5Test Equipment and Tools

There is a wide variety of tools and equipment needed to safely and correctly perform airfield lighting equipment installation and maintenance. In addition to the obvious tools (screwdrivers, wrenches, etc.), there is a specialized equipment needed to do the job.

Multimeter

One of the most important pieces of test equipment is the Multimeter. It is used to measure voltages, currents, and resistances. Almost every single maintenance task requires the use of a multimeter at one point or another. A quality meter in good repair and calibration is a must because airfield lighting power distribution equipment produces non-sinusoidal waveforms, traditional average reading meters are inaccurate and have very limited use. Checking or adjusting equipment based upon incorrect current reading may dramatically reduce lamp life and adversely affect power equipment performance. A meter with TRUE RMS measuring capability and a current clamp-on probe is needed to accurately measure distorted or chopped waveforms. All meter manufacturers offer TRUE RMS measuring meters. The following is a short list of TRUE RMS Multimeters from Fluke:

Manufacturer

Model Number

 

 

Fluke

87V, 287

 

 

Our recommended meter is the Fluke 87V with the Fluke I800 current clamp.

Refer to the equipment manufacturer’s manuals for the proper use, maintenance and calibration (if necessary) of all meters.

vi

Image 6
Contents Airside Guidance Sign AGS-LED LED Series Sizes 1, 2, 3, 4 Revisions Limited Product Warranty Safety Notices Keep Away from Live CircuitsDocument REV. B AGS-LED Test Equipment and Tools Table of Contents List of Figures and Tables Double module signGeneral Information General Description Classification of SignsPart Numbers LED Series Document REV. B AGS-LED Document REV. B AGS-LED Proprietary process replacement panels meet the photommetric 5345-44JAdhesive surfaces before installing Max. See F igure 18 Also, remover carriers from thermmal padProblem Possible Cause Corrective Action CCR Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Continue Checking the Rest of the LED Modules Replacing an LED Moddule Document REV. B AGS-LED Replacing Sign Power Supply Board & Heat Sink P/N Sign PC Board P/N 62277 CalibrationDocument REV. B AGS-LED Document REV. B AGS-LED Figures and Tables Document 1025 REV. B Three module sign Four module sign Distance Marker Sign Options Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Document REV. B AGS-LED Expanded left section of Figure Expanded right section of Figure Expanded top section of Figure Concrete Foundation/Pad configurations, Size Concrete Foundation/Pad configurations, Size Document REV. B AGS-LED Sizes 3, & 5 Concrete Foundation/Pad Configurations Size 4 Concrete Foundation/Pad Configurations Power Supply Box Power Supply Wiring Diagram Documment REV. B AGS-LED Power Supply Switch and Jumper Selection Ferro CCR Power Supply Switch and Jumper Selection Series CCR Cchalp Cchalp Style Sign Size # Modules CCR type @5.5A Xfrmr Type Series 181 Sign Sign VA Watts Power Sign Watts 108 Regulator Setting Current Range A, RMS D11 D29 Fault Red Part Description Number Used on Document