Cooper Bussmann 858 Max. See F igure 18 Also, remover carriers from thermmal pad

Page 15

DOCUMENT 1025

REV. B

Instruction Manual

AGS-LED

858 LED Series

Sizes 1, 2, 3, 4 and 5

 

 

CAUTION:

CAUTION

 

Do not over tighten hex nut on stud retaining bridge recttifier. 8in-lbs

 

 

 

max. (See F igure 18) Also, remover carriers from thermmal pad

 

 

adhesive surfaces before installing.

 

 

 

WARNING:

IMPORTANT When tightening cover screws, do not use power drivers as you may exceed the maximum torque of 75 in-lbs on the cover sc rews.

 

 

DANGER:

DANGER

 

When replaacing parts inside the circuit box or sign housiing, lock out

 

 

 

series circuiit power at its source.

 

 

 

10.2Problem Solving Guide

 

PROBLEM

 

POSSIBLE CAUSE

CORRECTIVVE

ACTION

 

 

 

 

 

 

 

 

 

 

(P.1) Sign will

No inpput current. (LEDs on Power

Measure input cuurrent

 

 

not light

Supplyy board not lit)

according to Secctions 10.3 and

 

 

 

 

 

 

10.4. If the measured input

 

 

 

 

 

 

current is not within spec (see

 

 

 

 

 

 

Tables 9-11), check CCR,

 

 

 

 

 

 

isolation transformer, and

 

 

 

 

 

 

primary power connections.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

Image 15
Contents Airside Guidance Sign AGS-LED LED Series Sizes 1, 2, 3, 4 Revisions Limited Product Warranty Keep Away from Live Circuits Safety NoticesDocument REV. B AGS-LED Test Equipment and Tools Table of Contents Double module sign List of Figures and TablesClassification of Signs General Information General DescriptionPart Numbers LED Series Document REV. B AGS-LED Document REV. B AGS-LED 5345-44J Proprietary process replacement panels meet the photommetricMax. See F igure 18 Also, remover carriers from thermmal pad Adhesive surfaces before installingProblem Possible Cause Corrective Action CCR Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Continue Checking the Rest of the LED Modules Replacing an LED Moddule Document REV. B AGS-LED Sign PC Board P/N 62277 Calibration Replacing Sign Power Supply Board & Heat Sink P/NDocument REV. B AGS-LED Document REV. B AGS-LED Figures and Tables Document 1025 REV. B Three module sign Four module sign Distance Marker Sign Options Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Expanded left section of Figure Expanded right section of Figure Expanded top section of Figure Concrete Foundation/Pad configurations, Size Concrete Foundation/Pad configurations, Size Document REV. B AGS-LED Sizes 3, & 5 Concrete Foundation/Pad Configurations Size 4 Concrete Foundation/Pad Configurations Power Supply Box Power Supply Wiring Diagram Documment REV. B AGS-LED Power Supply Switch and Jumper Selection Ferro CCR Power Supply Switch and Jumper Selection Series CCR Cchalp Cchalp Style Sign Size # Modules CCR type @5.5A Xfrmr Type Series 181 Sign Sign VA Watts Power Sign Watts 108 Regulator Setting Current Range A, RMS D11 D29 Fault Red Part Description Number Used on Document