CB1

T1

RED

T2

Generac does not recommend using any gasoline containing alcohol (such as “gasohol”). If you use any gasoline containing alcohol, it must not contain more than 10 percent ethanol,

WHITE

CB2T3

BLACK

STATOR WINDINGS GROUNDED NEUTRAL

1.6SPECIFICATIONS

1.6.1 FUEL REQUIREMENTS

This generator is equipped with a gasoline fuel system as standard equipment. Specific installations may pro- vide either a separate fuel tank for the generator, or the generator may “share” the vehicle engine’s fuel tank.

and it must be removed from the generator during storage. Do NOT use any gasoline containing methanol. If you use gasoline with alcohol, inspect more frequently for fuel leaks and other abnormalities.

1.6.2 ENGINE OIL REQUIREMENTS

Use only high quality detergent oil classified “For Service SF” and with an oil viscosity rating of SAE 10W-30 oil. Do not pour in any additives to the rec- ommended oil. Engine crankcase capacity is 1.4 liters. See Section 3.2 on page 11 for oil level check and filing procedures.

 

 

1.6.3

GENERATOR SPECIFICATIONS

 

 

 

SERIES

 

PRIMEPACT 66G

 

PRIMEPACT 66LP

 

 

Rotor RPM

 

3600

 

3600

 

 

Rotor Poles

 

2

 

2

 

 

Engine RPM

 

2700

 

2700

 

 

Rated Max. Continuous AC Output*

 

6600 watts (6.6 kW)

 

6200 watts (6.2 kW)

 

 

Voltage*

 

120

 

120

 

 

Rated Max. Continuous Current*

 

55.0 AC amps‡

 

51.7 AC amps Ñ

 

 

Phase

 

1

 

1

 

 

Frequency

 

60 Hertz

 

60 Hertz

 

 

Battery Charging Current (Max.)

 

2 amps (trickle charge)

 

2 amps (trickle charge)

 

 

Weight

 

213 pounds

 

216 pounds

 

 

Length

 

25 inches

 

25.75 inches

 

 

Width

 

18.5 inches

 

18.5 inches

 

 

Height

 

15.75 inches

 

15.75 inches

 

 

 

 

 

 

 

 

*All units are reconnectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVIA/ANSI when reconnected for dual voltage output

‡ Rated maximum continuous current at 240 volts is 27.5 amps. Ñ Rated maximum continuous current at 240 volts is 25.8 amps.

6 Generac® Power Systems, Inc.

Image 8
Contents Power SYSTEMS, INC Authorized Service Dealer Location IntroductionTable of Contents General Hazards Electrical Hazards Generator Identification Reference Number IdentificationInstallation SafetyGenerator Applicability Generator AC Connection SystemSpecifications Fuel Consumption gph/lbs.phFuel Requirements Engine OIL RequirementsGenerator Control Panel Before Starting the Engine Optional Remote START/STOP PanelAutomatic Choke Stopping the Generator Starting the GeneratorEngine Exhaust GAS Letting the Engine StabilizeHigh Temperature Switch LOW OIL Pressure SwitchProtection Systems Field BoostChecking the Engine OIL Level Overvoltage Protection6 25-HOUR CHECK-UP 5 25-HOUR BREAK-IN PeriodChanging the Engine OIL AND/OR OIL Filter Maintaining the Engine AIR CleanerCleaning the Foam Precleaner Spark Arrestor Muffler Clean AIR Intake ScreenChecking the Engine Spark Plug Cleaning the Generator Battery MaintenanceWeekly Every SIX MonthsOUT of Service Procedure Drive BeltExercising the Generator Wattage Reference GuidePrimepact 66G and 66LP Recreational Vehicle Generators Part General Hazards Electrical Hazards Purpose and Scope Installation Instructions Standards BookletsEquipment Description Generator Engine Operating SpeedMajor Features and Dimensions Location and Support Generator SupportGenerator Location Suspended MountingGenerator Compartments Generator RestraintCompartment Construction Compartment SizeSound Insulating Materials AcousticsCompartment Floor Cutout Cooling and Ventilating AIR Compartment Floor CutoutsCooling AIR Inlet Openings Generator AirflowCompensating for Restrictions Testing the InstallationGasoline Fuel System Parts not Included in Fuel System LP GAS Fuel SystemGenerator Fuel Supply Line Primary Regulator Some Important ConsiderationsVapor Withdrawal Gaseous CarburetionExhaust System Fuel Supply LinesExcess Flow Valve Leakage TestsExhaust System Safety WiringElectrical Connections Type of Exhaust SystemBattery Installation Battery Cables 18 Transfer Switch Isolation MethodOptional Accessories Battery Cable ConnectionsBattery Compartment Remote Panel ModelsPost Installation Tests Testing Under LoadBefore Initial START-UP Initial StartInstallation Checklist Troubleshooting Guide Problem Cause CorrectionGenerac Power Systems, Inc Electrical Data Exploded Views and Parts Lists QTY Description To Engine BASE, Mounting To Engine BASE, Mounting To Engine Ground Item Part NO. QTY. Description Exploded Views and Parts Lists QTY Description Exploded Views and Parts Lists Carburetor Assemby CARB. V-TWIN L/P Primepact 66G and 66LP Recreational Vehicle Generators Primepact 66G and 66LP Recreational Vehicle Generators Primepact 66G and 66LP Recreational Vehicle Generators PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Control System Warranty Emission Related Parts Include the FollowingGenerac Power SYSTEMS, INC