DOCUMENT 1025
REV. B
Instruction Manual
858 LED Series
Sizes 1, 2, 3, 4 and 5
L858 AGS
Output Current
Setting
Input voltage configuration
Output LED Configuration
Calibration
Mode/
Normal
Operation
Series CCR
Size #Mods
1 1
12
13
14
21
22
23
24
31
32
33
34
4 2
SW1-
4
x
x
x
x
x
x
x
x
x
x
x
x
ON
| 
 | SW1- | 
 | 
 | SW1- | 
 | 
 | SW2- | 
 | 
 | SW2- | 
 | 
 | SW2- | 
 | 
 | SW2- | 
 | 
 | SW2- | 
 | 
 | SW2- | 
 | 
 | 
 | 
 | JP1 | 
 | 
 | JP2 | 
 | |
| 
 | 5 | 
 | 
 | 6 | 
 | 
 | 1 | 
 | 
 | 2 | 
 | 
 | 3 | 
 | 
 | 4 | 
 | 
 | 5 | 
 | 
 | 6 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | ON | 
 | OFF | 
 | ON | 
 | ON | 
 | ON | 
 | ON | 
 | ON | 
 | ON | 
 | ON/OFF | 
 | Close | 
 | Close | |||||||||||
| 
 | ON | 
 | OFF | 
 | ON | 
 | ON | 
 | ON | 
 | ON | 
 | ON | 
 | OFF | 
 | ON/OFF | 
 | Close | 
 | Close | |||||||||||
| 
 | ON | 
 | OFF | 
 | ON | 
 | ON | 
 | ON | 
 | ON | 
 | OFF | 
 | ON | 
 | ON/OFF | 
 | Close | 
 | Close | |||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | ON | 
 | OFF | 
 | ON | 
 | OFF | 
 | ON | 
 | ON | 
 | OFF | 
 | OFF | 
 | ON/OFF | 
 | Close | 
 | Open | |||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | x | 
 | ON | 
 | ON | 
 | ON | 
 | ON | 
 | OFF | 
 | ON | 
 | ON | 
 | ON/OFF | 
 | Close | 
 | Close | |||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | x | 
 | ON | 
 | ON | 
 | ON | 
 | ON | 
 | OFF | 
 | ON | 
 | OFF | 
 | ON/OFF | 
 | Close | 
 | Close | |||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | x | 
 | ON | 
 | ON | 
 | OFF | 
 | ON | 
 | OFF | 
 | OFF | 
 | ON | 
 | ON/OFF | 
 | Close | 
 | Open | |||||||||||
| 
 | x | 
 | ON | 
 | OFF | 
 | OFF | 
 | ON | 
 | OFF | 
 | OFF | 
 | OFF | 
 | ON/OFF | 
 | Open | 
 | Open | |||||||||||
| 
 | ON | 
 | OFF | 
 | ON | 
 | ON | 
 | OFF | 
 | ON | 
 | ON | 
 | ON | 
 | ON/OFF | 
 | Close | 
 | Close | |||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | ON | 
 | OFF | 
 | ON | 
 | OFF | 
 | OFF | 
 | ON | 
 | ON | 
 | OFF | 
 | ON/OFF | 
 | Close | 
 | Open | |||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | ON | 
 | OFF | 
 | OFF | 
 | OFF | 
 | OFF | 
 | ON | 
 | OFF | 
 | ON | 
 | ON/OFF | 
 | Open | 
 | Open | |||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||||||||||||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | ON | 
 | OFF | 
 | OFF | 
 | OFF | 
 | OFF | 
 | ON | 
 | OFF | 
 | OFF | 
 | ON/OFF | 
 | Open | 
 | Open | |||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | OFF | 
 | OFF | 
 | ON | 
 | OFF | 
 | OFF | 
 | OFF | 
 | ON | 
 | ON | 
 | ON/OFF | 
 | Close | 
 | Open | |||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
Table 2. Power Supply Switch and Jumper Selection (SERIES CCR)