DOCUMENT 1025
REV. B
Instruction Manual
AGS-LED
858 LED Series
Sizes 1, 2, 3, 4 and 5
d.The concrete foundation/pad should be not more than 1 inch above grade in order too maintain the 3 inch maximum overall height a bove grade to the point of frangibility per FAA Engiineering Brief no.
79.See the Engineering Brief for acceptable grading around the foundation/pad. T he foundation/pad pad must be level.
e.It is recommended that the conttractor who is to install the concrete foundation/pad use cast in place anchor bolts. The threaded portiion of the anchor bolts should be
13.The clearance holes on the floor flange are 5/8 inch diameter on a 4.75 inch diammeter bolt circle for use with ½ inch anchor bolts.
f.The concrete foundation/pad should include the series isolation transformer housingg. It is recommended that this housing not be placed under the sign power leg to allow acccess to the series isolation transformer and conneections for ease of troubleshooting and servicing (Seee Figures 12, 12a- 12c). This housing would be on the side closest to the Taxiway or Runway. A 2 incch conduit elbow with threaded coupling attachedd at sign end would exit from the transformer housinng side to the foundation/pad and be flush witth the with the top of the concrete foundation/pad gr ade level centered between the floor flange bolts n earest the Taxiway or Runway side of the sign. Thee sign as viewed will have the circuit card box to the right on the “A” side of the sign, which is closest to the Taxiway or Runway side of the sign. If the location requires an additional housing to accommodate multiple messages, then the separation distance between these signs housings can be 3 inches minimum to 12 inches maximum (FAA AC
|
| DANGER: |
DANGER |
| Lock out eleectrical power to the series loop that will pow er the sign at |
| ||
|
| its source before attempting any electrical connections/spplices. |
|
|
|
g.Make electrical connections to the series loop power using
4